Ailke Behrens

Ms. Ailke Behrens

Medizinische Hochschule Hannover

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KFKatharina Foremny
Katharina Foremny
WKWiebke S. Konerding
Wiebke S. Konerding
Ailke BehrensAilke Behrens
Ailke Behrens
PBPeter Baumhoff
Peter Baumhoff
UFUlrich P Froriep
Ulrich P Froriep
TDTheodor Doll
Theodor Doll
Current developments of electrodes for neural recordings address the need of biomedical research and applications for high spatial acuity in electrophysiological recordings. One approach is the usage of novel materials to overcome electrochemical constraints of state-of-the-art metal contacts. Promising materials are carbon nanotubes (CNTs), as they are well suited for neural interfacing. The CNTs increase the effective contact surface area to decrease high impedances while keeping minimal contact diameters. However, to prevent toxic dissolving of CNTs, an appropriate surface coating is required. In this study, we tested flexible surface electrocorticographic (ECoG) electrodes, coated with a CNT-silicone rubber composite. First, we describe the outcome of surface etching, which exposes the contact nanostructure while anchoring the CNTs. Subsequently, the ECoG electrodes were used for acute in vivo recordings of auditory evoked potentials from the guinea pig auditory cortex. Both the impedances and the signal-to-noise ratios of coated contacts were similar to uncoated gold contacts. This novel approach for a safe application of CNTs, embedded in a surface etched silicone rubber, showed promising results but did not lead to improvements during acute recordings.

3 July 2018 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
Ailke BehrensAilke Behrens
Ailke Behrens
KFKatharina Foremny
Katharina Foremny
TDTheodor Doll
Theodor Doll

19 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Ailke BehrensAilke Behrens
Ailke Behrens
JSJan Stieghorst
Jan Stieghorst
TDTheodor Doll
Theodor Doll
UFUlrich P Froriep
Ulrich P Froriep
Current personalized treatment of neurological diseases is limited by availability of appropriate manufacturing methods suitable for long term sensors for neural electrical activities in the brain. An additive manufacturing process for polymer-based biocompatible neural sensors for chronic application towards individualized implants is here presented. To process thermal crosslinking polymers, the developed extrusion process enables, in combination with an infrared (IR)-Laser, accelerated curing directly after passing the outlet of the nozzle. As a result, no additional curing steps are necessary during the build-up. Furthermore, the minimal structure size can be achieved using the laser and, in combination with the extrusion parameters, provide structural resolutions desired. Active implant components fabricated using biocompatible materials for both conductive pathways and insulating cladding keep their biocompatible properties even after the additive manufacturing process. In addition, first characterization of the electric properties in terms of impedance towards application in neural tissues are shown. The printing toolkit developed enables processing of low-viscous, flexible polymeric thermal curing materials for fabrication of individualized neural implants.