David Sonnenfroh

Dr. David Sonnenfroh


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2001 in Applied Optics
Verified
Journal Article
Closed access
PDF file
DSDavid Sonnenfroh
David Sonnenfroh
WRW. Terry Rawlins
W. Terry Rawlins
MAMark G. Allen
Mark G. Allen
CGClaire Gmachl
Claire Gmachl
FCFederico Capasso
Federico Capasso
ACAlfred Y. Cho
Alfred Y. Cho
Distributed-feedback quantum-cascade (QC) lasers are expected to form the heart of the next-generation mid-IR laser absorption spectrometers, especially as they are applied to measurements of trace gases in a variety of environments. The incorporation of room-temperature-operable, single-mode QC lasers should result in highly compact and rugged sensors for real-world applications. We report preliminary results on the performance of a laser absorption spectrometer that uses a QC laser operating at room temperature in a quasi-cw mode in conjunction with balanced ratiometric detection. We have demonstrated sensitivities for N2O [10 parts in 106 volume-mixing ratio for a 1-m path (ppmv-m)] and NO [520 parts in 109 volume-mixing ratio for a 1-m path (ppbv-m)] at 5.4 µm. System improvements are described that are expected to result in a 2 orders of magnitude increase in sensitivity.

1 September 1998 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
DSDavid Sonnenfroh
David Sonnenfroh
WKW.J. Kessler
W.J. Kessler
JMJ.C. Magill
J.C. Magill
BUB.L. Upschulte
B.L. Upschulte
MAM.G. Allen
M.G. Allen
JBJ.D.W. Barrick
J.D.W. Barrick

1 November 2005 in Applied Optics
Verified
Journal Article
Closed access
PDF file
WRWilson T. Rawlins
Wilson T. Rawlins
JHJoel M. Hensley
Joel M. Hensley
DSDavid Sonnenfroh
David Sonnenfroh
DODavid B. Oakes
David B. Oakes
MAMark G. Allen
Mark G. Allen
We have demonstrated a high-sensitivity, room-temperature quantum-cascade (QC) laser sensor for detection of SO2 and SO3 under conditions relevant to aircraft test combustor exhaust. Two QC lasers probe infrared absorption features at 7.50 and 7.16 μm for SO2 and SO3, respectively, with a common dual-beam detection system. We inferred a noise-equivalent absorbance of ~1 × 10−4 Hz−1/2. We have demonstrated detection limits for both SO2 and SO3 of 1–2 ppmv m/Hz1/2 (where ppmv is parts in 106 by volume) for 300 torr, elevated temperature, and path lengths near 1 m. This level of sensitivity permits measurement of <1 ppmv of SO2 and SO3 at these conditions with modest signal averaging.

28 August 2015 in Sensors
Verified
Journal Article
Open access
PDF file
GPGenevieve Plant
Genevieve Plant
MNMichal Nikodem
Michal Nikodem
PMPhil Mulhall
Phil Mulhall
RVRuth K. Varner
Ruth K. Varner
DSDavid Sonnenfroh
David Sonnenfroh
GWGerard Wysocki
Gerard Wysocki
Existing technologies for quantifying methane emissions are often limited to single point sensors, making large area environmental observations challenging. We demonstrate the operation of a remote, multi-path system using Chirped Laser Dispersion Spectroscopy (CLaDS) for quantification of atmospheric methane concentrations over extended areas, a technology that shows potential for monitoring emissions from wetlands.

11 January 1993
Verified
Conference Paper
Closed access
MAM. Allen
M. Allen
JCJ. Cronin
J. Cronin
SDS. Davis
S. Davis
RFR. Foutter
R. Foutter
TPT. Parker
T. Parker
DSDavid Sonnenfroh
David Sonnenfroh

6 November 2010 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
DSDavid Sonnenfroh
David Sonnenfroh
KPK. Parameswaran
K. Parameswaran