Seyedabdollah Mirbozorgi

Dr. Seyedabdollah Mirbozorgi

Department of Electrical and Computer Engineering, University of Alabama at Birmingham (UAB), BEC 259D, 1150 10th Ave South, Birmingham, AL 35294
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Saeideh PahlavanSaeideh Pahlavan
Saeideh Pahlavan
SAShahin Jafarabadi Ashtiani
Shahin Jafarabadi Ashtiani
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
This paper presents an innovative T/Y-maze-based wireless power transmission (WPT) system designed to monitor spatial reference memory and learning behavior in freely moving rats. The system facilitates uninterrupted optical/electrical stimulation and neural recording experiments through the integration of wireless headstages or implants in T/Y maze setups. Utilizing an array of resonators covering the entire underneath of the mazes, the wireless platform ensures scalability with various configurations. The array is designed to ensure a natural localization mechanism to localize the Tx power toward the location of the Rx coil. The system is analyzed and modeled using ANSYS HFSS software to optimize design. The primary goal was to achieve uniform wireless power delivery throughout the mazes through a comparative study of different transmitter (Tx) array configurations, such as float, series, and parallel resonators. The calculated Specific Absorption Rate (SAR) in rat tissue model equals 1.7 W/kg at the power carrier frequency of 13.56 MHz. A prototype of the proposed maze-based WPT design, featuring 8 Tx resonators, a Tx coil and power amplifier, and a headstage power harvesting unit, is successfully implemented and its performance characterized for all three resonator configurations. The implemented T maze-based WPT system has a total length of 128 cm. In the overlapping Tx resonators configuration, a homogeneity of 94% is achieved for the measured power transfer efficiency at over 30%, while continuously delivering over 60 mW for series configuration.

11 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
RSReepa Saha
Reepa Saha
ZKZohreh Kaffash
Zohreh Kaffash
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
This paper presents a novel resonance-based, adaptable, and flexible inductive wireless power transmission (WPT) link for powering implantable and wearable devices throughout the human body. The proposed design provides a comprehensive solution for wirelessly delivering power, sub-micro to hundreds of milliwatts, to deep-tissue implantable devices (3D space of human body) and surface-level wearable devices (2D surface of human skin) safely and seamlessly. The link comprises a belt-fitted transmitter (Belt-Tx) coil equipped with a power amplifier (PA) and a data demodulator unit, two resonator clusters (to cover upper-body and lower-body), and a receiver (Rx) unit that consists of Rx load and resonator coils, rectifier, microcontroller, and data modulator units for implementing a closed-loop power control (CLPC) mechanism. All coils are tuned at 13.56 MHz, Federal Communications Commission (FCC)-approved industrial, scientific, and medical (ISM) band. Novel customizable configurations of resonators in the clusters, parallel for implantable devices and cross-parallel for wearable devices and vertically oriented implants, ensure uniform power delivered to the load, PDL, enabling natural Tx power localization toward the Rx unit. The proposed design is modeled, simulated, and optimized using ANSYS HFSS software. The Specific Absorption Rate (SAR) is calculated under 1.5 W/kg, indicating the design’s safety for the human body. The proposed link is implemented, and its performance is characterized. For both the parallel cluster (implant) and cross-parallel cluster (wearable) scenarios, the measured results indicate: 1) an upper-body PDL exceeding 350 mW with a Power Transfer Efficiency (PTE) reaching 25%, and 2) a lower-body PDL surpassing 360 mW with a PTE of up to 20%, while covering up to 92% of the human body.

1 December 2020 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
EMEsmaeel Maghsoudloo
Esmaeel Maghsoudloo
HBHadi Bahrami
Hadi Bahrami
MSMohamad Sawan
Mohamad Sawan
Benoit GosselinBenoit Gosselin
Benoit Gosselin
This study presents the design of efficient wireless power distribution systems based on resonant inductive arrays. The authors show how to use multi‐resonator arrays to charge and power up several electric devices in parallel, with nearly constant transmitted power, and using a single power source. Their single‐source wireless power transmission clusters, for instance, are shown to provide free positioning at better power efficiency than previous solutions. They provide analysis, simulation, and measurement performance of their multi‐resonator arrays, they compare them with other types of inductive arrays employed into different schemes (multi‐coil inductive links, overlapping and non‐overlapping links), and they show the advantage of their strategy over previous solutions. The presented wireless power distribution systems improve power transmission efficiency (PTE) in free positioning by as much as 30%. The measured results show that their multi‐resonator arrays present significant advantages: (i) they allow multiple charging zones from a single power source; (ii) they provide free positioning with strictly uniform power delivered to the load; and (iii) they provide superior efficiency through a built‐in power localization mechanism, which is not available in other solutions. The PTE of the multi‐resonator array in single‐receiver and multi‐receiver configurations outperformed previous solutions by 26% and 12%, respectively.

