Bryson Carrier

Mr. Bryson Carrier

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2020 in Technologies
Verified
Journal Article
Open access
PDF file
BCBryson Carrier
Bryson Carrier
BBBrenna Barrios
Brenna Barrios
BJBrayden D. Jolley
Brayden D. Jolley
James W NavaltaJames W Navalta
James W Navalta
The purpose of this review was to evaluate the current state of the literature and to identify the types of study designs, wearable devices, statistical tests, and exercise modes used in validation and reliability studies conducted in applied settings/outdoor environments. This was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. We identified nine articles that fit our inclusion criteria, eight of which tested for validity and one tested for reliability. The studies tested 28 different devices with exercise modalities of running, walking, cycling, and hiking. While there were no universally common analytical techniques used to measure accuracy or validity, correlative measures were used in 88% of studies, mean absolute percentage error (MAPE) in 75%, and Bland–Altman plots in 63%. Intra-class correlation was used to determine reliability. There were not any universally common thresholds to determine validity, however, of the studies that used MAPE and correlation, there were only five devices that had a MAPE of < 10% and a correlation value of > 0.7. Overall, the current review establishes the need for greater testing in applied settings when validating wearables. Researchers should seek to incorporate multiple intensities, populations, and modalities into their study designs while utilizing appropriate analytical techniques to measure and determine validity and reliability.

6 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BCBryson Carrier
Bryson Carrier
SCSofia Marten Chaves
Sofia Marten Chaves
James W NavaltaJames W Navalta
James W Navalta
Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool. Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22). VO2max was assessed through a graded exercise test and an outdoor run, comparing results from the Garmin fēnix 6 to a criterion measurement obtained from a metabolic system. Pulse oximetry involved comparing fēnix 6 readings under normoxic and hypoxic conditions against a medical-grade pulse oximeter. Data analysis included descriptive statistics, error analysis, correlation analysis, equivalence testing, and bias assessment, with the validation criteria set at a concordance correlation coefficient (CCC) > 0.7 and a mean absolute percentage error (MAPE) < 10%. Results: The Garmin fēnix 6 provided accurate VO2max estimates, closely aligning with the 15 s and 30 s averaged laboratory data (MAPE for 30 s avg = 7.05%; Lin’s concordance correlation coefficient for 30 s avg = 0.73). However, it failed to accurately measure blood oxygen saturation (BOS) under any condition or combined analysis (MAPE for combined conditions BOS = 4.29%; Lin’s concordance correlation coefficient for combined conditions BOS = 0.10). Conclusion: While the Garmin fēnix 6 shows promise for estimating the VO2max, reflecting its utility for both individuals and researchers, it falls short in accurately measuring BOS, limiting its application for monitoring acclimatization and managing pulmonary diseases. This research underscores the importance of validating wearable technology to leverage its full potential in enhancing personal health and advancing public health research.

1 January 2022 in International Journal of Exercise Science
Verified
Journal Article
Open access
PDF file
DDDustin Wyatt Davis
Dustin Wyatt Davis
BCBryson Carrier
Bryson Carrier
KCKyle Cruz
Kyle Cruz
BBBrenna Barrios
Brenna Barrios
MLMerrill Russen Landers
Merrill Russen Landers
James W NavaltaJames W Navalta
James W Navalta
International Journal of Exercise Science 15(2): 1692-1734, 2022. Meditative and mindful exercise are types of physical exercise during which people pay attention, on purpose, to each new present moment without judging their experience. The goal is to apply an accepting awareness of the environment, bodily sensations, thoughts, and emotions without labeling them (e.g., good or bad). The literature centers on qigong, tai chi, and yoga, which are types of mindful exercise that improve mental and cardiovascular health. It is unclear if meditative and mindful walking also improve these health domains. To the authors’ knowledge, this question has not been addressed by a published systematic review. The purpose of this systematic review without a meta-analysis was to synthesize the literature on meditative and mindful walking to determine their effects on mental and cardiovascular health. The protocol follows the PRISMA guidelines, is registered in PROSPERO (CRD42021241180), and is published elsewhere in a peer-reviewed journal. The systematic review contains 14 studies that had various populations, interventions, and outcomes. In 13 studies, the interventions statistically significantly improved scores on at least one outcome of mental or cardiovascular health (e.g., affect, anxiety, depression, distress, state mindfulness, stress, blood pressure, and six-minute walk distance). The improved outcomes should be interpreted cautiously because their clinical meaningfulness is unclear, and the studies had severe methodological limitations. Determining if meditative and mindful walking meaningfully improve mental and cardiovascular health will require randomized controlled trials that use rigorous designs, transparent protocols, and clinically meaningful outcomes that indicate physical function, mental wellbeing, morbidity, and mortality.

