Lawrence Nsubuga

Prof. Dr. Lawrence Nsubuga

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Food Control
Verified
Journal Article
Closed access
NANiki Alexi
Niki Alexi
JHJeanette Hvam
Jeanette Hvam
BLBirgitte W. Lund
Birgitte W. Lund
LNLawrence Nsubuga
Lawrence Nsubuga
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen
JLJørgen Leisner
Jørgen Leisner

29 April 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
ZTZoltan-Mihály Török
Zoltan-Mihály Török
ABArthur Frederic Blaser
Arthur Frederic Blaser
KKKiana Kavianynejad
Kiana Kavianynejad
CTCarlos Gonzalo Moya Gual de Torrella
Carlos Gonzalo Moya Gual de Torrella
LNLawrence Nsubuga
Lawrence Nsubuga
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen
Extensive research shows that there is a close correlation between a disease diagnostic and the patient’s exhale breath gas composition. It has been demonstrated, for example, that patients with a diabetes diagnosis have a certain level of acetone fume in their exhale breath. Actually, symptoms from many other diseases could be easily diagnosed if appropriate and reliable gas sensing technologies are available. The COVID-19 pandemic has created demand for a cheap and quick screening tool for the disease, where breath biomarker screening could be a very promising approach. It has been shown that COVID-19 patients potentially present a simultaneous increase in ethanal (acetaldehyde) and acetone in their exhale breath. In this paper, we explore two different sensing approaches to detect ethanal/acetone, namely by colorimetric markers, which could for example be integrated into facemasks, and by a breathalyzer containing a functionalized quartz crystal microbalance. Both approaches can successfully detect the presence of a biomarker gas on a person’s breath and this could potentially revolutionize the future of healthcare in terms of non-invasive and early-stage detection of various diseases.

17 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LNLawrence Nsubuga
Lawrence Nsubuga
LDLars Duggen
Lars Duggen
TMTatiana Lisboa Marcondes
Tatiana Lisboa Marcondes
SHSimon Høegh
Simon Høegh
FLFabian Lofink
Fabian Lofink
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen
This work presents an approach for the estimation of the adsorbed mass of 1,5-diaminopentane (cadaverine) on a functionalized piezoelectrically driven microcantilever (PD-MC) sensor, using a polynomial developed from the characterization of the resonance frequency response to the known added mass. This work supplements the previous studies we carried out on the development of an electronic nose for the measurement of cadaverine in meat and fish, as a determinant of its freshness. An analytical transverse vibration analysis of a chosen microcantilever beam with given dimensions and desired resonance frequency (>10 kHz) was conducted. Since the beam is considered stepped with both geometrical and material non-uniformity, a modal solution for stepped beams, extendable to clamped-free beams of any shape and structure, is derived and used for free and forced vibration analyses of the beam. The forced vibration analysis is then used for transformation to an equivalent electrical model, to address the fact that the microcantilever is both electronically actuated and read. An analytical resonance frequency response to the mass added is obtained by adding simulated masses to the free end of the beam. Experimental verification of the resonance frequency response is carried out, by applying known masses to the microcantilever while measuring the resonance frequency response using an impedance analyzer. The obtained response is then transformed into a resonance frequency to the added mass response polynomial using a polynomial fit. The resulting polynomial is then verified for performance using different masses of cantilever functionalization solution. The functionalized cantilever is then exposed to different concentrations of cadaverine while measuring the resonance frequency and mass of cadaverine adsorbed estimated using the previously obtained polynomial. The result is that there is the possibility of using this approach to estimate the mass of cadaverine gas adsorbed on a functionalized microcantilever, but the effectiveness of this approach is highly dependent on the known masses used for the development of the response polynomial model.

13 November 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
MKMatiyas Korsa
Matiyas Korsa
Josep Maria Carmona DomingoJosep Maria Carmona Domingo
Josep Maria Carmona Domingo
LNLawrence Nsubuga
Lawrence Nsubuga
JHJeanette Hvam
Jeanette Hvam
FNFlorian Niekiel
Florian Niekiel
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen
This work demonstrates a method to optimize materials and dimensions of piezoelectric cantilevers for electronic nose applications via finite element analysis simulations. Here we studied the optimum piezoelectric cantilever configuration for detection of cadaverine, a biomarker for meat ageing, to develop a potential electronic nose for the meat industry. The optimized cantilevers were fabricated, characterized, interfaced using custom-made electronics, and tested by approaching meat pieces. The results show successful measurements of cadaverine levels for meat pieces with different ages, hence, have a great potential for applications within the meat industry shelf-life prediction.

9 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DMDaniel Mamou
Daniel Mamou
LNLawrence Nsubuga
Lawrence Nsubuga
TMTatiana Lisboa Marcondes
Tatiana Lisboa Marcondes
SHSimon Overgaard Høegh
Simon Overgaard Høegh
JHJeanette Hvam
Jeanette Hvam
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen
Micro-cantilever sensors are a known reliable tool for gas sensing in industrial applications. We have demonstrated the application of cantilever sensors on the detection of a meat freshness volatile biomarker (cadaverine), for determination of meat and fish precise expiration dates. For achieving correct target selectivity, the cantilevers need to be functionalized with a cadaverine-selective binder, based on a cyclam-derivative. Cantilever surface properties such as surface energy strongly influence the binder morphology and material clustering and, therefore, target binding. In this paper, we explore how chemical and physical surface treatments influence cantilever surface, binder morphology/clustering and binding capabilities. Sensor measurements with non-controlled surface properties are presented, followed by investigations on the binder morphology versus surface energy and cadaverine capture. We demonstrated a method for hindering binder crystallization on functionalized surfaces, leading to reproducible target capture. The results show that cantilever surface treatment is a promising method for achieving a high degree of functionalization reproducibility for industrial cantilever sensors, by controlling binder morphology and uniformity.

15 April 2024 in ACS Sensors
Verified
Journal Article
Closed access
LNLawrence Nsubuga
Lawrence Nsubuga
LDLars Duggen
Lars Duggen
FBFrank Balzer
Frank Balzer
SHSimon Høegh
Simon Høegh
TMTatiana L. Marcondes
Tatiana L. Marcondes
Roana de Oliveira HansenRoana de Oliveira Hansen
Roana de Oliveira Hansen