Saghi Forouhi

Dr. Saghi Forouhi

Department of Electrical Engineering (ISY), Linköping University, Linköping, Östergötland, Sweden
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
APAbbas Panahi
Abbas Panahi
DSDeniz Sadighbayan
Deniz Sadighbayan
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
Field-effect transistor (FET) biosensors have been intensively researched toward label-free biomolecule sensing for different disease screening applications. High sensitivity, incredible miniaturization capability, promising extremely low minimum limit of detection (LoD) at the molecular level, integration with complementary metal oxide semiconductor (CMOS) technology and last but not least label-free operation were amongst the predominant motives for highlighting these sensors in the biosensor community. Although there are various diseases targeted by FET sensors for detection, infectious diseases are still the most demanding sector that needs higher precision in detection and integration for the realization of the diagnosis at the point of care (PoC). The COVID-19 pandemic, nevertheless, was an example of the escalated situation in terms of worldwide desperate need for fast, specific and reliable home test PoC devices for the timely screening of huge numbers of people to restrict the disease from further spread. This need spawned a wave of innovative approaches for early detection of COVID-19 antibodies in human swab or blood amongst which the FET biosensing gained much more attention due to their extraordinary LoD down to femtomolar (fM) with the comparatively faster response time. As the FET sensors are promising novel PoC devices with application in early diagnosis of various diseases and especially infectious diseases, in this research, we have reviewed the recent progress on developing FET sensors for infectious diseases diagnosis accompanied with a thorough discussion on the structure of Chem/BioFET sensors and the readout circuitry for output signal processing. This approach would help engineers and biologists to gain enough knowledge to initiate their design for accelerated innovations in response to the need for more efficient management of infectious diseases like COVID-19.

1 October 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
RDRasoul Dehghani
Rasoul Dehghani
EGEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh

13 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
Emerging infectious diseases such as coronavirus disease of 2019 (COVID-19), Ebola, influenza A, severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS) in recent years have threatened the health and security of the global community as one of the greatest factors of mortality in the world. Accurate and immediate diagnosis of infectious agents and symptoms is a key to control the outbreak of these diseases. Rapid advances in complementary metal-oxide-semiconductor (CMOS) technology offers great advantages like high accuracy, high throughput and rapid measurements in biomedical research and disease diagnosis. These features as well as low cost, low power and scalability of CMOS technology can pave the way for the development of powerful devices such as point-of-care (PoC) systems, lab-on-chip (LoC) platforms and symptom screening devices for accurate and timely diagnosis of infectious diseases. This paper is an overview of different CMOS-based devices such as optical, electrochemical, magnetic and mechanical sensors developed by researchers to mitigate the problems associated with these diseases.

24 September 2021 in Actuators
Verified
Journal Article
Open access
PDF file
AMAamir Minhas-Khan
Aamir Minhas-Khan
MGMorteza Ghafar-Zadeh
Morteza Ghafar-Zadeh
TSTina Shaffaf
Tina Shaffaf
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
ASAnthony Scime
Anthony Scime
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
Informational Deoxyribonucleic Acid (iDNA) has gained the attention of many researchers and pioneer companies for the development of novel storage systems for the long-term and high-density storing of information. This research focuses on the physical storage of iDNA strands to address some of the current challenges by evaluating the accuracy of the process of iDNA retrieval from the surface after the dehydration process. For this aim, a UV-Vis spectrophotometric technique was used to measure the concentration of the DNA samples. Although spectroscopy has been widely employed for the evaluation of DNA concentration and contamination in a solution, it has not been used to investigate dry-state DNA, which is one of the preferred storage formats for the long-term retention of information. These results demonstrate that the UV-Vis spectrophotometric technique can be used to accurately measure dry-state DNA before the retrieval and its residues after the DNA retrieval process. This paper further examines the storage/retrieval process by investigating the relationship between the storage time and the amount of retrieved DNA or the DNA residue left on various surfaces. Based on the experimental results demonstrated and discussed in this paper, UV-Vis spectrophotometry can be used for monitoring dry-state DNA with a high accuracy larger than 98%. Moreover, these results reveal that the hydrophilicity and hydrophobicity of the surface do not significantly affect DNA retrieval over a one-month time period.

9 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
RDRasoul Dehghani
Rasoul Dehghani
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
This paper proposes a novel charge-based Complementary Metal Oxide Semiconductor (CMOS) capacitive sensor for life science applications. Charge-based capacitance measurement (CBCM) has significantly attracted the attention of researchers for the design and implementation of high-precision CMOS capacitive biosensors. A conventional core-CBCM capacitive sensor consists of a capacitance-to-voltage converter (CVC), followed by a voltage-to-digital converter. In spite of their high accuracy and low complexity, their input dynamic range (IDR) limits the advantages of core-CBCM capacitive sensors for most biological applications, including cellular monitoring. In this paper, after a brief review of core-CBCM capacitive sensors, we address this challenge by proposing a new current-mode core-CBCM design. In this design, we combine CBCM and current-controlled oscillator (CCO) structures to improve the IDR of the capacitive readout circuit. Using a 0.18 μm CMOS process, we demonstrate and discuss the Cadence simulation results to demonstrate the high performance of the proposed circuitry. Based on these results, the proposed circuit offers an IDR ranging from 873 aF to 70 fF with a resolution of about 10 aF. This CMOS capacitive sensor with such a wide IDR can be employed for monitoring cellular and molecular activities that are suitable for biological research and clinical purposes.

29 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HTHamed Osouli tabrizi
Hamed Osouli tabrizi
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
OFOmid Farhanieh
Omid Farhanieh
ABAyhan Bozkurt
Ayhan Bozkurt
SMSebastian Magierowski
Sebastian Magierowski
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
CMOS capacitive sensors reported for high accuracy cellular molecular measurements typically suffer from significant parasitic capacitance changes caused by remnants and sediments during the experiment with several biological and chemical reactions. In this paper, we propose a novel calibration-free capacitive sensing system that addresses this problem. The proposed CMOS capacitive sensor includes interdigitated electrodes (IDEs), a capacitance-to-current converter with a wide input dynamic range (IDR), a variable reference capacitor, and an oscillator-based analog-to-digital converter (ADC) which has been fabricated using 0.35 μm AMS CMOS process. Sweeping the value of the variable reference capacitor from 0.1 fF up to 1.27 pF with a step of 10 fF and repeating the sweep each second during the experiment allows the creation of time-resolved three-dimensional (3D) fingerprints for the measurement of capacitance variations of the sample-electrode interface resulted from both the target material as well as non-target parasitic capacitances. We have tested the sensor using three different chemical solvents. The four different categories of curves that constitute the fingerprints of the chemicals showed a match with the post-layout simulation results. Capacitance change in the range of 0.416 fF up to 1.27 pF can practically be monitored. The electrode area of 110 μm by 220 μm and the micrometer chamber size allows for placing tiny droplets of a few microliters. The generated fingerprint is valid for the chemicals with a conductivity of up to 5 mS/cm.