Jiazhen Han

Dr. Jiazhen Han


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2022 in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
Verified
Journal Article
Closed access
GZGuanghui Zhang
Guanghui Zhang
KXKefan Xu
Kefan Xu
JHJiazhen Han
Jiazhen Han
YHYanzhong Huang
Yanzhong Huang
WGWenjie Gong
Wenjie Gong
BLBo Liang
Bo Liang
Both foil structure and surface texturing have been widely used to improve bearing performance. However, there is little research on their combination, namely, textured gas foil bearing. This paper adopts the Reynolds equation as the pressure governing equation of bump-type foil journal bearing to study the influence of textures located on the top foil. The Newton-Raphson iterative method and the perturbation method are employed to obtain static and dynamic characteristics, respectively. Thereafter, based on three texture distribution types, further analysis about the effect of the relative texture depth and the textured portion is carried out. The results indicate that an appropriate arrangement of textures could improve the performance of gas foil bearing. For #1 texture distribution, the maximum increment of load capacity could exceed 10% when ω = 1.4 × 105 r/min, ε = 0.2.

28 September 2022 in Energy Reports
Verified
Journal Article
Open access
JHJiazhen Han
Jiazhen Han
YXYudong Xie
Yudong Xie
YWYong Wang
Yong Wang
QWQixian Wang
Qixian Wang
YZYubing Zhang
Yubing Zhang
ZPZihan Pan
Zihan Pan

19 April 2021 in Science and Technology of Nuclear Installations
Verified
Journal Article
Open access
PDF file
JHJiazhen Han
Jiazhen Han
YXYudong Xie
Yudong Xie
YWYong Wang
Yong Wang
QWQixian Wang
Qixian Wang
Control valves have an important function in the warship power system. In engineering practice, the fluid oscillation inside the control valve causes the additional load to the valve actuator. When the additional load is added to the original load of the valve, it is possible that the required driving force (or driving moment) of the valve is greater than the maximum force (or moment) output by the actuator, which may cause the abnormal stop of the actuator. Conventionally, the interaction effect of the valve mechanical and electric components on the valve chamber’s flow field cannot be considered in computational fluid dynamics (CFD) simulations, so the oscillating fluid loads cannot be accurately obtained. In order to solve this problem, the mechanical-electric-fluid integrated valve model, using the FLUENT and AMESim cosimulation method, was developed to embody the interaction effect between the components of each part of the control valve and exhibit the fluid oscillation during the operating process of the control valve. Compared with the pure software simulations, the unsteady flow characteristics and dynamic response of the actuator were synchronously obtained in this study, which accurately captured the sudden fluid loads required for further compensation. At the same time, the differences in performance of different valve plugs were compared. The stability time of the valve plug and oscillation amplitude of the unstable fluid loads were distinct for control valves with different flow characteristics. The results can aid in understanding the instability mechanism of the fluid load in the control valve better, which provides the calculation basis for compensating the additional load on the valve plug and improve the reliability of the control valve.

