Sebastian Magierowski

Dr. Sebastian Magierowski

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2018 in Bioengineering
Verified
Journal Article
Open access
PDF file
FAFirouz Abbasian
Firouz Abbasian
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
SMSebastian Magierowski
Sebastian Magierowski
Microorganisms have a significant influence on human activities and health, and consequently, there is high demand to develop automated, sensitive, and rapid methods for their detection. These methods might be applicable for clinical, industrial, and environmental applications. Although different techniques have been suggested and employed for the detection of microorganisms, and the majority of these methods are not cost effective and suffer from low sensitivity and low specificity, especially in mixed samples. This paper presents a comprehensive review of microbiological techniques and associated challenges for bioengineering researchers with an engineering background. Also, this paper reports on recent technological advances and their future prospects for a variety of microbiological applications.

6 August 2016 in Biosensors
Verified
Journal Article
Open access
PDF file
SMSebastian Magierowski
Sebastian Magierowski
YHYiyun Huang
Yiyun Huang
CWChengjie Wang
Chengjie Wang
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
DNA sequencers based on nanopore sensors present an opportunity for a significant break from the template-based incumbents of the last forty years. Key advantages ushered by nanopore technology include a simplified chemistry and the ability to interface to CMOS technology. The latter opportunity offers substantial promise for improvement in sequencing speed, size and cost. This paper reviews existing and emerging means of interfacing nanopores to CMOS technology with an emphasis on massively-arrayed structures. It presents this in the context of incumbent DNA sequencing techniques, reviews and quantifies nanopore characteristics and models and presents CMOS circuit methods for the amplification of low-current nanopore signals in such interfaces.

29 October 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
TMTania Moeinfard
Tania Moeinfard
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
SMSebastian Magierowski
Sebastian Magierowski
This review provides a comprehensive overview of point-of-care (PoC) devices across several key diagnostic applications, including blood analysis, infectious disease detection, neural interfaces, and commercialized integrated circuits (ICs). In the blood analysis section, the focus is on biomarkers such as glucose, dopamine, and aptamers, and their respective detection techniques. The infectious disease section explores PoC technologies for detecting pathogens, RNA, and DNA, highlighting innovations in molecular diagnostics. The neural interface section reviews advancements in neural recording and stimulation for therapeutic applications. Finally, a survey of commercialized ICs from companies such as Abbott and Medtronic is presented, showcasing existing PoC devices already in widespread clinical use. This review emphasizes the role of complementary metal-oxide-semiconductor (CMOS) technology in enabling compact, efficient diagnostic systems and offers insights into the current and future landscape of PoC devices.

18 November 2021 in IEEE Access
Verified
Journal Article
Open access
YDYunus Dawji
Yunus Dawji
MHMehdi Habibi
Mehdi Habibi
EGEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
SMSebastian Magierowski
Sebastian Magierowski
This paper introduces a high-speed mixed-signal readout array in 130-nm CMOS for the amplification and digitization of picoampere-range signals. Its design is inspired by the needs of emerging DNA sequencing technologies based on biological nanopore sensors. To overcome switching and substrate noise this system adopts an in-pixel analog-to-digital converter (ADC) architecture and a novel readout technique while consuming 10x less power than similar designs described in the literature. The in-pixel ADC architecture is inherently scalable and immune to electrical interference which can be extended to 100s of channels. With a 5 pF input capacitance, the amplifiers achieve a maximum bandwidth of 100 kHz and demonstrate a noise floor as low as 4 fA/ $\sqrt {\text{Hz}}$ and a gain in the range of $\text{G}\Omega $ at 10 kHz. Circuit noise behaviour and theoretical maximum performance estimates using behavioural models are also discussed.

24 September 2021 in Actuators
Verified
Journal Article
Open access
PDF file
AMAamir Minhas-Khan
Aamir Minhas-Khan
MGMorteza Ghafar-Zadeh
Morteza Ghafar-Zadeh
TSTina Shaffaf
Tina Shaffaf
Saghi ForouhiSaghi Forouhi
Saghi Forouhi
ASAnthony Scime
Anthony Scime
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
Informational Deoxyribonucleic Acid (iDNA) has gained the attention of many researchers and pioneer companies for the development of novel storage systems for the long-term and high-density storing of information. This research focuses on the physical storage of iDNA strands to address some of the current challenges by evaluating the accuracy of the process of iDNA retrieval from the surface after the dehydration process. For this aim, a UV-Vis spectrophotometric technique was used to measure the concentration of the DNA samples. Although spectroscopy has been widely employed for the evaluation of DNA concentration and contamination in a solution, it has not been used to investigate dry-state DNA, which is one of the preferred storage formats for the long-term retention of information. These results demonstrate that the UV-Vis spectrophotometric technique can be used to accurately measure dry-state DNA before the retrieval and its residues after the DNA retrieval process. This paper further examines the storage/retrieval process by investigating the relationship between the storage time and the amount of retrieved DNA or the DNA residue left on various surfaces. Based on the experimental results demonstrated and discussed in this paper, UV-Vis spectrophotometry can be used for monitoring dry-state DNA with a high accuracy larger than 98%. Moreover, these results reveal that the hydrophilicity and hydrophobicity of the surface do not significantly affect DNA retrieval over a one-month time period.

23 April 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HTHamed Osouli tabrizi
Hamed Osouli tabrizi
OFOmid Farhanieh
Omid Farhanieh
QOQiao Owen
Qiao Owen
SMSebastian Magierowski
Sebastian Magierowski
Ebrahim Ghafar-ZadehEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
This paper presents a new fully integrated CMOS capacitance sensor chip with a wider input dynamic range (IDR) compared to the state-of-the-art, suitable for a variety of life science applications. With the novel differential capacitance to current conversion topology, it achieves an IDR of about seven times higher compared to the previous charge based capacitive measurement (CBCM) circuits and about three times higher compared to the CBCM with cascode current mirrors. It also features a calibration circuitry consisting of an array of switched capacitors, interdigitated electrodes (IDEs) realized on the topmost metal layer, a current-controlled 300 MHz oscillator, and a counter-serializer to create digital output. The proposed sensor, fabricated in AMS 0.35 μm CMOS technology, enables a high-resolution measurement, equal to 416 aF, of physiochemical changes in the IDE with up to 1.27 pF input offset adjustment range (IOAR). With a measurement speed of 15 μs, this sensor is among the fast CMOS capacitive sensors in the literature. In this paper, we demonstrate its functionality and applicability and present the experimental results for monitoring 2 μL evaporating droplets of chemical solvents. By using samples of solvents with different conductivity and relative permittivity, a wide range of capacitance and resistance variations in the sample-IDE interface electric equivalent model can be created. In addition, the evaporating droplet test has inherently fast dynamic changes. Based on the results, our proposed device addresses the challenge of detecting small capacitance changes despite large parasitic elements caused by the ions in the solution or by remnants deposited on the electrode.