25 February 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
HZHossein Zangooei
Hossein Zangooei
SMSeyed Ali Mirbozorgi
Seyed Ali Mirbozorgi
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
Implantable devices, ultrasound imaging catheters, and ablation catheters (such as renal denervation catheters) are biomedical instruments that generate heat in the body. The generated heat can be harmful if the body temperature exceeds the limit of almost 315 K. This paper presents a heat-transfer model and analysis, to evaluate the temperature rise in human blood due to the power loss of medical catheters and implantable devices. The dynamic of the heat transfer is modeled for the blood vessel, at different blood flow velocities. The physics and governing equations of the heat transfer from the implanted energy source to the blood and temperature rise are expressed by developing a Non-Newtonian Carreau–Yasuda fluid model. We used a Finite Element method to solve the governing equations of the established model, considering the boundary conditions and average blood flow velocities of 0–1.4 m/s for the flow of the blood passing over the implanted power source. The results revealed a maximum allowable heat flux of 7500 and 15,000 W/m2 for the blood flow velocities of 0 and 1.4 m/s, respectively. The rise of temperature around the implant or tip of the catheter is slower and disappeared gradually with the blood flow, which allows a higher level of heat flux to be generated. The results of this analysis are concluded in the equation/correlation T=310+H3000(1+e−7V), to estimate and predict the temperature changes as a function of heat flux, H, and the blood flow velocity, V, at the implant/catheter location.

6 March 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LDLarry Duncan
Larry Duncan
SZShaotong Zhu
Shaotong Zhu
MPMackenzi Pergolotti
Mackenzi Pergolotti
SGSmith Giri
Smith Giri
HSHoda Salsabili
Hoda Salsabili
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
This paper presents an automatic camera-based device to monitor and evaluate the gait speed, standing balance, and 5 Times Sit-Stand (5TSS) tests of the Short Physical Performance Battery (SPPB) and the Timed Up and Go (TUG) test. The proposed design measures and calculates the parameters of the SPPB tests automatically. The SPPB data can be used for physical performance assessment of older patients under cancer treatment. This stand-alone device has a Raspberry Pi (RPi) computer, three cameras, and two DC motors. The left and right cameras are used for gait speed tests. The center camera is used for standing balance, 5TSS, and TUG tests and for angle positioning of the camera platform toward the subject using DC motors by turning the camera left/right and tilting it up/down. The key algorithm for operating the proposed system is developed using Channel and Spatial Reliability Tracking in the cv2 module in Python. Graphical User Interfaces (GUIs) in the RPi are developed to run tests and adjust cameras, controlled remotely via smartphone and its Wi-Fi hotspot. We have tested the implemented camera setup prototype and extracted all SPPB and TUG parameters by conducting several experiments on a human subject population of 8 volunteers (male and female, light and dark complexions) in 69 test runs. The measured data and calculated outputs of the system consist of tests of gait speed (0.041 to 1.92 m/s with average accuracy of >95%), and standing balance, 5TSS, TUG, all with average time accuracy of >97%.

12 June 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
RSReepa Saha
Reepa Saha
LJLe Jiang
Le Jiang
HSHoda Salsabili
Hoda Salsabili
Miad FaezipourMiad Faezipour
Miad Faezipour
SOSarah Ostadabbas
Sarah Ostadabbas
Seyedabdollah MirbozorgiSeyedabdollah Mirbozorgi
Seyedabdollah Mirbozorgi
This paper presents a highly scalable and rack-mountable wireless sensing system for long-term monitoring (i.e., sense and estimate) of small animal/s' physical state (SAPS), such as changes in location and posture within standard cages. The conventional tracking systems may lack one or more features such as scalability, cost efficiency, rack-mount ability, and light condition insensitivity to work 24/7 on a large scale. The proposed sensing mechanism relies on relative changes of multiple resonance frequencies due to the animal's presence over the sensor unit. The sensor unit can track SAPS changes based on changes in electrical properties in the sensors near fields, appearing in the resonance frequencies, i.e., an Electromagnetic (EM) Signature, within the 200 MHz - 300 MHz frequency range. The sensing unit is located underneath a standard mouse cage and consists of thin layers of a reading coil and six resonators tuned at six distinct frequencies. ANSYS HFSS software is used to model and optimize the proposed sensor unit and calculate the Specific Absorption Rate (SAR) obtained under 0.05 W/kg. Multiple prototypes have been implemented to test, validate, and characterize the performance of the design by conducting in vitro and in vivo experiments on Mice. The in-vitro test results have shown a 15 mm spatial resolution in detecting the mouse's location over the sensor array having maximum frequency shifts of 832 kHz and posture detection with under 30º resolution. The in-vivo experiment on mouse displacement resulted in frequency shifts of up to 790 kHz, indicating the SAPS's capability to detect the Mice's physical state.