Theodor Doll

Theodor Doll


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KFKatharina Foremny
Katharina Foremny
Steven NagelsSteven Nagels
Steven Nagels
MKMichaela Kreienmeyer
Michaela Kreienmeyer
TDTheodor Doll
Theodor Doll
Wim DefermeWim Deferme
Wim Deferme
Galinstan, a liquid metal at room temperature, is a promising material for use in flexible electronics. Since it has been successfully integrated in devices for external use, e.g., as stretchable electronic skin in tactile sensation, the possibility of using galinstan for flexible implant technology comes to mind. Usage of liquid metals in a flexible implant would reduce the risk of broken conductive pathways in the implants and therefore reduce the possibility of implant failure. However, the biocompatibility of the liquid metal under study, i.e., galinstan, has not been proven in state-of-the-art literature. Therefore, in this paper, a material combination of galinstan and silicone rubber is under investigation regarding the success of sterilization methods and to establish biocompatibility testing for an in vivo application. First cell biocompatibility tests (WST-1 assays) and cell toxicity tests (LDH assays) show promising results regarding biocompatibility. This work paves the way towards the successful integration of stretchable devices using liquid metals embedded in a silicone rubber encapsulant for flexible surface electro-cortical grid arrays and other flexible implants.

17 April 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KFKatharina Foremny
Katharina Foremny
WKWiebke S. Konerding
Wiebke S. Konerding
Ailke BehrensAilke Behrens
Ailke Behrens
PBPeter Baumhoff
Peter Baumhoff
UFUlrich P Froriep
Ulrich P Froriep
TDTheodor Doll
Theodor Doll
Current developments of electrodes for neural recordings address the need of biomedical research and applications for high spatial acuity in electrophysiological recordings. One approach is the usage of novel materials to overcome electrochemical constraints of state-of-the-art metal contacts. Promising materials are carbon nanotubes (CNTs), as they are well suited for neural interfacing. The CNTs increase the effective contact surface area to decrease high impedances while keeping minimal contact diameters. However, to prevent toxic dissolving of CNTs, an appropriate surface coating is required. In this study, we tested flexible surface electrocorticographic (ECoG) electrodes, coated with a CNT-silicone rubber composite. First, we describe the outcome of surface etching, which exposes the contact nanostructure while anchoring the CNTs. Subsequently, the ECoG electrodes were used for acute in vivo recordings of auditory evoked potentials from the guinea pig auditory cortex. Both the impedances and the signal-to-noise ratios of coated contacts were similar to uncoated gold contacts. This novel approach for a safe application of CNTs, embedded in a surface etched silicone rubber, showed promising results but did not lead to improvements during acute recordings.

1 February 2022 in Neural Networks
Verified
Journal Article
Closed access
AAAli Abdul Nabi Ali
Ali Abdul Nabi Ali
MAMesbah Alam
Mesbah Alam
SKSimon C. Klein
Simon C. Klein
NBNicolai Behmann
Nicolai Behmann
JKJoachim K. Krauss
Joachim K. Krauss
KSKerstin Schwabe
Kerstin Schwabe

8 June 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YMYuyang Mao
Yuyang Mao
IPIvan Pechenizkiy
Ivan Pechenizkiy
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
TDTheodor Doll
Theodor Doll
The most common failure mode of implantable neural implants has been delamination of layers in compound structures and encapsulations in a wet body environment. Current knowledge of failure mechanisms of adhesion and its standardized test procedures are lacking and must be established. This study demonstrated a combined experimental and numerical method to investigate the residual stresses from one of the most common encapsulation materials, silicone rubber (polydimethylsiloxane-PDMS) during the coating process at elevated temperatures. Measured shrinkage of test specimen correlates well to a modified shrinkage model using thermal-mechanical finite element method (FEM) simulation. All simulated interfacial stresses show stress concentration at the PDMS coating front depending on curing temperature and coating thickness, while Griffith’s condition estimated the delamination of the coating front. This study emphasizes the understanding of the interfacial delamination giving the possibility to predict failure mode of neural interface.

31 December 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
Adrian OnkenAdrian Onken
Adrian Onken
HSHelmut Schütte
Helmut Schütte
AWAnika Wulff
Anika Wulff
HLHeidi Lenz-Strauch
Heidi Lenz-Strauch
MKMichaela Kreienmeyer
Michaela Kreienmeyer
TDTheodor Doll
Theodor Doll
The ingress of body fluids or their constituents is one of the main causes of failure of active implantable medical devices (AIMDs). Progressive delamination takes its origin at the junctions where exposed electrodes and conductive pathways enter the implant interior. The description of this interface is considered challenging because electrochemically-diffusively coupled processes are involved. Furthermore, standard tests and specimens, with clearly defined 3-phase boundaries (body fluid-metal-polymer), are lacking. We focus on polymers as substrate and encapsulation and present a simple method to fabricate reliable test specimens with defined boundaries. By using silicone rubber as standard material in active implant encapsulation in combination with a metal surface, a corrosion-triggered delamination process was observed that can be universalised towards typical AIMD electrode materials. Copper was used instead of medical grade platinum since surface energies are comparable but corrosion occurs faster. The finding is that two processes are superimposed there: First, diffusion-limited chemical reactions at interfaces that undermine the layer adhesion. The second process is the influx of ions and body fluid components that leave the aqueous phase and migrate through the rubber to internal interfaces. The latter observation is new for active implants. Our mathematical description with a Stefan-model coupled to volume diffusion reproduces the experimental data in good agreement and lends itself to further generalisation.

26 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
SYSuheda Yilmaz-Bayraktar
Suheda Yilmaz-Bayraktar
KFKatharina Foremny
Katharina Foremny
MKMichaela Kreienmeyer
Michaela Kreienmeyer
AWAthanasia Warnecke
Athanasia Warnecke
TDTheodor Doll
Theodor Doll
The gold standard for the partial restoration of sensorineural hearing loss is cochlear implant surgery, which restores patients’ speech comprehension. The remaining limitations, e.g., music perception, are partly due to a gap between cochlear implant electrodes and the auditory nerve cells in the modiolus of the inner ear. Reducing this gap will most likely lead to improved cochlear implant performance. To achieve this, a bending or curling mechanism in the electrode array is discussed. We propose a silicone rubber–hydrogel actuator where the hydrogel forms a percolating network in the dorsal silicone rubber compartment of the electrode array to exert bending forces at low volume swelling ratios. A material study of suitable polymers (medical-grade PDMS and hydrogels), including parametrized bending curvature measurements, is presented. The curvature radii measured meet the anatomical needs for positioning electrodes very closely to the modiolus. Besides stage-one biocompatibility according to ISO 10993-5, we also developed and validated a simplified mathematical model for designing hydrogel-actuated CI with modiolar hugging functionality.