This paper proposes a computational technique for the classification of electricity consumption profiles. The methodology is comprised of two steps. In the first one, a C-means-based fuzzy clustering is performed in order to find consumers with similar consumption profiles. Afterwards, a fuzzy classification is performed using a fuzzy membership matrix and the Euclidean distance to the cluster centers. Then, the distance measures are normalized and ordered, yielding a unitary index score, where the potential fraudsters or users with irregular patterns of consumption have the highest scores. The approach was tested and validated on a real database, showing good performance in tasks of fraud and measurement defect detection.
Reduced external networks supplied with real-time data are employed in this paper to solve the state estimation problem in interconnected systems. We propose a method to obtain a composed single system state of different monitored areas with local estimations and external equivalent models, which neither require the use of a coordination agent nor requires extensive data interchange. Phasor measurement unit (PMU) measurements taken from system boundaries are used to provide updated equivalent networks as well as an inter-area synchronism. The approach allows testing erroneous external models directly in the state estimation framework. The detectability of bad data in interconnection measurements are also preserved. Tests with the IEEE 118-bus and IEEE 300-bus systems show robustness and accuracy of the model under different area decomposition schemes with low computational requirements compared to similar conventional approaches.
Transmission line parameters are usually calculated based on technical and environmental approximations, e.g. line height, cable conductivity, etc. These characteristics vary depending on the environment and technical issues, meaning that the transmission line should be considered as a dynamic system with time-varying parameters. Estimation methods are a useful way to determine line parameters taken into account such characteristics. Most methods estimate these parameters at 50 ~ 60 Hz, useful for steady state analysis. However, for transient state or harmonic distortion analyses, a frequency range should be estimated, which varies according to the phenomenon to be investigated. In this matter, considering the gap existent of studies to estimate frequency-dependent parameters, we propose an efficacious and simplified method based on the two-port line representation and the well-known least squares method to estimate these parameters of a transmission line with 400 km length, considering a minimum number of synchronized measurements from 1 Hz up to 250 Hz.
A state estimation based approach to obtain an external network equivalent and track topology changes is developed in this work. The proposed approach enables real-time detection and identification of topology-based external events. Following an orthogonal parameter estimator, an index related to the measurement residuals is tracked to detect external disturbances, which are classified based on reference values and actual system data. The method makes use of boundary bus voltages, external currents, an initial snapshot of the network topology, as well as the sensitivity of external changes to the equivalent network. Tests on the IEEE 300-bus and Brazilian 6092-bus systems highlight its capabilities in detecting and identifying shunt, single and double line outages and insertion events.
With the growth of inter-utilities power exchanges and the spread of new and rapid monitoring technologies, the efficient modeling of external networks becomes crucial for a reliable and secure operation. This paper investigates the problem of bad data in interconnected networks when real-time evaluated external equivalents are attached. It is shown that, under this scenario, regular techniques of bad data detection can be applied for detecting and recovering corrupted and outdated external equivalent data. The approach is validated using the IEEE 118-bus system and a Ward Equivalent model. The results demonstrate that the adjusted equivalent networks have good agreement with the expected values, also keeping bad data on interconnection measurements detectable.