Zhe Zhang

Dr. Zhe Zhang

Beijing forestry university, the School of Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZZZhe Zhang
Zhe Zhang
YZYuqi Zhang
Yuqi Zhang
XSXiaomei Sui
Xiaomei Sui
WLWenbin Li
Wenbin Li
DXDaochun Xu
Daochun Xu
Aiming to reduce thermal energy loss at the cold side of a thermoelectric generator (TEG) module during thermoelectric conversion, a thermoelectric energy conversion system for heat recovery with a water-cooling energy exchange circuit was devised. The water-cooling energy exchange circuit realized sufficient recovery and reuse of heat accumulated at the cold side of the TEG, reduced the danger of heat accumulation, improved the stability and output capacity of thermoelectric conversion, and provided a low-cost and high-yield energy conversion strategy in energy conversion and utilization. Through the control variable method to adjust the heat generation of the heat source in the thermoelectric conversion, critical parameters (e.g., inner resistance of the TEG, temperatures of thermoelectric modules, temperature differences, output current, voltage, power, and efficiency of thermoelectric conversion) were analyzed and discussed. After using the control variable method to change the ratio of load resistance and internal resistance, the impacts of the ratio of load resistance to inner resistance of the TEG on the entire energy conversion process were elaborated. The results showed that the maximum value of output reached 397.47 mV with a current of 105.56 mA, power of 41.96 mW, and energy conversion efficiency of 1.16%. The power density of the TEG module is 26.225 W/m2. The stability and practicality of the system with a water-cooling energy exchange circuit were demonstrated, providing an effective strategy for the recovery and utilization of heat energy loss in the thermoelectric conversion process.

13 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYafeng Wu
Yafeng Wu
ZZZhe Zhang
Zhe Zhang
WLWenbin Li
Wenbin Li
DXDaochun Xu
Daochun Xu
A two-phase closed thermosyphon is an efficient heat transfer element. The heat transfer process of this type of thermosyphon includes conduction and convective heat transfer accompanied by phase changes. Variations in the inclination angle of a thermosyphon affect the steady-state heat transfer performance of the device. Therefore, the inclination angle is an important factor affecting the performance of a thermosyphon. In this paper, an equation for the actual heating area variations with respect to the inclination angle is deduced, and a model for the areal thermal resistance of a thermosyphon is proposed by analyzing the main influence mechanisms of the inclination angle on the heat transfer process. The experimental results show that the areal thermal resistance, which accounts for the effect of the actual heating area, does not change with respect to the inclination angle and exhibits a linear relationship with the heat transfer rate. The thermal resistance equation is fit according to the experimental data when the inclination angle of the thermosyphon is vertically oriented (90°), and the predicted values of the thermosyphon’s thermal resistance are obtained when the thermosyphon is inclined. The deviations between the experimental data and predicted values are less than ±0.05. Therefore, the theoretical equation can accurately predict the thermosyphon’s thermal resistance at different inclination angles.

20 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZZZhe Zhang
Zhe Zhang
YWYafeng Wu
Yafeng Wu
WLWenbin Li
Wenbin Li
DXDaochun Xu
Daochun Xu
For the purpose of collecting solar radiation for energy conversion and utilization and improving the output performance of thermoelectric power-generation components, a new solar thermoelectric conversion device based on an all-glass solar heat transfer pipe and gravity-assisted heat pipe with recycling air cooling and water cooling circuits is designed. The uniqueness of the device lies in the combination of gravity-assisted heat pipes with excellent thermal conductivity and a direct air-cooled mode, a fin-cooled mode, and two solar-driven water-cooling modes with different flow rates. Based on the structure, the device can realize four separate output modes and multiple composite output modes and has practical significance for meeting different load power requirements, such as wireless sensors and electronics. Under a state of regular illumination from 3.14 × 104 lx to 10.04 × 104 lx, with one thermoelectric power generator (TEG) in one mode, the peak output voltage and power values of the device in single-output mode range from 183.1 mV to 370.7 mV and 33.5 mW to 137.2 mW, respectively, proving the feasibility of the proposed device. The energy supply of the above structure is completely obtained from the natural environment, and this aspect provides a high reference value for the cross-research of natural environment energy utilization and thermoelectric energy-conversion technology.

14 July 2020 in IEEE Access
Verified
Journal Article
Open access
ZZZhe Zhang
Zhe Zhang
LGLatai Ga
Latai Ga
DXDaochun Xu
Daochun Xu
WLWenbin Li
Wenbin Li
The stable exchange of energy and the effective conduction of heat are particularly critical to ensuring the stable operation of thermoelectric components in entire thermoelectric conversion processes. Poor heat exchange and conduction will cause thermal energy in a thermoelectric system to accumulate, leading to the consequence of burning the energy conversion modules. To solve these problems, a thermoelectric energy conversion system equipped with a water-cooling thermal energy adjustment structure settled on the surface of the heat source was proposed. The working temperature of the heat source, the output voltage, current, and power of the thermoelectric system with and without the structure were obtained and compared. Through comparative analysis, benefiting from the above structure, the temperature fluctuation of the heat sink surface of the heat source was found to drop from 10.36 K to 1.18 K, and the maximum output of the system increased from 255 to 290 mV through the process of input voltage from 1 to 6 V. Furthermore, in the process of gradually increasing the load from 0 to 180 ohms, the system achieves an increased output of 53.8 mV, 1.81 mA and 52.1 mV, 1.83 mA when the input voltage was 4 and 5 V, respectively. In conclusion, the application and design of the above structure obviously promotes the stability and output capacity during thermoelectric energy conversion. The combination of the water-cooling thermal energy adjustment structure with pulse-width modulation (PWM) or maximum power point tracking (MPPT) theory is worth further study.

1 April 2021 in Energy
Verified
Journal Article
Closed access
XSXiaomei Sui
Xiaomei Sui
ZZZhe Zhang
Zhe Zhang
YZYuqi Zhang
Yuqi Zhang
DXDaochun Xu
Daochun Xu
WLWenbin Li
Wenbin Li