Chiung-Fang Huang

Chiung-Fang Huang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
PJPo-Kai Juan
Po-Kai Juan
Fang FanFang Fan
Fang Fan
Wei-Chun LinWei-Chun Lin
Wei-Chun Lin
PLPei-Bang Liao
Pei-Bang Liao
CHChiung-Fang Huang
Chiung-Fang Huang
CLChen-Han Lee
Chen-Han Lee
This study applied poly-ε-caprolactone (PCL), a biomedical ceramic powder as an additive (nano-hydroxyapatite (nHA) or β-tricalcium diphosphate (β-TCP)), and sodium chloride (NaCl) and ammonium bicarbonate ((NH4)HCO3) as porogens; these stuffs were used as scaffold materials. An improved solvent-casting/particulate-leaching method was utilized to fabricate 3D porous scaffolds. In this study we examined the physical properties (elastic modulus, porosity, and contact angle) and degradation properties (weight loss and pH value) of the 3D porous scaffolds. Both nHA and β-TCP improved the mechanical properties (elastic modulus) of the 3D porous scaffolds. The elastic modulus (0.15~1.865 GPa) of the various composite scaffolds matched that of human cancellous bone (0.1~4.5 GPa). Osteoblast-like (MG63) cells were cultured, a microculture tetrazolium test (MTT) was conducted and alkaline phosphatase (ALP) activity of the 3D porous scaffolds was determined. Experimental results indicated that both nHA and β-TCP powder improved the hydrophilic properties of the scaffolds. The degradation rate of the scaffolds was accelerated by adding nHA or β-TCP. The MTT and ALP activity tests indicated that the scaffolds with a high ratio of nHA or β-TCP had excellent properties of in vitro biocompatibility (cell attachment and proliferation).

30 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Wei-Chun LinWei-Chun Lin
Wei-Chun Lin
Fang FanFang Fan
Fang Fan
CHChiung-Fang Huang
Chiung-Fang Huang
Yung-Kang ShenYung-Kang Shen
Yung-Kang Shen
Hao WangHao Wang
Hao Wang
In this study, we determined the effects of design and processing parameters of precision injection molding (PIM) to minimize warpage phenomena of micro-sized parts using various plastics (polyoxymethylene (POM), acrylonitrile-butadiene-styrene (ABS), polypropylene (PP), polyamide (PA), and ABS+ polycarbonate (PC)). We applied a numerical simulation (Moldflow) to determine the runner’s balance in multi-cavities of the micro-sized part and simulate the warpage phenomenon of micro-parts with PIM. We used simulation data to fabricate a steel mold by computer numerical control (CNC) machining. In this, we study manufactured a micro-sized part and measured its warpage value using various PIM process parameters (melt temperature, mold temperature, injection pressure, and filling time). In order to obtain optimal results (i.e., minimum warpage), we employed the Taguchi method and grey theory to discern the influence of each process parameter on PIM. Finally, we determined that the most significant PIM process parameter influencing the warpage phenomenon of micro-sized parts was the mold temperature, regardless of whether in terms of the experimental results, numerical simulations, or grey theory. The PA material had the most suitable properties for application for micro-sized parts, regardless of whether in terms of experimental results, numerical simulations, or grey theory for PIM. This study also illustrates that micro-sized parts can be fabricated by PIM without the use of micro-injection molding, and we determined that the mold temperature required for molding does not need to be higher than the glass-transition temperature of the material.

31 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
PPPei-Wen Peng
Pei-Wen Peng
CHChiung-Fang Huang
Chiung-Fang Huang
HCHsu Ching-Ming
Hsu Ching-Ming
Ann (Yu-Ting) ChenAnn (Yu-Ting) Chen
Ann (Yu-Ting) Chen
HNHo-Him Ng
Ho-Him Ng
WLWei-Fang Lee
Wei-Fang Lee
This study evaluated color stability and staining susceptibility of five direct resin-based composites (RBCs) subjected to light-activated in-office bleaching with 40% hydrogen peroxide (HP). The test materials included 5 RBCs, which consisted of one nano-filled, one sub-micron, one bulk-filled, and two nano-hybrid RBC types. Ten disc-shaped specimens of each RBC were fabricated and divided into bleaching (BLE) and non-bleaching (CON) groups (n = 5 for each group). Specimens were then immersed in red wine solution over 4 h. A spectrophotometer was used to obtain Commission Internationale de l’Eclairage (CIE) L*a*b* parameters for each of the following periods tested: before bleaching (TBA), after bleaching (TBL), and after staining (TST). Color stability and staining susceptibility were evaluated using two metrics, CIEDE2000 color differences (ΔE00) and whiteness variations using the whiteness index (ΔWID). Data were analyzed using repeated measures two-way analysis of variance (ANOVA) (α = 0.05). Statistically significant and clinically unaccepted ΔE00 and ΔWID were observed for all tested specimens between TBA and TBL. The nano-hybrid type RBCs showed the highest discoloration among materials after bleaching treatment. The BLE group exhibited significantly higher ΔE00 and ΔWID than the CON group for all the tested RBCs between TBA and TST. The sub-micron type RBC showed the highest discoloration among materials after immersion in the red wine. Conclusion. The light-activated in-office bleaching with 40% HP’s influences on color and whiteness index were material-dependent. The use of bleaching treatment also increased the susceptibility to red wine for all RBCs.

