Tyler Salvador

Tyler Salvador

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2021 in Surgical Innovation
Verified
Journal Article
Closed access
PDF file
JOJustin Opfermann
Justin Opfermann
ADAnuradha Dayal
Anuradha Dayal
AAAlyssa Abo
Alyssa Abo
ETEmily Thatcher
Emily Thatcher
TSTyler Salvador
Tyler Salvador
KCKevin R Cleary
Kevin R Cleary
The COVID-19 pandemic has affected life for everyone, and hospitals, in particular have been hard hit. In this study, we describe our efforts to develop personal protective equipment at a children’s hospital early in the pandemic. We convened an innovation working group to organize our efforts and respond to the rapidly changing situation. We describe our work in four areas: (1) plexiglass shields for the emergency department, (2) face shields for clinical providers, (3) breath shields for ophthalmology, and (4) flip-up safety glasses for nurses. The hospital’s supply chain is now caught up with addressing many pandemic-related shortages. Nevertheless, through our multidisciplinary approach to reacting to the pandemic’s urgent needs, we demonstrated agility to bring stakeholders together to maximize the use of scarce resources and build resiliency. We believe this method can be rapidly replicated as future needs arise.

20 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YAYouness Arjoune
Youness Arjoune
Trong-The NguyenTrong-The Nguyen
Trong-The Nguyen
TSTyler Salvador
Tyler Salvador
ATAnha Telluri
Anha Telluri
JSJonathan C. Schroeder
Jonathan C. Schroeder
RSRaj Shekhar
Raj Shekhar
(1) Background: Mastery of auscultation can be challenging for many healthcare providers. Artificial intelligence (AI)-powered digital support is emerging as an aid to assist with the interpretation of auscultated sounds. A few AI-augmented digital stethoscopes exist but none are dedicated to pediatrics. Our goal was to develop a digital auscultation platform for pediatric medicine. (2) Methods: We developed StethAid—a digital platform for artificial intelligence-assisted auscultation and telehealth in pediatrics—that consists of a wireless digital stethoscope, mobile applications, customized patient-provider portals, and deep learning algorithms. To validate the StethAid platform, we characterized our stethoscope and used the platform in two clinical applications: (1) Still’s murmur identification and (2) wheeze detection. The platform has been deployed in four children’s medical centers to build the first and largest pediatric cardiopulmonary datasets, to our knowledge. We have trained and tested deep-learning models using these datasets. (3) Results: The frequency response of the StethAid stethoscope was comparable to those of the commercially available Eko Core, Thinklabs One, and Littman 3200 stethoscopes. The labels provided by our expert physician offline were in concordance with the labels of providers at the bedside using their acoustic stethoscopes for 79.3% of lungs cases and 98.3% of heart cases. Our deep learning algorithms achieved high sensitivity and specificity for both Still’s murmur identification (sensitivity of 91.9% and specificity of 92.6%) and wheeze detection (sensitivity of 83.7% and specificity of 84.4%). (4) Conclusions: Our team has created a technically and clinically validated pediatric digital AI-enabled auscultation platform. Use of our platform could improve efficacy and efficiency of clinical care for pediatric patients, reduce parental anxiety, and result in cost savings.

19 October 2020 in Informatics
Verified
Journal Article
Open access
PDF file
MSManon Maitland Schladen
Manon Maitland Schladen
KCKevin Cleary
Kevin Cleary
YKYiannis Koumpouros
Yiannis Koumpouros
RMReza Monfaredi
Reza Monfaredi
TSTyler Salvador
Tyler Salvador
SESarah Helen Evans
Sarah Helen Evans
Technological advances in game-mediated robotics provide an opportunity to engage children with cerebral palsy (CP) and other neuromotor disabilities in more frequent and intensive therapy by making personalized, programmed interventions available 24/7 in children’s homes. Though shown to be clinically effective and feasible to produce, little is known of the subjective factors impacting acceptance of what we term assistive/rehabilitative (A/R) gamebots by their target populations. This research describes the conceptualization phase of an effort to develop a valid and reliable instrument to guide the design of A/R gamebots. We conducted in-depth interviews with 8 children with CP and their families who had trialed an exemplar A/R gamebot, PedBotHome, for 28 days in their homes. The goal was to understand how existing theories and instruments were either appropriate or inappropriate for measuring the subjective experience of A/R gamebots. Key findings were the importance of differentiating the use case of therapy from that of assistance in rehabilitative technology assessment, the need to incorporate the differing perspectives of children with CP and those of their parents into A/R gamebot evaluation, and the potential conflict between the goals of preserving the quality of the experience of game play for the child while also optimizing the intensity and duration of therapy provided during play.

