Phuong Thao Mai

Mrs. Phuong Thao Mai

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
TBTherese Bormann
Therese Bormann
PMPhuong Thao Mai
Phuong Thao Mai
JGJens Gibmeier
Jens Gibmeier
RSRobert Sonntag
Robert Sonntag
UMUlrike Müller
Ulrike Müller
JKJ. Philippe Kretzer
J. Philippe Kretzer
Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments.

10 April 2022 in Acta Biomaterialia
Verified
Journal Article
Closed access
TBTherese Bormann
Therese Bormann
LNLaura Nebel
Laura Nebel
UMUlrike Müller
Ulrike Müller
PMPhuong Thao Mai
Phuong Thao Mai
JGJens Gibmeier
Jens Gibmeier
JKJ. Philippe Kretzer
J. Philippe Kretzer

4 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
PMPhuong Thao Mai
Phuong Thao Mai
TBTherese Bormann
Therese Bormann
UMUlrike Müller
Ulrike Müller
JKJ. Philippe Kretzer
J. Philippe Kretzer
JGJens Gibmeier
Jens Gibmeier

26 February 2023 in Metals
Verified
Journal Article
Open access
PDF file
AOAnna-Lena Otte
Anna-Lena Otte
PMPhuong Thao Mai
Phuong Thao Mai
ASAndreas Stark
Andreas Stark
MHMarkus Hoelzel
Markus Hoelzel
MHMichael Hofmann
Michael Hofmann
JGJens Gibmeier
Jens Gibmeier
The aerospace alloy Ti-6246 was subjected to inductive heat treatments with high heating and quenching rates (up to 1500 K/s) while being applied to an in situ diffraction study at the HEMS beamline P07B at DESY. Thereby, the characterization of the emerging phases was possible at any point in the process. The heat treatment schedules include the preparation of Ti-6246 samples by means of a homogenization treatment and subsequent quenching to trigger α″-martensite formation. In order to simulate fast reheating within the scope of application, the samples were reheated to the upper range of possible service temperatures (550–650 °C) with a heating rate of 100 K/s. In a second heat treatment design, the homogenized and quenched sample state was exposed to high-temperature tempering at 840 °C, which aims for the elimination of α″. Again, fast reheating to the same service temperatures was executed. With the aim of this approach, the stability of the microstructure consisting of α-Ti, β-Ti and α″-martensite was characterized. Further, the martensite decomposition path was analyzed. It shows a two-tier nature, firstly approaching the bcc β-unit cell in the low-temperature range (<400 °C) but subsequently transforming into an hcp-like unit cell and later on into equilibrium α-Ti.

