Sen Yang

Sen Yang

Auto-generated profile, based on publicly available information

Sen Yang

School of Mechanical Engineering, Shandong University, Jinan 250061, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2024 in Actuators
Verified
Journal Article
Open access
PDF file
HJHexi Ji
Hexi Ji
JHJiazhen Han
Jiazhen Han
YWYong Wang
Yong Wang
QWQixian Wang
Qixian Wang
SYSen Yang
Sen Yang
HWHaibo Wang
Haibo Wang
Modern laver fluffiness is achieved by applying high-speed gas to a laver, which is generated by the opening and closing of a laver fluffiness control valve in a fluffiness system. To address the problems of the slow response speed and poor stability of valves used in the laver processing industry at present, this paper proposes a novel principle of a high-speed switching control valve, which has the advantages of a fast response speed, high stability, and long service life. The structure and working principle of the control valve are introduced, and the calculation equation of the valve’s flow area is established. The flow field inside the control valve with different openings was numerically calculated in this study using Fluent. The flow regulation characteristics and flow field performance of the control valve were also analyzed. The results show that, with an increase in the valve opening, the influence of the flow area at the valve throttle on the valve flow rate was weakened. When the valve was opened, a vortex appeared in both the upper and lower cavities, and jet flow occurred at the throttle of the middle flow channel. As the valve opening increased, the pressure in the upper cavity reduced, while the pressure in the lower cavity increased. The vortex in the flow field intensified, and the jet phenomenon at the valve throttle gradually disappeared. At the same time, the main stream in the lower cavity gradually changed from an annular flow to a direct flow toward the valve outlet. Furthermore, the impact, collision, and vortex formation of the fluid caused energy loss of the fluid, leading to a decrease in the outlet flow of the control valve.

24 March 2025 in Actuators
Verified
Journal Article
Open access
PDF file
HJHexi Ji
Hexi Ji
JHJiazhen Han
Jiazhen Han
YWYong Wang
Yong Wang
YLYongkang Liu
Yongkang Liu
YXYudong Xie
Yudong Xie
YSYilong Song
Yilong Song
Laver fluffy is an indispensable link in the processing of laver products. After fluffing, the laver acquires an appealing color, which is conducive to better marketability. During the primary mechanical processing of laver, a valve capable of rapid opening and closing is required to ensure that the laver’s surface becomes fluffy and lustrous post-processing. However, valve products that can meet the specific requirements of laver fluffing are scarce. This study proposes a novel principle for a high-speed switching control valve. This valve can quickly turn on or cut off the high-pressure gas path during laver processing while also taking into account the response speed and service life. The structure and principle of the new control valve were introduced. Different flow field models in the valve were designed, and their flow characteristics and flow field performance under various schemes were compared and discussed by using Fluent. Subsequently, an optimized control valve structure model was proposed. Based on this, a strength analysis of the control valve was conducted via fluid–structure interaction, revealing the response characteristics of the valve under the working state. The results indicate that, when different cone angles and bell shapes were selected for the upper chamber inlet of the control valve, the number and intensity of vortices in the upper chamber can be reduced. The height of the upper chamber affected the formation of the throttle between the top and bottom surfaces of the upper chamber. When the height of the upper chamber was 32 mm, the energy loss in the upper chamber remains basically stable. Simultaneously changing the inlet shape and height of the upper chamber can effectively prevent the throttle formed by the height of the upper chamber, which was conducive to increasing the valve outlet flow rate. Through the analysis of the flow field with different valve chamber structures, the improved control valve adopted the bell-shaped inlet, with an upper chamber height of 32 mm and curved transition for the internal flow channel. Compared to the original fluid domain, when the opening was 100%, the outlet flow rate of the 10° conical tube and bell-shaped inlet increased by 12.77% and 12.59%, respectively. The outlet flow rate at the curved transition position rose by 15.35%, and the outlet flow of the improved control valve increased by 32.70%. When the control valve was operating under a preload pressure of 1 MPa, at 20% opening, the maximum equivalent stress of the valve body was 52.51 MPa, and the total deformation was 12.56 microns. When the preload pressure exceeded 1.5 MPa, the equivalent stress and total deformation of the control valve body and T-shaped valve stem exhibited an upward trend with further increases in the preload pressure.