Vladimir Vitkin

Dr. Vladimir Vitkin


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
ATArtem Tabarov
Artem Tabarov
VVVladimir Vitkin
Vladimir Vitkin
OAOlga Valerievna Andreeva
Olga Valerievna Andreeva
ASArina Shemanaeva
Arina Shemanaeva
EPEvgeniy Popov
Evgeniy Popov
DDDaria Danilenko
Daria Danilenko
We demonstrate the possibility of applying surface-enhanced Raman spectroscopy (SERS) combined with machine learning technology to detect and differentiate influenza type A and B viruses in a buffer environment. The SERS spectra of the influenza viruses do not possess specific peaks that allow for their straight classification and detection. Machine learning technologies (particularly, the support vector machine method) enabled the differentiation of samples containing influenza A and B viruses using SERS with an accuracy of 93% at a concentration of 200 μg/mL. The minimum detectable concentration of the virus in the sample using the proposed approach was ~0.05 μg/mL of protein (according to the Lowry protein assay), and the detection accuracy of a sample with this pathogen concentration was 84%.

24 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VVVladimir Vitkin
Vladimir Vitkin
APAnton Polishchuk
Anton Polishchuk
ICIan Chubchenko
Ian Chubchenko
EPEvgeniy Popov
Evgeniy Popov
KGKonstantin Grigorenko
Konstantin Grigorenko
XFXavier Mateos Ferré
Xavier Mateos Ferré
A compact Raman laser gas spectrometer is developed. It comprises a high-power green laser at 532.123 nm as an excitation source and a specially designed gas cell with an internal volume of less than 0.6 cm3 that can withstand gas pressures up to 100 atm. The resolution of the spectrometer is ~1 cm−1. The Raman spectra of chemically pure isotopically enriched carbon dioxide (12CO2, 13CO2) and methane (12CH4, 13CH4) gases are studied. The expected limit of detection (LOD) is less than 100 ppm for the isotopologues of CO2 and less than 25 ppm for those of CH4 (at a gas pressure of 50 atm.), making the developed spectrometer promising for studying the sources of emissions of greenhouse gases by resolving their isotopologue composition. We also show the suitability of the spectrometer for Raman spectroscopy of human exhalation.

16 November 2016 in Laser Physics
Verified
Journal Article
Closed access
PDF file
VVVladimir Vitkin
Vladimir Vitkin
VPV M Polyakov
V M Polyakov
AKA A Kharitonov
A A Kharitonov
VBV A Buchenkov
V A Buchenkov
ARA Yu Rodionov
A Yu Rodionov
PLPavel Loiko
Pavel Loiko
We report on the development of a compact diode-end-pumped eye-safe (~1.54 µm) passively-cooled Er,Yb:glass laser. The design of this laser is facilitated by the use of a double-pass pumping scheme and a special ZrO2 diffuse reflector for a uniform pump distribution. In the free-running mode, this laser generates 8.2 mJ/3 ms pulses with a slope efficiency of 15%. Passive Q-switching is provided by saturable absorbers made of transparent glass-ceramics containing Co2+:γ-Ga2O3 or Co2+:MgAl2O4 nanocrystals with a spinel structure. In the latter case, 0.7 mJ/10.5 ns pulses are generated corresponding to >60 kW peak power and good beam quality (M 2 = 1.4). The designed laser is suitable for portable range-finders.

2 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
EPEvgeniy Popov
Evgeniy Popov
APAnton Polishchuk
Anton Polishchuk
AKAnton Kovalev
Anton Kovalev
VVVladimir Vitkin
Vladimir Vitkin
The urea breath test is a non-invasive diagnostic method for Helicobacter pylori infections, which relies on the change in the proportion of 13CO2 in exhaled air. Nondispersive infrared sensors are commonly used for the urea breath test in laboratory equipment, but Raman spectroscopy demonstrated potential for more accurate measurements. The accuracy of the Helicobacter pylori detection via the urea breath test using 13CO2 as a biomarker is affected by measurement errors, including equipment error and δ13C measurement uncertainty. We present a Raman scattering-based gas analyzer capable of δ13C measurements in exhaled air. The technical details of the various measurement conditions have been discussed. Standard gas samples were measured. 12CO2 and 13CO2 calibration coefficients were determined. The Raman spectrum of the exhaled air was measured and the δ13C change (in the process of the urea breath test) was calculated. The total error measured was 6% and does not exceed the limit of 10% that was analytically calculated.

17 February 2017
Verified
Conference Paper
Closed access
PDF file
VVVladimir Vitkin
Vladimir Vitkin
ODOlga S. Dymshits
Olga S. Dymshits
VPVadim M. Polyakov
Vadim M. Polyakov
AZAlexander A. Zhilin
Alexander A. Zhilin
DSDarya V. Shemchuk
Darya V. Shemchuk
AKAnton Kovalev
Anton Kovalev

1 June 2014
Verified
Conference Paper
Closed access
VPVadim M. Polyakov
Vadim M. Polyakov
VVVladimir Vitkin
Vladimir Vitkin
DLDmitriy I. Lychagin
Dmitriy I. Lychagin
AKAleksandr A. Krylov
Aleksandr A. Krylov
VBVyacheslav A. Buchenkov
Vyacheslav A. Buchenkov
SKSergey V. Kashcheev
Sergey V. Kashcheev
A compact laser for airborne lidar was developed. Laser wavelength is 1047 nm and it's suggested further to pump SHG and FHG. Pulse energy is 100 mJ Q-switched, repetition rate is 250 Hz. We use efficient pump system with 67% absorption efficiency, fluid coolant for laser rods and laser diodes. The laser head volume is 5 cube decimeter.