Robert Sonntag

Mr. Robert Sonntag

Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Acta Biomaterialia
Verified
Journal Article
Closed access
RSRobert Sonntag
Robert Sonntag
JRJ. Reinders
J. Reinders
JKJ.P. Kretzer
J.P. Kretzer

7 August 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RSRobert Sonntag
Robert Sonntag
JRJörn Reinders
Jörn Reinders
JRJohannes S. Rieger
Johannes S. Rieger
DHDaniel Walter Werner Heitzmann
Daniel Walter Werner Heitzmann
JKJ. Philippe Kretzer
J. Philippe Kretzer
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.

1 January 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SSStefan Schroeder
Stefan Schroeder
SBSteffen Braun
Steffen Braun
UMUlrike Mueller
Ulrike Mueller
MVMatthias Vogel
Matthias Vogel
RSRobert Sonntag
Robert Sonntag
JKJ. Philippe Kretzer
J. Philippe Kretzer

1 January 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
SBSteffen Braun
Steffen Braun
RSRobert Sonntag
Robert Sonntag
SSStefan Schroeder
Stefan Schroeder
UMUlrike Mueller
Ulrike Mueller
SJSebastian Jaeger
Sebastian Jaeger
JKJ. Philippe Kretzer
J. Philippe Kretzer

25 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
TBTherese Bormann
Therese Bormann
PMPhuong Thao Mai
Phuong Thao Mai
JGJens Gibmeier
Jens Gibmeier
RSRobert Sonntag
Robert Sonntag
UMUlrike Müller
Ulrike Müller
JKJ. Philippe Kretzer
J. Philippe Kretzer
Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments.

8 September 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RSRobert Sonntag
Robert Sonntag
SBSteffen Braun
Steffen Braun
LALoay Al-Salehi
Loay Al-Salehi
JRJoern Reinders
Joern Reinders
UMUlrike Mueller
Ulrike Mueller
JKJ. Philippe Kretzer
J. Philippe Kretzer
Wear of total hip replacements has been the focus of many studies. However, frictional effects, such as high loading on intramodular connections or the interface to the bone, as well as friction associated squeaking have recently increased interest about the amount of friction that is generated during daily activities. The aim of this study was thus to establish and validate a three-dimensional friction setup under standardized conditions. A standard hip simulator was modified to allow for high precision measurements of small frictional effects in the hip during three-dimensional hip articulation. The setup was verified by an ideal hydrostatic bearing and validated with a static-load physical pendulum and an extension-flexion rotation with a dynamic load profile. Additionally, a pendulum model was proposed for screening measurement of frictional effects based on the damping behavior of the angular oscillation without the need for any force/moment transducer. Finally, three-dimensional friction measurements have been realized for ceramic-on-polyethylene bearings of three different sizes (28, 36 and 40 mm). A precision of less than 0.2 Nm during three-dimensional friction measurements was reported, while increased frictional torque (resultant as well as taper torque) was measured for larger head diameters. These effects have been confirmed by simple pendulum tests and the theoretical model. A comparison with current literature about friction measurements is presented. This investigation of friction is able to provide more information about a field that has been dominated by the reduction of wear. It should be considered in future pre-clinical testing protocols given by international organizations of standardization.