Yasunori Tada

Dr. Yasunori Tada


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2015 in Fibers
Verified
Journal Article
Open access
PDF file
YTYasunori Tada
Yasunori Tada
YAYusaku Amano
Yusaku Amano
TSTomonobu Sato
Tomonobu Sato
SSShigeru Saito
Shigeru Saito
MIMasahiro Inoue
Masahiro Inoue
The Holter monitor is used to measure an electrocardiogram (ECG) signal while a subject moves. However, the Holter monitor is uncomfortable for the subject. Another method of measuring the ECG signal uses a smart shirt. We developed a smart shirt that has six electrodes on the chest and can measure a detailed ECG, obtained with unipolar precordial leads. The electrodes and wires of the shirt are made of conductive ink that is flexible and stretchable. The smart shirt is stretchable and fits the body well. However, because of the gap between the smart shirt and the body, electrodes V1 and V2 do not touch the body consistently. We developed a conductive foam block that fills this gap. We investigated the characteristics of the conductive foam block, and measured ECG signals using the smart shirt. The electrical resistance of the conductive foam block was reduced by pressure. This characteristic could be utilized to measure the ECG signal because the block was pressed by the body and smart shirt. We could measure the ECG signal using the smart shirt and blocks while the subject walked and could detect peaks of the ECG signal while the subject jogged slowly.

1 January 2008 in Journal of The Japan Institute of Electronics Packaging
Verified
Journal Article
Open access
PDF file
MIMasahiro Inoue
Masahiro Inoue
YKYasushi Kawahito
Yasushi Kawahito
YTYasunori Tada
Yasunori Tada
THTakahiro Hondo
Takahiro Hondo
TKToshimi Kawasaki
Toshimi Kawasaki
HIHiroshi Ishiguro
Hiroshi Ishiguro
An electronic packaging technique using silicone-based conductive adhesives was applied to the fabrication of tactile sensor sheets using poly (vinylidene fluoride) (PVDF) films for artificial skin applications in robots and related equipment. Silicone-based conductive adhesives containing 85 wt % Ag particles were employed for wiring and interconnection. In addition, the sensor sheet was perfectly encapsulated by injection molding of the silicone rubber. Prototype tactile sensor sheets were connected to a self-organized network of distributed processors and shown to work successfully.

7 January 2014 in The Journal of the Textile Institute
Verified
Journal Article
Closed access
YTYasunori Tada
Yasunori Tada
MIMasahiro Inoue
Masahiro Inoue
TTTomohiro Tokumaru
Tomohiro Tokumaru

4 February 2014 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
MIMasahiro Inoue
Masahiro Inoue
YTYasunori Tada
Yasunori Tada
YIYosuke Itabashi
Yosuke Itabashi
TTTomohiro Tokumaru
Tomohiro Tokumaru

1 January 2017 in IEEJ Transactions on Sensors and Micromachines
Verified
Journal Article
Closed access
PDF file
YAYusaku Amano
Yusaku Amano
YTYasunori Tada
Yasunori Tada
TSTomonobu Sato
Tomonobu Sato
SSShigeru Saito
Shigeru Saito
MIMasahiro Inoue
Masahiro Inoue
Dry electrodes of a smart shirt for measuring biological signals were prepared by the additive printing method using a stretchable conductive paste with Ag fillers loading. Interfacial impedance between the electrode and skin depended on the contact pressure of electrode and the moisture of stratum corneum. When moisture of stratum corneum was more than 30%, ECG could be measured using the stretchable electrodes printed on a compression shirt. However, noise signal in the ECG signal increased when the moisture of stratum corneum was less than 30%. To solve this problem, we propose to use additional electrodes made of an electrically conductive kneaded rubber.

1 December 2008
Verified
Book Chapter
Open access
PDF file
YTYasunori Tada
Yasunori Tada
MIMasahiro Inoue
Masahiro Inoue
TKToshimi Kawasaki
Toshimi Kawasaki
YKYasushi Kawahito
Yasushi Kawahito
Hiroshi IshiguroHiroshi Ishiguro
Hiroshi Ishiguro
KSKatsuaki Suganum
Katsuaki Suganum