Steve Warren

Dr. Steve Warren

Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Charles CarlsonCharles Carlson
Charles Carlson
VTVanessa-Rose Turpin
Vanessa-Rose Turpin
Ahmad SulimanAhmad Suliman
Ahmad Suliman
CACarl Ade
Carl Ade
Steve WarrenSteve Warren
Steve Warren
David E. ThompsonDavid E. Thompson
David E. Thompson
Background: The goal of this work was to create a sharable dataset of heart-driven signals, including ballistocardiograms (BCGs) and time-aligned electrocardiograms (ECGs), photoplethysmograms (PPGs), and blood pressure waveforms. Methods: A custom, bed-based ballistocardiographic system is described in detail. Affiliated cardiopulmonary signals are acquired using a GE Datex CardioCap 5 patient monitor (which collects ECG and PPG data) and a Finapres Medical Systems Finometer PRO (which provides continuous reconstructed brachial artery pressure waveforms and derived cardiovascular parameters). Results: Data were collected from 40 participants, 4 of whom had been or were currently diagnosed with a heart condition at the time they enrolled in the study. An investigation revealed that features extracted from a BCG could be used to track changes in systolic blood pressure (Pearson correlation coefficient of 0.54 +/− 0.15), dP/dtmax (Pearson correlation coefficient of 0.51 +/− 0.18), and stroke volume (Pearson correlation coefficient of 0.54 +/− 0.17). Conclusion: A collection of synchronized, heart-driven signals, including BCGs, ECGs, PPGs, and blood pressure waveforms, was acquired and made publicly available. An initial study indicated that bed-based ballistocardiography can be used to track beat-to-beat changes in systolic blood pressure and stroke volume. Significance: To the best of the authors’ knowledge, no other database that includes time-aligned ECG, PPG, BCG, and continuous blood pressure data is available to the public. This dataset could be used by other researchers for algorithm testing and development in this fast-growing field of health assessment, without requiring these individuals to invest considerable time and resources into hardware development and data collection.

1 December 2005 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
JYJianchu Yao
Jianchu Yao
Steve WarrenSteve Warren
Steve Warren

13 May 2004
Verified
Conference Paper
Open access
LNL. Nagl
L. Nagl
RSR. Schmitz
R. Schmitz
Steve WarrenSteve Warren
Steve Warren
THT.S. Hildreth
T.S. Hildreth
HEH. Erickson
H. Erickson
DAD. Andresen
D. Andresen

15 July 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
AAAlaleh Alivar
Alaleh Alivar
Charles CarlsonCharles Carlson
Charles Carlson
Ahmad SulimanAhmad Suliman
Ahmad Suliman
Steve WarrenSteve Warren
Steve Warren
PPPunit Prakash
Punit Prakash
BNBalasubramaniam (Bala) Natarajan
Balasubramaniam (Bala) Natarajan
Monitoring the sleep patterns of children with autism spectrum disorders (ASD) and understanding how sleep quality influences their daytime behavior is an important issue that has received very limited attention. Polysomnography (PSG) is commonly used as a gold standard for evaluating sleep quality in children and adults. However, the intrusive nature of sensors used as part of PSG can themselves affect sleep and is, therefore, not suitable for children with ASD. In this study, we evaluate an unobtrusive and inexpensive bed system for in-home, long-term sleep quality monitoring using ballistocardiogram (BCG) signals. Using the BCG signals from this smart bed system, we define "restlessness" as a surrogate sleep quality estimator. Using this sleep feature, we build predictive models for daytime behavior based on 1-8 previous nights of sleep. Specifically, we use two supervised machine learning algorithms namely support vector machine (SVM) and artificial neural network (ANN). For all daytime behaviors, we achieve more than 78% and 79% accuracy of correctly predicting behavioral issues with both SVM and ANN classifiers, respectively. Our findings indicate the usefulness of our designed bed system and how the restlessness feature can improve the prediction performance.

1 August 2008
Verified
Conference Paper
Closed access
RKRajet Krishnan
Rajet Krishnan
BNBalasubramaniam (Bala) Natarajan
Balasubramaniam (Bala) Natarajan
Steve WarrenSteve Warren
Steve Warren
Corruption of photopleythsmograms by motion artifacts has been a serious obstacle to the reliable use of pulse oximeters for real-time, continuous state-of-health monitoring. In this work, we propose a motion artifact reduction methodology that is effective even in the case of severe subject movement. The methodology involves an enhanced preprocessing unit consisting of a motion detection unit (MDU), period estimation unit, and a Fourier series reconstruction unit. The MDU aids in identifying clean data frames versus those corrupted with motion artifacts. The period detection unit is used to determine the fundamental frequency of a corrupt frame. The Fourier series reconstruction unit reconstructs the final preprocessed signal. The reconstruction process primarily utilizes the spectrum variability of the pulse waveform. Preprocessed data are then fed to a magnitude- based frequency domain independent component analysis (FD-ICA) unit. This helps reduce motion artifacts present at the frequency components chosen for reconstruction. Experimental results are presented to demonstrate the effectiveness of the proposed motion artifact reduction method. The efficacy of the technique is compared with time domain ICA and complex frequency domain ICA methods.

1 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmad SulimanAhmad Suliman
Ahmad Suliman
Md Rakibul MowlaMd Rakibul Mowla
Md Rakibul Mowla
AAAlaleh Alivar
Alaleh Alivar
Charles CarlsonCharles Carlson
Charles Carlson
PPPunit Prakash
Punit Prakash
DTDavid E. Thompson
David E. Thompson
Heart rate variability (HRV) features support several clinical applications, including sleep staging, and ballistocardiograms (BCGs) can be used to unobtrusively estimate these features. Electrocardiography is the traditional clinical standard for HRV estimation, but BCGs and electrocardiograms (ECGs) yield different estimates for heartbeat intervals (HBIs), leading to differences in calculated HRV parameters. This study examines the viability of using BCG-based HRV features for sleep staging by quantifying the impact of these timing differences on the resulting parameters of interest. We introduced a range of synthetic time offsets to simulate the differences between BCG- and ECG-based heartbeat intervals, and the resulting HRV features are used to perform sleep staging. Subsequently, we draw a relationship between the mean absolute error in HBIs and the resulting sleep-staging performances. We also extend our previous work in heartbeat interval identification algorithms to demonstrate that our simulated timing jitters are close representatives of errors between heartbeat interval measurements. This work indicates that BCG-based sleep staging can produce accuracies comparable to ECG-based techniques such that at an HBI error range of up to 60 ms, the sleep-scoring error could increase from 17% to 25% based on one of the scenarios we examined.