8 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KOKeng-Liang Ou
Keng-Liang Ou
PHPing-Jen Hou
Ping-Jen Hou
BHBai-Hung Huang
Bai-Hung Huang
HCHsin-Hua Chou
Hsin-Hua Chou
TYTzu-Sen Yang
Tzu-Sen Yang
TUTakaaki Ueno
Takaaki Ueno
This study aimed to elucidate the local effect and micro-computed tomographic (μ-CT) assessment following bone implantation of an innovative bioceramic (α-calcium sulfate hemihydrate; α-CSH) on femur lateral condyle cortical bone of rabbit models. The innovative α-CSH bioceramic was synthesized through a green processing technology (microwave irradiation treatment). The bilateral implantation model was performed among 24 New Zealand White rabbits which were divided into three groups based on the type of filling materials: α-CSH, control, and blank. Treatments were performed in defects with 6 mm diameter and 7 mm depth and observed after 2, 4, 8, and 12 weeks. Material reaction and bone formation after implantation were evaluated radiographically and histopathologically. The μ-CT analysis results showed that the degradation of α-CSH and control material was similar at 4 and 8 weeks. The bone volume in the defects indicated the α-CSH increased most in 8 weeks. In histopathological evaluation, the α-CSH group was repaired with lamellar bone and well-grown bone marrow infiltration similar to the control material. Moreover, the α-CSH revealed a faster degradation rate and better healing progress than the control material under the same conditions. Therefore, the α-CSH was confirmed to be useful in promoting osteoconduction and in controlling the resorption rate in bone defects. Further, the innovative α-CSH could be considered as a promising bone substitute for utilization in bone reconstructive therapy in dental and orthopedic fields.

4 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
HHHuei-Yu Huang
Huei-Yu Huang
Fang FanFang Fan
Fang Fan
Wei-Chun LinWei-Chun Lin
Wei-Chun Lin
CHChiung-Fang Huang
Chiung-Fang Huang
Yung-Kang ShenYung-Kang Shen
Yung-Kang Shen
MRMuhammad Ruslin
Muhammad Ruslin
In this study, we designed and fabricated transmission parts for a flapping-wing micro-aerial vehicle (FW-MAV), which was fabricated by precision injection molding, and analyzed its warpage phenomena. First, a numerical simulation (Moldflow) was used to analyze the runner balance and temperature, pressure, and stress distributions of the base, gears, and linkage of the transmission structures in an FW-MAV. These data were then applied to fabricate a steel mold for an FW-MAV. Various process parameters (i.e., injection temperature, mold temperature, injection pressure, and packing time) for manufacturing transmission parts for the FW-MAV by precision injection molding were compared. The Taguchi method was employed to determine causes of warpage in the transmission parts. The experimental results revealed that the causes of warpage in the transmission parts were, in order of importance, the mold temperature, injection pressure, packing time, and injection temperature. After the transmission parts were assembled on the FW-MAV, experiments revealed that the MAV could achieve a flight time of 180 s. Mass production of the FW-MAV by precision injection molding could potentially produce substantial savings in time, manpower, and cost.

29 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Wei-Chun LinWei-Chun Lin
Wei-Chun Lin
Fang FanFang Fan
Fang Fan
CHChiung-Fang Huang
Chiung-Fang Huang
Yung-Kang ShenYung-Kang Shen
Yung-Kang Shen
LWLiping Wang
Liping Wang
When the size of a liquid crystal display (LCD) increases, the light guiding plate (LGP) as the main part of the LCD must adopt a wedge-shaped plate to reduce its weight (the thickness of the LGP decreases because of this) and guide the light to the LCD screen. Micro-injection molding (MIM) is commonly used to manufacture LGPs. During the filling phase of MIM, the entire entering polymer melt front of the LGP should reach the end of the mold cavity at the same time. In this way, there will be no shrinkage or warpage of the LGP in its subsequent application, but it is difficult for the wedge-shaped LGP to meet these requirements. Therefore, the authors hoped to investigate MIM process parameters to change this situation. Otherwise, the LGP is easily deformed during the manufacturing process. Flow characteristics of LGPs were investigated during the filling phase of MIM in this study. Experimental and 3D numerical simulations were used to analyze the hysteresis, i.e., the advance of the polymer melt front of the LGP in MIM. Study results showed that a low injection speed caused a hysteresis effect of the plastic melt front, the solution was to increase the injection speed to improve the situation and an injection speed of 10 cm/s could achieve uniformity of the melt front in MIM. The research results showed that the filling situation of the LGP of MIM in the experiment was very close to that of the 3D numerical simulation.