Francisco David Moya

Francisco David Moya


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
JOSE EDUARDO FUENTES DELGADOJOSE EDUARDO FUENTES DELGADO
JOSE EDUARDO FUENTES DELGADO
FMFrancisco David Moya
Francisco David Moya
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
This study presents a method to estimate the solar energy potential based on 3D data taken from unmanned aerial devices. The solar energy potential on the roof of a building was estimated before the placement of solar panels using photogrammetric data analyzed in a geographic information system, and the predictions were compared with the data recorded after installation. The areas of the roofs were chosen using digital surface models and the hemispherical viewshed algorithm, considering how the solar radiation on the roof surface would be affected by the orientation of the surface with respect to the sun, the shade of trees, surrounding objects, topography, and the atmospheric conditions. The results show that the efficiency percentages of the panels and the data modeled by the proposed method from surface models are very similar to the theoretical efficiency of the panels. Radiation potential can be estimated from photogrammetric data and a 3D model in great detail and at low cost. This method allows the estimation of solar potential as well as the optimization of the location and orientation of solar panels.

13 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
FMFrancisco David Moya
Francisco David Moya
JTJose Torres
Jose Torres
José Domingo ÁlvarezJosé Domingo Álvarez
José Domingo Álvarez
The aim of this work was to develop an optimal model for an energy management strategy in a real micro-grid, which involves a smart building, a photovoltaic system with storage, and a plug-in full electric vehicle. A controller based on a mathematical algorithm was the core of each strategy, which directly acted on a relay board managing the interconnection between the different elements comprising the micro-grid. The development of an optimization model involving binary variables required an efficient code that achieved solutions in a short time. The analyzed case-study corresponded to the solar energy research center (CIESOL) smart building, a bioclimatic building, that is located at the University of Almería (Spain), designated to research in renewable energies. Using the methodologies described in this work, the total cost of the smart building energy consumption was minimized by decreasing the power supplied from the grid, especially at peak hours. Highlighting the use of a simple model that provided better performance than the current state of the art methodologies. The optimal model for energy management strategy demonstrated the advantages of using classical optimization techniques to solve this specific optimization problem, compared to a rule-based controller. The linear modeling was capable of producing a simple algorithm with less code development and a reduction in the computational effort.

19 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
JOSE EDUARDO FUENTES DELGADOJOSE EDUARDO FUENTES DELGADO
JOSE EDUARDO FUENTES DELGADO
FMFrancisco David Moya
Francisco David Moya
JGJose Angel Barrios Gomez
Jose Angel Barrios Gomez
RCRodrigo Chamorro
Rodrigo Chamorro
The problem of the optimal siting and placement of static compensates (STATCOMs) in power systems is addressed in this paper from an exact mathematical optimization point of view. A mixed-integer nonlinear programming model to present the problem was developed with the aim of minimizing the annual operating costs of the power system, which is the sum of the costs of the energy losses and of the installation of the STATCOMs. The optimization model has constraints regarding the active and reactive power balance equations and those associated with the devices’ capabilities, among others. To characterize the electrical behavior of the power system, different load profiles such as residential, industrial, and commercial are considered for a period of 24 h of operation. The solution of the proposed model is reached with the general algebraic modeling system optimization package. The numerical results indicate the positive effect of the dynamic reactive power injections in the power systems on annual operating cost reduction. A Pareto front was built to present the multi-objective behavior of the studied problem when compared to investment and operative costs. The complete numerical validations are made in the IEEE 24-, IEEE 33-, and IEEE 69-bus systems, respectively.

8 May 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
FMFrancisco David Moya
Francisco David Moya
ARArul Rajagopalan
Arul Rajagopalan
The minimization of annual operating costs in radial distribution networks with the optimal selection and siting of fixed-step capacitor banks is addressed in this research by means of a two-stage optimization approach. The first stage proposes an approximated mixed-integer quadratic model to select the nodes where the capacitor banks must be installed. In the second stage, a recursive power flow method is employed to make an exhaustive evaluation of the solution space. The main contribution of this research is the use of the expected load curve to estimate the equivalent annual grid operating costs. Numerical simulations in the IEEE 33- and IEEE 69-bus systems demonstrate the effectiveness of the proposed methodology in comparison with the solution of the exact optimization model in the General Algebraic Modeling System software. Reductions of 33.04% and 34.29% with respect to the benchmark case are obtained with the proposed two-stage approach, with minimum investments in capacitor banks. All numerical implementations are performed in the MATLAB software using the convex tool known as CVX and the Gurobi solver. The main advantage of the proposed hybrid optimization method lies in the possibility of dealing with radial and meshed distribution system topologies without any modification on the MIQC model and the recursive power flow approach.

25 January 2022 in Algorithms
Verified
Journal Article
Open access
PDF file
BABrayan Enrique Aguirre-Angulo
Brayan Enrique Aguirre-Angulo
LBLady Carolina Giraldo Bello
Lady Carolina Giraldo Bello
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
FMFrancisco David Moya
Francisco David Moya
This study addresses the problem of the maximization of the voltage stability index (λ-coefficient) in medium-voltage distribution networks considering the optimal placement and sizing of dispersed generators. The problem is formulated through a mixed-integer nonlinear programming model (MINLP), which is solved using General Algebraic Modeling System (GAMS) software. A numerical example with a 7-bus radial distribution network is employed to introduce the usage of GAMS software to solve the proposed MINLP model. A new validation methodology to verify the numerical results provided for the λ-coefficient is proposed by using recursive power flow evaluations in MATLAB and DigSILENT software. The recursive evaluations allow the determination of the λ-coefficient through the implementation of the successive approximation power flow method and the Newton–Raphson approach, respectively. It is effected by fixing the sizes and locations of the dispersed sources using the optimal solution obtained with GAMS software. Numerical simulations in the IEEE 33- and 69-bus systems with different generation penetration levels and the possibility of installing one to three dispersed generators demonstrate that the GAMS and the recursive approaches determine the same loadability index. Moreover, the numerical results indicate that, depending on the number of dispersed generators allocated, it is possible to improve the λ-coefficient between 20.96% and 37.43% for the IEEE 33-bus system, and between 18.41% and 41.98% for the IEEE 69-bus system.

1 August 2008
Verified
Conference Paper
Closed access
FMFrancisco David Moya
Francisco David Moya
GJGilberto De Martino Jannuzzi
Gilberto De Martino Jannuzzi
LSLuiz C. P. Da Silva
Luiz C. P. Da Silva
Among the ancillary services, the operating reserves are important researching aspects, which deal with supplying way and selling-buying prices. Currently, distributed generation (DG) rises as a new participant in providing ancillary services, therefore, it is of main importance in operating reserves subject. This work shows some advantages and technical drawbacks by using DG when operating reserves are supplied. Different sceneries were computed where the electric generation was performed in a centralized and non-centralized way respectively. A methodology for identifying the maximum DG, which can be allocated, is proposed; this maximum level can be assessed without carrying out a negative impact in the network. The operative reserves price provide by generation distribution is analyzed. Diverse DG technologies, which present better performance in supplying such reserves, are also presented.