24 March 2025 in Actuators
Verified
Journal Article
Open access
PDF file
HJHexi Ji
Hexi Ji
JHJiazhen Han
Jiazhen Han
YWYong Wang
Yong Wang
YLYongkang Liu
Yongkang Liu
YXYudong Xie
Yudong Xie
YSYilong Song
Yilong Song
Laver fluffy is an indispensable link in the processing of laver products. After fluffing, the laver acquires an appealing color, which is conducive to better marketability. During the primary mechanical processing of laver, a valve capable of rapid opening and closing is required to ensure that the laver’s surface becomes fluffy and lustrous post-processing. However, valve products that can meet the specific requirements of laver fluffing are scarce. This study proposes a novel principle for a high-speed switching control valve. This valve can quickly turn on or cut off the high-pressure gas path during laver processing while also taking into account the response speed and service life. The structure and principle of the new control valve were introduced. Different flow field models in the valve were designed, and their flow characteristics and flow field performance under various schemes were compared and discussed by using Fluent. Subsequently, an optimized control valve structure model was proposed. Based on this, a strength analysis of the control valve was conducted via fluid–structure interaction, revealing the response characteristics of the valve under the working state. The results indicate that, when different cone angles and bell shapes were selected for the upper chamber inlet of the control valve, the number and intensity of vortices in the upper chamber can be reduced. The height of the upper chamber affected the formation of the throttle between the top and bottom surfaces of the upper chamber. When the height of the upper chamber was 32 mm, the energy loss in the upper chamber remains basically stable. Simultaneously changing the inlet shape and height of the upper chamber can effectively prevent the throttle formed by the height of the upper chamber, which was conducive to increasing the valve outlet flow rate. Through the analysis of the flow field with different valve chamber structures, the improved control valve adopted the bell-shaped inlet, with an upper chamber height of 32 mm and curved transition for the internal flow channel. Compared to the original fluid domain, when the opening was 100%, the outlet flow rate of the 10° conical tube and bell-shaped inlet increased by 12.77% and 12.59%, respectively. The outlet flow rate at the curved transition position rose by 15.35%, and the outlet flow of the improved control valve increased by 32.70%. When the control valve was operating under a preload pressure of 1 MPa, at 20% opening, the maximum equivalent stress of the valve body was 52.51 MPa, and the total deformation was 12.56 microns. When the preload pressure exceeded 1.5 MPa, the equivalent stress and total deformation of the control valve body and T-shaped valve stem exhibited an upward trend with further increases in the preload pressure.

6 June 2024 in Actuators
Verified
Journal Article
Open access
PDF file
HJHexi Ji
Hexi Ji
JHJiazhen Han
Jiazhen Han
YWYong Wang
Yong Wang
QWQixian Wang
Qixian Wang
SYSen Yang
Sen Yang
HWHaibo Wang
Haibo Wang
Modern laver fluffiness is achieved by applying high-speed gas to a laver, which is generated by the opening and closing of a laver fluffiness control valve in a fluffiness system. To address the problems of the slow response speed and poor stability of valves used in the laver processing industry at present, this paper proposes a novel principle of a high-speed switching control valve, which has the advantages of a fast response speed, high stability, and long service life. The structure and working principle of the control valve are introduced, and the calculation equation of the valve’s flow area is established. The flow field inside the control valve with different openings was numerically calculated in this study using Fluent. The flow regulation characteristics and flow field performance of the control valve were also analyzed. The results show that, with an increase in the valve opening, the influence of the flow area at the valve throttle on the valve flow rate was weakened. When the valve was opened, a vortex appeared in both the upper and lower cavities, and jet flow occurred at the throttle of the middle flow channel. As the valve opening increased, the pressure in the upper cavity reduced, while the pressure in the lower cavity increased. The vortex in the flow field intensified, and the jet phenomenon at the valve throttle gradually disappeared. At the same time, the main stream in the lower cavity gradually changed from an annular flow to a direct flow toward the valve outlet. Furthermore, the impact, collision, and vortex formation of the fluid caused energy loss of the fluid, leading to a decrease in the outlet flow of the control valve.

1 February 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
JHJiazhen Han
Jiazhen Han
YXYudong Xie
Yudong Xie
YWYong Wang
Yong Wang
ZPZihan Pan
Zihan Pan
An underwater valve at 3000 meters underwater was chosen as the research object, aiming at obtaining the force characteristics of the underwater valve under high pressure and large temperature difference in the deep sea. The principle of fluid-solid-thermal three-field coupling was analyzed by using Fluent and ANSYS Workbench. Through numerical simulation, the fluid temperature distribution, the stress and deformation of the valve were obtained, and the valve was loaded. The influence of pressure and temperature on the performance of underwater valve was discussed. The results show that the fluid medium inside and outside the valve exchanged heat due to the large temperature difference, and vortexes were generated at the bottom of the valve seat, and the fluid pressure energy was converted into heat energy. The force of thermal stress generated by heat exchange on the valve body was greater than the equivalent stress generated by thermal-mechanical load.