Frank Scholzen

Frank Scholzen


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
MRMichael Rakotonjanahary
Michael Rakotonjanahary
FSFrank Scholzen
Frank Scholzen
Daniele WaldmannDaniele Waldmann
Daniele Waldmann
Modular buildings offer faster construction process, provide better construction quality, allow reducing construction waste and are potentially flexible. Frames of modular units can be made of metal, timber, concrete or mixed materials but lightweight structures do not always allow erecting high-rise buildings and generally present a higher risk of overheating and/or overcooling. To reconcile these pros and cons, a typology of modular building called Slab was designed by a group of architects. The building is composed on the one hand of a permanent concrete structure named shelf-structure and on the other hand of several flexible removable timber modular units, also known as modules. The shelf-structure will host the common utility rooms and will serve as docking infrastructure for the housing modules. To provide high flexibility, the Slab building was designed to adapt to any orientation and location in Luxembourg. An energy concept and a HVAC systems design has been developed for the Slab building. Furthermore, a two-fold sustainability analysis was carried out. The first part of the analysis regards the determination of the minimum required wall thicknesses of the modules in accordance with Luxembourgish regulatory requirements, although the current regulation does not yet consider the Slab building typology. The second part, which is the subject of this paper, is thermal comfort assessment, more precisely, summertime overheating risk assessment of these modules, in compliance with Luxembourgish standard. In this regard, dynamic thermal simulations have been realized on two module variants; the first fulfills the passive house requirements, and the second—the current requirements for building permit application, which in principle corresponds to low energy house requirements. Simulations showed that with adequate solar shading and reinforced natural ventilation by window opening, overheating risk could be avoided for the normal residential use scenario for both module variants.

1 April 2014 in Journal of Cleaner Production
Verified
Journal Article
Open access
JTJoana Tarrés
Joana Tarrés
SMStefan Maas
Stefan Maas
FSFrank Scholzen
Frank Scholzen
AZArno Zürbes
Arno Zürbes


6 June 2011 in Bauphysik
Verified
Journal Article
Closed access
PDF file
SMStefan Maas
Stefan Maas
FSFrank Scholzen
Frank Scholzen
ATAndreas Thewes
Andreas Thewes
Daniele WaldmannDaniele Waldmann
Daniele Waldmann
AZArno Zürbes
Arno Zürbes


20 September 2021 in Data in Brief
Verified
Journal Article
Open access
ASArsalan Shirani
Arsalan Shirani
AMAlexander Merzkirch
Alexander Merzkirch
JRJennifer Roesler
Jennifer Roesler
SLStephan Leyer
Stephan Leyer
FSFrank Scholzen
Frank Scholzen
SMStefan Maas
Stefan Maas
This data article presents the raw data used in the article “Experimental and analytical evaluation of exhaust air heat pumps in ventilation-based heating systems” [1]. The data set contains measurement results of a field monitoring on a residential exhaust air heat pump system (air-to-air heat pump) in Germany. This data could be used to investigate the dynamic behavior and performance of the exhaust air heat pump systems. The data set contains air temperature and humidity of all four sides of the heat pump unit. Moreover, the electrical consumption of the unit and the dynamic pressure difference on the exhaust side (as indication of the air volume rate) could be also found in the data set.