Robert Sonntag

Mr. Robert Sonntag

Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Acta Biomaterialia
Verified
Journal Article
Closed access
RSRobert Sonntag
Robert Sonntag
JRJ. Reinders
J. Reinders
JKJ.P. Kretzer
J.P. Kretzer

7 August 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RSRobert Sonntag
Robert Sonntag
JRJörn Reinders
Jörn Reinders
JRJohannes S. Rieger
Johannes S. Rieger
DHDaniel Walter Werner Heitzmann
Daniel Walter Werner Heitzmann
JKJ. Philippe Kretzer
J. Philippe Kretzer
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.

1 January 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SSStefan Schroeder
Stefan Schroeder
SBSteffen Braun
Steffen Braun
UMUlrike Mueller
Ulrike Mueller
MVMatthias Vogel
Matthias Vogel
RSRobert Sonntag
Robert Sonntag
JKJ. Philippe Kretzer
J. Philippe Kretzer

1 January 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
SBSteffen Braun
Steffen Braun
RSRobert Sonntag
Robert Sonntag
SSStefan Schroeder
Stefan Schroeder
UMUlrike Mueller
Ulrike Mueller
SJSebastian Jaeger
Sebastian Jaeger
JKJ. Philippe Kretzer
J. Philippe Kretzer

25 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
TBTherese Bormann
Therese Bormann
PMPhuong Thao Mai
Phuong Thao Mai
JGJens Gibmeier
Jens Gibmeier
RSRobert Sonntag
Robert Sonntag
UMUlrike Müller
Ulrike Müller
JKJ. Philippe Kretzer
J. Philippe Kretzer
Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments.

15 May 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
RSRobert Sonntag
Robert Sonntag
JGJens Gibmeier
Jens Gibmeier
SPSamuel Pulvermacher
Samuel Pulvermacher
UMUlrike Mueller
Ulrike Mueller
JEJohannes Eckert
Johannes Eckert
JKJ. Philippe Kretzer
J. Philippe Kretzer
Background: The risk of femoral stem fracture after total hip replacement is low and can often be associated with a specific implant system or other factors that may reduce the fatigue strength. Additionally, damage to a metal component during revision surgery by an electrocautery device may further affect the fatigue behavior. Methods: Two clinical cases of stem failure after revision of fractured ceramic components are presented; the retrieved components were analyzed for the cause of failure. In vitro cyclic load-to-failure testing of titanium alloy femoral stems after electrocautery application at 2 different locations (at the base and about midway on the femoral neck) was performed using a stepwise increase in load until implant fracture occurred. In addition, a detailed characterization of the local material structure around the electrocautery marks was performed. Results: Superficial discoloration and melting marks were found on the retrieved components, including at the location of crack initiation in the anterolateral region, which may have reduced the fatigue strength of the material. In addition, elemental analysis indicated material transfer from the electrocautery tip. Damage to the surface by the electrocautery device significantly reduced the in vitro load to failure by up to 47% compared with that of undamaged femoral neck specimens. Material analysis revealed a relevant modification in microstructure, with an extension of approximately 2.7 mm and a depth of 550 µm, which could be divided in 3 structural zones. Conclusions: Intraoperative electrocautery device contact with the implant during surgical revision of a total hip replacement cannot always be avoided. However, on the basis of our findings, the risk of implant failure is increased due to a change in microstructure and a potential reduction of the implant’s fatigue strength. Surgeons and manufacturers of electrocautery devices should be aware of this concern. Clinical Relevance: During revision surgery, contact between an electrocautery device and the femoral component should be avoided to reduce the chance of subsequent femoral neck fracture.