17 June 2023 in Technologies
Verified
Journal Article
Open access
PDF file
CGClinton Gardner
Clinton Gardner
James W NavaltaJames W Navalta
James W Navalta
BCBryson Carrier
Bryson Carrier
CACharli Aguilar
Charli Aguilar
JRJorge Perdomo Rodriguez
Jorge Perdomo Rodriguez
Methods: Training impulse (TRIMP) is obtained through wearable technology and plays a direct role on the load management of soccer players. It is important to understand TRIMP to best prepare athletes for competition. A systematic search for articles was conducted using Google Scholar, with papers screened and extracted by five reviewers. The inclusion criteria were: the study was focused on collegiate or professional soccer, the use of training impulse (TRIMP), and the use of wearable technology to measure TRIMP. Of 10,100 papers, 10,090 articles were excluded through the systematic review process. Ten papers were selected for final review and grouped based on (1) training vs. match (N = 8/10), (2) preseason vs. in-season (N = 3/10), and (3) positional comparison (N = 3/10). Wearable technologies mainly track physical metrics (N = 10/10). Higher TRIMP data were noted in starters than reserves throughout the season in matches and slightly lower TRIMP for starters vs. reserves during training. TRIMP data change throughout the season, being higher in preseason phases compared to early-season, mid-season, and late-season phases. These findings help highlight the benefits of TRIMP in managing internal player load in soccer. Future research should focus on utilizing wearable-derived TRIMP and the impact on player performance metrics, and how TRIMP data vary across different positions in soccer.

26 May 2023 in Technologies
Verified
Journal Article
Open access
PDF file
BCBryson Carrier
Bryson Carrier
MHMacy M. Helm
Macy M. Helm
KCKyle Cruz
Kyle Cruz
BBBrenna Barrios
Brenna Barrios
James W NavaltaJames W Navalta
James W Navalta
As wearable technology (WT) has evolved, devices have developed the ability to track a range of physiological variables. These include maximal aerobic capacity (VO2max) and lactate threshold (LT). With WT quickly growing in popularity, independent evaluation of these devices is important to determine the appropriate use-cases for the devices. Therefore, the purpose of this study was to determine the validity of WT in producing estimates of VO2max and LT in athletic populations. METHODS: 21 participants completed laboratory LT and VO2max testing, as well as an outdoor testing session guided by the WT being tested (Garmin fēnix 6® watch and accompanying heart rate monitor). Statistical analysis was completed, using hypothesis testing (ANOVA, t-test), correlation analysis (Pearson’s r, Lin’s Concordance Correlation [CCC]), error analysis (mean absolute percentage error [MAPE]), equivalence testing (TOST test), and bias assessment (Bland–Altman analysis). RESULTS: The Garmin watch was found to have acceptable agreement for VO2max when compared to the 1 min averaged values (MAPE = 6.85%, CCC = 0.7) and for LT and the onset of blood lactate accumulation (OBLA), (MAPE = 7.52%, CCC = 0.79; MAPE = 8.20%, CCC = 0.74, respectively). Therefore, the Garmin fēnix 6® produces accurate measurements of VO2max and LT in athletic populations and can be used to make training decisions among athletes.

28 August 2024 in Sports
Verified
Journal Article
Open access
PDF file
James W NavaltaJames W Navalta
James W Navalta
BCBryson Carrier
Bryson Carrier
MBMatahn Blank
Matahn Blank
SZSetareh Zarei
Setareh Zarei
DDDustin Wyatt Davis
Dustin Wyatt Davis
JBJamaal Bovell
Jamaal Bovell
Pickleball is a popular sport. Also popular is wearable technology usage. Because the validity and reliability of wearable technology during pickleball is unknown, the purpose of this research was to evaluate the ability of common devices to return heart rate and estimated energy expenditure during pickleball activity. Twenty adult participants were outfitted with a portable metabolic unit and heart rate monitor (criterion measures). Experimental devices were a Garmin Instinct, Polar Vantage M2, Polar OH1, and Polar Verity Sense. Participants played simulated pickleball for 10 min. Validity measures included mean absolute percent error (MAPE) and Lin’s Concordance Correlation Coefficient (CCC), whereas reliability measures included coefficient of variation (CV) and intraclass correlation coefficient (ICC). The heart rate returned lower than 10% MAPE across all devices (Instinct = 5.73–6.32%, Verity Sense = 2.92–2.97%, OH1 = 3.39–3.45%) and greater than 0.85 CCC (Instinct = 0.85–0.88, Verity Sense = 0.96–0.96, OH1 = 0.93–0.94). The CV was below 10% (Instinct = 9.30%, Verity Sense = 2.68%, OH1 = 5.01%), and ICC was above 0.7 (Instinct = 0.77, Verity Sense = 0.98, OH1 = 0.91). The energy expenditure MAPE was greater than 10% (Instinct = 27.67–28.08%, Vantage M2 = 18.87–23.38%) with CCC lower than 0.7 (Instinct = 0.47–0.49, Vantage M2 = 0.62–0.63). Reliability thresholds were met in the Vantage M2 (CV = 6%, ICC = 0.98) but not in the Instinct (CV = 15%, ICC = 0.86). The Instinct was neither valid nor reliable for estimated energy expenditure, while the Polar Vantage M2 was reliable but not valid. All devices returned valid and reliable heart rates during pickleball.