Tao Li

Dr. Tao Li

Sichuan University
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2023 in Thin-Walled Structures
Verified
Journal Article
Closed access
KDKaoshan Dai
Kaoshan Dai
TSTongfei Sun
Tongfei Sun
YLYe Liu
Ye Liu
Tao LiTao Li
Tao Li
ACAlfredo Camara
Alfredo Camara

1 September 2017 in Engineering Structures
Verified
Journal Article
Closed access
Tao LiTao Li
Tao Li
JBJeffrey W. Berman
Jeffrey W. Berman
RWRichard Wiebe
Richard Wiebe

22 September 2022 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
Tao LiTao Li
Tao Li
YYYijian Yang
Yijian Yang
JXJun Xu
Jun Xu
KDKaoshan Dai
Kaoshan Dai
QGQingzi Ge
Qingzi Ge
ZHZhenhua Huang
Zhenhua Huang

21 July 2020 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
HAHayato Asada
Hayato Asada
ASAndrew D. Sen
Andrew D. Sen
Tao LiTao Li
Tao Li
JBJeffrey W. Berman
Jeffrey W. Berman
DLDawn E. Lehman
Dawn E. Lehman
CRCharles W. Roeder
Charles W. Roeder

17 February 2023 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
JWJianze Wang
Jianze Wang
WCWeiwei Chen
Weiwei Chen
KDKaoshan Dai
Kaoshan Dai
Tao LiTao Li
Tao Li
STSolomon Tesfamariam
Solomon Tesfamariam
YLYang Lu
Yang Lu

14 December 2020 in Buildings
Verified
Journal Article
Open access
PDF file
FAFrancisco López Almansa
Francisco López Almansa
DWDagen Weng
Dagen Weng
Tao LiTao Li
Tao Li
BABashar Alfarah
Bashar Alfarah
Base (seismic) isolation is a promising technology for seismic protection of buildings and other constructions. Nowadays, it is accepted that such a technique is efficient and reliable; however, it has two major limitations: soft foundation soil, and tall buildings. The first issue restrains the seismic isolation spreading, given that soft soil is frequent in densely populated areas, and usually such a soil type concentrates the highest seismicity levels. This paper aims to contribute to demonstrating that base isolation, if properly implemented, can be suitable for soft soil. A representative case study is analyzed: a 6-story reinforced concrete (RC) building with base isolation that has recently been built in Shanghai. Since the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, non-linear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity; the superstructure behavior is linear, while nonlinearities are concentrated in the isolation layer. The adequacy of base isolation is assessed in the superstructure (in terms of reduction of interstory drift, absolute acceleration and shear force) and in the isolation layer (in terms of axial force, torsion angle and shear strain). The relevance of soil–structure interaction is discussed. The behavior when the mechanical parameters of the isolation units have experienced important changes is also analyzed. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.