Ning Mu

Dr. Ning Mu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
YPYong Pan
Yong Pan
NMNing Mu
Ning Mu
BLBo Liu
Bo Liu
BCBingqing Cao
Bingqing Cao
Wen WangWen Wang
Wen Wang
LYLiu Yang
Liu Yang
A novel surface acoustic wave (SAW) sensor array based on wireless communication network is prepared. The array is composed of four SAW sensors, a wireless communication network module, and a global positioning system (GPS) module. The four SAW sensors of the array are coated with triethanolamine, polyepichlorohydrin, fluoroalcoholpolysiloxane, and L-glutamic acid hydrochloride to detect hydrogen sulfide (H2S), 2-chloroethyl ethyl sulfide (CEES), dimethylmethylphosphonate (DMMP), and ammonia (NH3) at film thicknesses of 50–100 nm. The wireless communication network module consists of an acquisition unit, a wireless control unit, and a microcontroller unit. By means of Zigbee and Lora technologies, the module receives and transmits the collected data to a PC work station in real-time; moreover, the module can control the sensor array’s working mode and monitor the working status. Simultaneously, the testing location is determined by the GPS module integrated into the SAW sensor array. H2S, CEES, DMMP, and NH3 are detected in 300 m at different concentrations. Given the practical future application in environment in the future, the low, safe concentrations of 1.08, 0.59, 0.10, and 5.02 ppm for H2S, CEES, DMMP, and NH3, respectively, are detected at the lowest concentration, and the sensitivities of different sensors of the sensor array are 32.4, 14.9, 78.1 and 22.6 Hz/ppm, respectively. With the obtained fingerprints and pattern recognition technology, the detected gases can be recognized.

23 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
YPYong Pan
Yong Pan
NMNing Mu
Ning Mu
SSShao Shengyu
Shao Shengyu
LYLiu Yang
Liu Yang
Wen WangWen Wang
Wen Wang
SHShitang He
Shitang He
Self-assembly and molecular imprinting technologies are very attractive technologies for the development of artificial recognition systems and provide chemical recognition based on need and not happenstance. In this paper, we employed a b-cyclodextrin derivative surface acoustic wave (SAW) chemical sensor for detecting the chemical warfare agents (CWAs) sarin (O-Isoprophyl methylphosphonofluoridate, GB). Using sarin acid (isoprophyl hydrogen methylphosphonate) as an imprinting template, mono[6-deoxy-6-[(mercaptodecamethylene)thio]]-β-cyclodextrin was prepared by self-assembled method on one of the SAW oscillators. After templates’ removal, a sensitive and selective molecular imprinting (MIP) monolayer for GB was prepared. Electrochemical impedance spectroscopy and atomic force microscope (AFM) were used to characterize this film. Comparing the detection results to GB by MIP film and non-MIP film, the molecularly imprinting effect was also proved. The resulting SAW sensor could detect sarin as low as 0.10 mg/m3 at room temperature and the frequency shift was about 300 Hz. The response frequency increased linearly with increasing sarin concentration in the range of 0.7 mg/m3~3.0 mg/m3. When sarin was detected under different temperatures, the SAW sensor exhibited outstanding sensitivity and reliability.

19 May 2014 in Sensors
Verified
Journal Article
Open access
PDF file
YPYong Pan
Yong Pan
LYLiu Yang
Liu Yang
NMNing Mu
Ning Mu
SSShao Shengyu
Shao Shengyu
Wen WangWen Wang
Wen Wang
SHShitang He
Shitang He
This paper presents a new effective approach for the sensitive film deposition of surface acoustic wave (SAW) chemical sensors for detecting organophosphorus compounds such as O-ethyl-S-2-diisopropylaminoethyl methylphosphonothiolate (VX) containing sulfur at extremely low concentrations. To improve the adsorptive efficiency, a two-step technology is proposed for the sensitive film preparation on the SAW delay line utilizing gold electrodes. First, mono[6-deoxy-6-[(mercaptodecamethylene)thio]]-β-cyclodextrin is chosen as the sensitive material for VX detection, and a ~2 nm-thick monolayer is formed on the SAW delay line by the binding of Au-S. This material is then analyzed by atomic force microscopy (AFM). Second, the VX molecule is used as the template for molecular imprinting. The template is then removed by washing the delay line with ethanol and distilled water, thereby producing the sensitive and selective material for VX detection. The performance of the developed SAW sensor is evaluated, and results show high sensitivity, low detection limit, and good linearity within the VX concentration of 0.15–5.8 mg/m3. The possible interactions between the film and VX are further discussed.