11 April 2022 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
PRPooneh Roshanitabrizi
Pooneh Roshanitabrizi
AKAnita Krishnan
Anita Krishnan
CICatherine Ingbar
Catherine Ingbar
TSTyler Salvador
Tyler Salvador
AZAnqing Zhang
Anqing Zhang
RGRathinaswamy B Govindan
Rathinaswamy B Govindan
Fetal electrocardiogram (ECG) waveform analysis along with cardiac time intervals (CTIs) measurements are critical for the management of high-risk pregnancies. Currently, there is no system that can consistently and accurately measure fetal ECG. In this work, we present a new automatic approach to attenuate the maternal ECG in the frequency domain and enhance it with measurable CTIs. First, the coherent components between the maternal ECG and abdominal ECG were identified and subtracted from the latter in the frequency domain. The residual was then converted into the time domain using the inverse Fourier transform to yield the fetal ECG. This process was improved by averaging multiple beats. Two fetal cardiologists, blinded to the method, assessed the quality of fetal ECG based on a grading system and measured the CTIs. We evaluated the fetal ECG quality of our method and time-based methods using one synthetic dataset, one human dataset available in the public domain, and 37 clinical datasets. Among the 37 datasets analyzed, the mean average (± standard deviation) grade was 3.49 ± 1.22 for our method vs. 2.64 ± 1.26 for adaptive interference cancellation (p-value < 0.001), thus showing the frequency-based fetal ECG extraction was the superior method, as assessed from our clinicians’ perspectives. This method has the potential for use in clinical settings.

13 September 2024 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
GZGesiren Zhang
Gesiren Zhang
Trong-The NguyenTrong-The Nguyen
Trong-The Nguyen
HFHadi Fooladi-Talari
Hadi Fooladi-Talari
TSTyler Salvador
Tyler Salvador
KTKia Thomas
Kia Thomas
RSRaj Shekhar
Raj Shekhar
SignificanceConventional ultrasound-guided vascular access procedures are challenging due to the need for anatomical understanding, precise needle manipulation, and hand–eye coordination. Recently, augmented reality (AR)-based guidance has emerged as an aid to improve procedural efficiency and potential outcomes. However, its application in pediatric vascular access has not been comprehensively evaluated.AimWe developed an AR ultrasound application, HoloUS, using the Microsoft HoloLens 2 to display live ultrasound images directly in the proceduralist’s field of view. We presented our evaluation of the effect of using the Microsoft HoloLens 2 for point-of-care ultrasound (POCUS)-guided vascular access in 30 pediatric patients.ApproachA custom software module was developed on a tablet capable of capturing the moving ultrasound image from any ultrasound machine’s screen. The captured image was compressed and sent to the HoloLens 2 via a hotspot without needing Internet access. On the HoloLens 2, we developed a custom software module to receive, decompress, and display the live ultrasound image. Hand gesture and voice command features were implemented for the user to reposition, resize, and change the gain and the contrast of the image. We evaluated 30 (15 successful control and 12 successful interventional) cases completed in a single-center, prospective, randomized study.ResultsThe mean overall rendering latency and the rendering frame rate of the HoloUS application were 139.30 ms (σ=32.02 ms) and 30 frames per second, respectively. The average procedure completion time was 17.3% shorter using AR guidance. The numbers of puncture attempts and needle redirections were similar between the two groups, and the number of head adjustments was minimal in the interventional group.ConclusionWe presented our evaluation of the results from the first study using the Microsoft HoloLens 2 that investigates AR-based POCUS-guided vascular access in pediatric patients. Our evaluation confirmed clinical feasibility and potential improvement in procedural efficiency.

13 March 2018
Verified
Conference Paper
Closed access
PDF file
RMReza Monfaredi
Reza Monfaredi
HFHadi Fooladi
Hadi Fooladi
PRPooneh Roshani
Pooneh Roshani
SKStaci Kovelman
Staci Kovelman
TSTyler Salvador
Tyler Salvador
KCKevin Cleary
Kevin Cleary
We have developed a three degree of freedom robot with a custom designed video game for ankle rehabilitation of children with cerebral palsy and other neuromuscular disorders. Physical therapy is commonly used to stretch and strengthen these patients, but current treatment methods have some limitations. By developing a robotic device and associated airplane video game, we aim to improve ankle range of motion, muscle strength, and motor control in a quantitative manner that is also fun and motivating for the child. Our PedBot robot consists of three intersecting axes with a remote center of motion in the ankle joint area. The patient’s ankle is strapped to PedBot and becomes a controller for the airplane game. The patient flies the plane through a series of rings and a bell sound is made each time the plane successfully passes through the center of a ring. To date we enrolled 4 children ages 4-11 in an IRB approved trial. The children completed up to 5 sessions. All of the children said they enjoyed the therapy. A 4-year old boy who completed all five sessions showed measureable improvements in several degrees of motion. We have also begun EMG based studies to investigate muscle activity during robotic rehabilitation.