This study applied poly-ε-caprolactone (PCL), a biomedical ceramic powder as an additive (nano-hydroxyapatite (nHA) or β-tricalcium diphosphate (β-TCP)), and sodium chloride (NaCl) and ammonium bicarbonate ((NH4)HCO3) as porogens; these stuffs were used as scaffold materials. An improved solvent-casting/particulate-leaching method was utilized to fabricate 3D porous scaffolds. In this study we examined the physical properties (elastic modulus, porosity, and contact angle) and degradation properties (weight loss and pH value) of the 3D porous scaffolds. Both nHA and β-TCP improved the mechanical properties (elastic modulus) of the 3D porous scaffolds. The elastic modulus (0.15~1.865 GPa) of the various composite scaffolds matched that of human cancellous bone (0.1~4.5 GPa). Osteoblast-like (MG63) cells were cultured, a microculture tetrazolium test (MTT) was conducted and alkaline phosphatase (ALP) activity of the 3D porous scaffolds was determined. Experimental results indicated that both nHA and β-TCP powder improved the hydrophilic properties of the scaffolds. The degradation rate of the scaffolds was accelerated by adding nHA or β-TCP. The MTT and ALP activity tests indicated that the scaffolds with a high ratio of nHA or β-TCP had excellent properties of in vitro biocompatibility (cell attachment and proliferation).
Current 3D-printing technology has been widely used for creating dental resin restorations. This study aimed to evaluate the effect of light intensity, time, and energy post-curing on the surface color of 3D-printed resin crowns. However, the influences of post-curing parameters on the restoration after printing still need to be explored. Therefore, this project investigates the effect of post-cure conditions on resin color. Specimens from single-crown (SC) and pontic (PO) specimens underwent post-curing at various light intensities (105, 210, 420, 630, and 860 mW/cm2) for 5, 10, and 15 min. Specimens were observed at three predetermined points and measured using a commercial spectrophotometer that utilizes the CIE Lab∗ color space. Subsequently, samples were analyzed for color differences (ΔE). ΔE color differences in evaluated samples were influenced by the light intensity, time, and energy post-curing. SC samples showed a significant color difference (P < 0.05), with the lowest value at 5 min of 16 (860 mW/cm2), while 10 and 15 min had a difference of 4 (210 mW/cm2). PO samples exhibited a significant decrease in the color difference (P < 0.05) at 5 and 10 min of 16 (860 mW/cm2), and at 15 min of 12 (630 mW/cm2). The results of this study indicate that exposing a resin crown to a high light intensity results in color stability and allows shorter post-curing times.
Hydroxyapatite has excellent biocompatibility and osteo-conductivity and, as the main inorganic component of human bones and teeth, is commonly used for bone repair. Its original characteristics can be changed by metal ion substitution. Cobalt ions can act as hypoxia-inducible factors and accelerate bone repair. At the same time, cobalt has paramagnetic properties and is often used in the study of medical imaging and target drugs. Through the introduction of cobalt ions, the unique hydroxyapatite has better biological activity and positioning of medical images. Herein, cobalt-substituted hydroxyapatite (CoHA) was synthesized on the surface of a titanium plate by electrochemical deposition and changes in the power output mode to explore the impact on CoHA. Electrochemical deposition with a pulse current significantly improved the productivity and uniformity of CoHA on the surface of titanium. CoHA show paramagnetic characteristics by a superconducting quantum interference device (SQUID). Resulting smaller particle size and circular morphology improves the magnetic strength of CoHA. Magnetic resonance imaging (MRI) of CoHA showed significant image contrast effect at low concentrations. The calculated particle relaxation rate was higher than other common MRI contrast agents. Biocompatibility of CoHA powder was evaluated using the human osteosarcoma cell line (MG63) which confirmed that CoHA is not cytotoxic and can promote cell growth and extracellular matrix mineralization. With the release of cobalt ions, CoHA was found to be significantly good in repression E. coli indicating about than 95% reduction in bacterial growth. The as-synthesized CoHA has a low degree of crystallinity, highly sensitive image contrast effect, and good bioactivity, and may have potential applications in bone repair and MRI.
In this study, we determined the effects of design and processing parameters of precision injection molding (PIM) to minimize warpage phenomena of micro-sized parts using various plastics (polyoxymethylene (POM), acrylonitrile-butadiene-styrene (ABS), polypropylene (PP), polyamide (PA), and ABS+ polycarbonate (PC)). We applied a numerical simulation (Moldflow) to determine the runner’s balance in multi-cavities of the micro-sized part and simulate the warpage phenomenon of micro-parts with PIM. We used simulation data to fabricate a steel mold by computer numerical control (CNC) machining. In this, we study manufactured a micro-sized part and measured its warpage value using various PIM process parameters (melt temperature, mold temperature, injection pressure, and filling time). In order to obtain optimal results (i.e., minimum warpage), we employed the Taguchi method and grey theory to discern the influence of each process parameter on PIM. Finally, we determined that the most significant PIM process parameter influencing the warpage phenomenon of micro-sized parts was the mold temperature, regardless of whether in terms of the experimental results, numerical simulations, or grey theory. The PA material had the most suitable properties for application for micro-sized parts, regardless of whether in terms of experimental results, numerical simulations, or grey theory for PIM. This study also illustrates that micro-sized parts can be fabricated by PIM without the use of micro-injection molding, and we determined that the mold temperature required for molding does not need to be higher than the glass-transition temperature of the material.