Foreign body (FB) ingestion is a common clinical problem in acute settings. Detecting FBs in the upper digestive tract is challenging. The conventional X-ray is usually the first-line imaging tool to detect FBs. However, its diagnostic performance is inconsistent in the literature. In this study, we performed a systematic review and meta-analysis to determine the diagnostic performance of the conventional X-ray for detecting FBs in the upper digestive tract. We conducted a systematic search of PubMed, Embase, Cochrane Library, Web of Science, and Scopus until 1 August 2020. Prospective or retrospective studies investigating the diagnostic accuracy of conventional X-rays for detecting FBs in the upper digestive tract in patients of all ages were included. The Quality Assessment of Studies of Diagnostic Accuracy-2 tool was used to review the quality of included studies. We used a bivariate random-effects model to calculate diagnostic accuracy parameters. Heterogeneity was assessed using I2 statistics. We included 17 studies (n = 4809) in the meta-analysis. Of the 17 studies, most studies were rated as having a high risk of bias. Conventional X-rays had a pooled sensitivity of 0.58 (95% confidence interval [CI] = 0.36–0.77, I2 = 98.52) and a pooled specificity of 0.94 (95% CI = 0.87–0.98, I2 = 94.49) for detecting FBs in the upper digestive tract. The heterogeneity was considerable. The area under the summary receiver operating characteristic curve was 0.91 (95% CI = 0.88–0.93). Deek’s funnel plot asymmetry test results revealed no significant publication bias (p = 0.41). The overall sensitivity and specificity of conventional X-rays were low and high, respectively, for detecting FBs in the upper digestive tract. Hence, conventional X-rays to exclude patients without upper FBs in the digestive tract are not recommended. Further imaging or endoscopic examinations should be performed for at-risk patients.
Return of spontaneous circulation (ROSC) from out-of-hospital cardiac arrest (OHCA) is critical for the Emergency Medical Services System. When compared to other developed countries, Taiwan has lower rate of ROSC in OHCA patients. We conducted a retrospective study of cardiac arrest using The Emergency Medical Service Dispatching Center in Northern Taiwan and The Prehospital Care System of New Taipei City Paramedic Service. Patients suffering from nontraumatic OHCA between August of 2019 to February of 2020 were included. We analyzed the cardiopulmonary resuscitation (CPR) quality parameters such as chest compression interruptions, bystander CPR, shockable rhythm, CPR interruption, chest compression fraction (CCF) average, patient transportation in buildings, and adrenaline injection during CPR. Multivariable logistic regression analysis was performed to assess the relationship between potential independent variables and ROSC. In our study, we involved 1265 subjects suffering from nontraumatic OHCA, among which 587 patients met inclusion criteria. We identified that CCF> 0.8, chest compression interruption greater than 3 times, and patient transportation in the building were the most critical factors influencing ROSC. However, patient transportation in a building was identified as a dependent predictor variable (P = .4752). We concluded that CCF > 0.8 and chest compression interruption greater than 3 times were essential factors affecting the CPR ROSC rate. The most significant reason for suboptimal CCF and CPR interruption is patient transportation in a building. Improving the latter point could facilitate high-quality CPR.