Abdul Majeed Muzathik

Prof. Dr. Abdul Majeed Muzathik

South Eastern University of Sri Lanka
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Energy
Verified
Journal Article
Closed access
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
MIMohd Zamri Ibrahim
Mohd Zamri Ibrahim
KSK.B. Samo
K.B. Samo
WNWAN MOHD NORSANI BIN WAN NIK
WAN MOHD NORSANI BIN WAN NIK

1 January 2012 in Solar Energy
Verified
Journal Article
Closed access
WNWAN MOHD NORSANI BIN WAN NIK
WAN MOHD NORSANI BIN WAN NIK
MIMohd Zamri Ibrahim
Mohd Zamri Ibrahim
KSK.B. Samo
K.B. Samo
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik

Verified
Journal Article
Open access
PDF file
MMMohd Azlan Musa
Mohd Azlan Musa
MRM. F. Roslan
M. F. Roslan
MAM. F. Ahmad
M. F. Ahmad
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
MMM. A. Mustapa
M. A. Mustapa
MRMohd Asamudin Rahman
Mohd Asamudin Rahman
Overtopping breakwater for energy conversion (OBREC) is integration between breakwater and wave energy converter (WEC) that allows incoming waves to be stored in the reservoir. The higher the overtopping amount collected in a reservoir, the greater the energy generated will be. Hence, most of the overtopping concept has attempted to maximize the inclusion of water in the reservoir by optimizing geometrical parameters, particularly the ramp angle. However, the studies corresponding to ramp shapes geometries have not been adequately reviewed. Most studies only focused on the usage of linear overtopping ramp shape. There is still limited knowledge on the influence of different ramp shape parameters towards the overtopping wave. Thus, this paper aimed to push the border of available knowledge by investigating the influence of the ramp shape parameters to the overtopping wave discharge through simulation and experimenting approaches. Seven different ramp shapes have been tested under Malaysia’s wave condition and a new ramp shape parameter allowing for maximized overtopping wave on OBREC is presented.

1 February 2010 in American Journal of Engineering and Applied Sciences
Verified
Journal Article
Open access
PDF file
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
Problem statement: This study examined in detail some aspects of radiation climatology for Terengganu state in Malaysia. The geographical co-ordinates of the site are 5°10’N latitude 103°06’E longitude and 5.2 m altitude. Approach: The data used in the present study were taken from a recording data station installed at site by the Malaysian Meteorology Department (2004). In addition to this, wind speed, solar radiation and air temperature data taken from University Malaysia Terengganu Renewable Energy Station were also analyzed. The averaged solar radiation year for Terengganu is generated from mid-term daily global solar radiation data. The averaged data of the daily global solar radiation for the locations considered are presented in a tabular form for a complete year. Results: The highest daily and monthly mean global solar irradiation values were 7560 and 6566 Wh m-2 day-1, respectively. The highest hourly average solar irradiance intensity was 1139 W m-2 during this study period. Yearly average daily solar energy was 18.92 MJ m-2 day-1. Besides the global solar radiation, the clearness indexes, wind speed and air temperature variation are discussed. Conclusion/Recommendations: The results in this study will fill the gap that complete and detailed reference solar radiation and climatologically data, which are not available for Terengganu state of Malaysia and will be useful to the designers of solar energy conversion and utilization devices.

1 January 2010 in Energy Research Journal
Verified
Journal Article
Open access
PDF file
MIMohd Ibrahim
Mohd Ibrahim
MIMohd Zamri Ibrahim
Mohd Zamri Ibrahim
RZRoziah Zailan
Roziah Zailan
MIMarzuki Ismail
Marzuki Ismail
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
Problem statement: The purpose of this study is to design a renewable energy hydrogen based power system to provide electricity to a coastal residential area in east coast area (Kuala Terengganu) of Malaysia. Approach: The selected case study represents a power demand of 20 kWh day-1. The autonomous system used in this study is diesel generator, wind and photovoltaic hybrid system. The power system was redesigned and optimized as hydrogen-based autonomous power systems in order to meet the existing user's power demand at a minimum cost of energy. Wind speed and solar radiations data obtained from Malaysian Meteorological Department have been used in the simulation process through optimization software, Hybrid Optimization Model for Electric Renewables (HOMER). Results: Three systems that were considered in this study area are stand alone PV-wind-diesel, stand alone PV-wind-hydrogen and grid connected PV-wind-hydrogen energy system. The proposed systems then were compared regarding on their operational characteristics and cost values. The comparisons prove that grid connected PV-wind-hydrogen energy system had the lowest total net present cost and cost of energy, $53,197 and $0.57/kWh, respectively that makes it the most cost effective system and followed by PV-wind-diesel and stand alone PV-wind-hydrogen system. Conclusion/Recommendations: It can be concluded that the hydrogen-based system can become a favorable system without aid from the grid system and bring advantage in technical and economic point of view and also suitable to be applied in the coastal residential application as energy carrier if only the current cost of wind turbine, PV arrays and hydrogen system technology have been reduced to its minimum rate.

1 June 2009 in Wind Engineering
Verified
Journal Article
Closed access
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
WNWAN MOHD NORSANI BIN WAN NIK
WAN MOHD NORSANI BIN WAN NIK
MIMohd Zamri Ibrahim
Mohd Zamri Ibrahim
KSK.B. Samo
K.B. Samo
The analysis of wind data collected from the Renewable Energy Research Center, University Malaysia Terengganu (RERC UMT) using NRG Symphonie data retriever in Kuala Terengganu between the years 2004 and 2007. The RERC UMT station is located at 4°13.6′ N and 103°26.1′ E. Wind data were recorded at a height of 18 m above the ground level. This paper presents wind characteristics of the study site in Terengganu. The daily, monthly and annual wind speed values have been studied together with their prevailing direction. The monthly average wind speed and yearly mean wind speed for Kuala Terengganu ranged from 2.0–5.2 m/s and 2.9 m/s respectively. Northeast monsoon season (November to March) mean wind speed was 3.9 m/s for the same period. The average Weibull shape parameter k and scale parameter c were 1.76 and 3.21 m/s respectively for this period. The wind power is lowest during southwest monsoon season and highest during the northeast monsoon season (mean value 84.60 W/m2). The wind energy density is lowest at 11.33 W/m2 in June 2005, highest at 154.02 W/m2 in January 2007. The monthly average wind energy density and probability of wind to exceed of electricity generation wind speed 2.5 m/s were found as 40.52 W/m2 and 0.51 based on Weibull distribution, respectively. The annual average turbulence intensities were 0.58 and no significant seasonal variation in turbulence intensity was observed. In conclusion, wind energy could be used to provide power during the northeast monsoon season at the study site, using small (kW range) wind machines.