5 April 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
TBTherese Bormann
Therese Bormann
UMUlrike Müller
Ulrike Müller
JGJens Gibmeier
Jens Gibmeier
PMPhuong Thao Mai
Phuong Thao Mai
TRTobias Renkawitz
Tobias Renkawitz
JKJ. Philippe Kretzer
J. Philippe Kretzer
Background: Wear and corrosion at modular neck tapers in THA can lead to major clinical implications such as periprosthetic osteolysis, adverse local tissue reactions, or implant failure. The material degradation processes at the taper interface are complex and involve fretting corrosion, third-body abrasion, as well as electrochemical and crevice corrosion. One phenomenon in this context is imprinting of the head taper, where the initially smooth surface develops a topography that reflects the rougher neck taper profile. The formation mechanism of this specific phenomenon, and its relation to other observed damage features, is unclear. An analysis of retrieved implants may offer some insights into this process. Questions/purposes: (1) Is imprinting related to time in situ of the implants and to the taper damage modes of corrosion and fretting? (2) Are implant design parameters like neck taper profile, stem material, or head seating associated with the formation of imprinting? (3) Is imprinting created by an impression of the neck taper profile or can a different mechanistic explanation for imprinting be derived? Methods: Thirty-one THAs with cobalt-chromium-molybdenum-alloy (CoCrMo) heads retrieved between 2013 and 2019 at revision surgery from an institutional registry were investigated. Inclusion criteria were: 12/14 tapers, a head size of 36 mm or smaller, time in situ more than 1 year, and intact nonmodular stems without sleeve adaptors. After grouping the residual THAs according to stem type, stem material, and manufacturer, all groups of three or more were included. Of the resulting subset of 31 retrievals, nine THAs exhibited a still assembled head-neck taper connection. The median (range) time in situ was 5 years (1 to 23). Two stem materials (21 titanium-alloy and 10 stainless steel), three kinds of bearing couples (11 metal-on-metal, 13 metal-on-polyethylene, and seven dual-mobility heads), and two different neck taper profiles (six wavy profile and 25 fluted profile) were present in the collection. Four THAs exhibited signs of eccentric head seating. The 31 investigated THAs represented 21% of the retrieved THAs with a CoCrMo alloy head during the specified period. At the head tapers, the damage modes of corrosion, fretting, and imprinting were semiquantitatively rated on a scale between 0 (no corrosion/fretting/imprinting) and 3 (severe corrosion/fretting/imprinting). Corrosion and fretting were assessed applying the Goldberg score, with the modification that the scale started at 0 and not at 1. Imprinting was assessed with a custom scoring system. Rating was done individually at the proximal and distal head taper half and summed to one total damage score for each retrieval and damage mode. Correlations between the damage modes and time in situ and between the damage modes among each other, were assessed using the Spearman rank order correlation coefficient (ρ). Associations between imprinting and implant design parameters were investigated by comparing the total imprinting score distributions with the Mann-Whitney U-test. Metallographically prepared cross-sections of assembled head-neck taper connections were examined by optical microscopy and disassembled head and neck taper surfaces were assessed by scanning electron microscopy (SEM). Results: The imprinting damage score increased with time in-situ (ρ = 0.72; p < 0.001) and the corrosion damage score (ρ = 0.63; p < 0.001) but not with the fretting damage score (ρ = 0.35; p = 0.05). There was no difference in total imprinting score comparing neck taper profiles or stem materials, with the numbers available. Eccentric head seating had elevated total imprinting score (median 6 [interquartile range 0]) compared with centric seating (median 1 [2]; p = 0.001). Light optical investigations showed that imprinting can be present on the head taper surfaces even if the depth of abraded material exceeds the neck taper profile height. SEM investigations showed bands of pitting corrosion in the imprinted grooves. Conclusion: The microscopic investigations suggest that imprinting is not an independent phenomenon but a process that accompanies the continuous material degradation of the head taper surface because of circular damage on the passive layer induced by grooved neck tapers. Clinical Relevance: Material loss from head-neck taper connections involving CoCrMo alloy heads is a source of metal ions and could potentially be reduced if hip stems with smooth neck tapers were used. Surgeons should pay attention to the exact centric seating of the femoral head onto the stem taper during joining of the parts.

6 October 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SSStefan Schroeder
Stefan Schroeder
JGJens Gibmeier
Jens Gibmeier
PMPhuong Thao Mai
Phuong Thao Mai
MFMaximilian C. M. Fischer
Maximilian C. M. Fischer
MIMoritz M Innmann
Moritz M Innmann
JKJ. Philippe Kretzer
J. Philippe Kretzer
Due to the lower fatigue resistance of LPBF manufactured Ti6Al4V alloy compared to wrought material, hip stems are still manufactured conventionally, despite the advantages of patient-specific joint replacements. Therefore, the aim of the study was the investigation of appropriate post-treatments to increase the fatigue resistance of LPBF manufactured Ti6Al4V alloy using a four-point bending setup and a Locati-test. The results showed that only a combination of a hot isostatic pressing process and a sufficient surface treatment can lead to similar fatigue results as wrought material. Thereby, machining, deep rolling and shot peening turned out to be suitable surface treatments. For complex geometries like hip stems, shot peening is the most sufficient surface treatment. A combined surface treatment of shot peening and polishing led to similar fatigue results as the shot peening process alone. It can be followed that a combination of shot peening with a previous hot isostatic pressing process leads to satisfying fatigue results comparable to the wrought material and can be applied on complex geometries like hip stems. In addition, shoulder and neck area of a hip stem can be polished after the HIP process and the shot peening procedure without any reduction in fatigue strength.