Bodo Gross

Dr. Bodo Gross


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2011 in Journal of Power Sources
Verified
Journal Article
Closed access
BGBodo Gross
Bodo Gross
LBLudger Blum
Ludger Blum
LHL.G.J. de Haart
L.G.J. de Haart
ADA. Dengel
A. Dengel

12 July 2022 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
HMHassan Mahach
Hassan Mahach
FLFatima-Ezzahra Lafqir
Fatima-Ezzahra Lafqir
BBBrahim Benhamou
Brahim Benhamou
ABAmin Bennouna
Amin Bennouna
CSChristoph Schmidt
Christoph Schmidt
HAHorst Altgeld
Horst Altgeld
This work aims at investigating the impact of an Earth-Air Heat eXchanger (EAHX) on the thermal comfort when it is added to a natural nighttime ventilation for a house located in Marrakech (Morocco), which is characterized by a hot semi-arid climate. The thermal behavior of the house associated with this cooling combination was assessed using dynamic simulations. Two transient models are used, the well-validated Type 460 model of trnsys software (Transient System Simulation) for the EAHX and a separate trnsys-based model for the building, recently validated using an onsite long-term monitoring of the house under study in the present work. Many configurations of the house ranging from the building without any passive technique to the building with envelope thermal insulation connected with the EAHX combined with natural nighttime ventilation strategy have been investigated. The results showed that the nighttime ventilation strategy alone keeps the operative temperature lower than the convenient 28 °C for 92% of the time during the cooling period. On the other hand, when the EAHX alone is used, the operative temperature is lower than 28 °C during 57% of the time during the hot season. Hence, it was concluded that the passive nighttime ventilation alone leads already to a great thermal comfort improvement; however, its combination with an additional EAHX system results in convenient temperatures lower than 28 °C for 99% of time during the complete cooling period. It is found also that by applying nighttime ventilation, the air blowing flowrate can be reduced by up to three air change per hour while keeping the same EAHX’ parameters.

15 October 2018 in Chemical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
DKDaniel Kronenberger
Daniel Kronenberger
BGBodo Gross
Bodo Gross


27 May 2015 in Zeitschrift für Energiewirtschaft
Verified
Journal Article
Closed access
PDF file
AZAlexander Zipp
Alexander Zipp
BGBodo Gross
Bodo Gross