A new government report on climate change shows that global emissions of greenhouse gases have increased to very high levels despite various policies to reduce climate change. Building energy accounts for 40% of the world’s energy consumption and accounts for 33% of the world’s greenhouse gas emissions. This study applied the LEAP (Long-range energy alternatives planning) model and Bass diffusion method for predicting the total energy consumption and GHG (Greenhouse Gas) emissions from the residential and commercial building sector of Sejong City in South Korea. Then, using the Bass diffusion model, three scenarios were analyzed (REST: Renewable energy supply target, BES: Building energy saving, BEP: Building energy policy) for GHG reduction. The GHG emissions for Sejong City for 2015–2030 were analyzed, and the past and future GHG emissions of the city were predicted in a Business-as-Usual (BAU) scenario. In the REST scenario, the GHG emissions would attain a 24.5% reduction and, in the BES scenario, the GHG emissions would attain 12.81% reduction by 2030. Finally, the BEP scenario shows the potential for a 19.81% GHG reduction. These results could be used to guide the planning and development of the new city.
25 June 2023 in Case Studies in Thermal Engineering
This study was conducted to propose an optimal methodology for deriving a standard model from existing residential buildings. To strategically improve existing residential buildings, it is necessary to identify standard models that can be used as quantitative standards. In this study, a total of six methods were established for different algorithms in the dimensionality reduction and clustering stage of the data preprocessing stage. In addition, a total of 22,342 households’ data were analyzed, and a total of 26 variables were used to perform cluster analysis. The process of method 6 (data pre-processing, principal components analysis, clustering [K-medoids], verification) was proposed as a way to derive the standard model from the existing Korean housing. The method proposed in this study is capable of deriving a number of standard models considering all variables (n) in a single analysis. The representative building derived in this study contains a lot of building data, so it can be effectively used for planning and research related to buildings on a regional and national scale. In addition, this process can be applied to various buildings to derive representative buildings.
The airtightness of a building has a significant impact on energy savings, structural longevity, and indoor air quality for occupants. Therefore, it is essential to accurately measure the airtightness of buildings, though the widely used fan pressurization method suffers from several shortcomings. For this reason, transient methods have recently emerged to assess airtightness by monitoring pressure changes over time, but studies using transient methods in this field are rare. In this study, we selected three representative buildings to conduct field tests to verify the practical applicability of the improved transient method. To verify the results of the transient method, we conducted a comparison experiment with the blower door test: a widely used measurement method. When measuring the effective leakage area, the average standard deviation of the transient method was 0.903 cm2, which was much smaller than the blower door test result of 1.488 cm2. In addition, the recorded standard errors ranged from 0.197 cm2 to 0.816 cm2 for the transient method and from 0.269 cm2 to 1.801 cm2 for the blower door test. Notably, the transitional method was more reproducible than the blower door test while showing similar accuracy. Given these results, it is expected that the improved transitional method can be used to evaluate airtightness performance in the field.
About Me
Working at Korea Institute of Eenergy Research since 2015
Working at Korea Institute of Eenergy Research since 2015