Sharin Ab Ghani

Mr. Sharin Ab Ghani


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2011 in Talanta
Verified
Journal Article
Closed access
IIILLYAS MD ISA
ILLYAS MD ISA
SMS. Mustafar
S. Mustafar
MAM. Ahmad
M. Ahmad
NHN. Hashim
N. Hashim
SGSharin Ab Ghani
Sharin Ab Ghani

1 January 2021 in International Journal of Environmental Science and Development
Verified
Journal Article
Open access
ADAMIR ABDULLAH MUHAMAD DAMANHURI
AMIR ABDULLAH MUHAMAD DAMANHURI
AHAzian Hariri
Azian Hariri
SGSharin Ab Ghani
Sharin Ab Ghani
MMMohd Syafiq Syazwan Mustafa
Mohd Syafiq Syazwan Mustafa
SHSafarudin Ghazali Herawan
Safarudin Ghazali Herawan
NPNuur Azreen Paiman
Nuur Azreen Paiman
Particulate matter and ultrafine particles are emitted during the pre-processing and post-processing activities of selective laser sintering (SLS) processes, which is major concern to operators exposed to the powders. This study aims to determine the occupational exposure (in terms of the total particle concentration and respirable particulate concentration) during the pre-processing and post-processing activities of SLS processes using virgin and recycled polyamide 12 (PA12) powders. Personal air sampling was performed for each activity according to the NIOSH 0500 and NIOSH 0600 methods. Based on the results, both powders were uniform spheres with a particle size of 40–60 μm. The total particulate concentration was most significant during the following pre-processing activities: 1) pouring powder into the mixing machine and 2) transferring the powder to the SLS AM machine. The total particulate concentration and respirable particulate concentration were slightly higher for the virgin powder for these activities. In conclusion, the virgin and recycled PA12 powders were both inhalable and respirable, which poses serious health hazards to the SLS AM operators. Hence, it is essential for operators to use suitable personal protective equipment (including respirators) and the working practices need to be improved by automating

1 February 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
ICImran Sutan Chairul
Imran Sutan Chairul
SGSharin Ab Ghani
Sharin Ab Ghani
NBNorazhar Abu Bakar
Norazhar Abu Bakar
NRNor Hidayah Rahim
Nor Hidayah Rahim
NANur Hakimah Ab Aziz
Nur Hakimah Ab Aziz
Studies show that acids influence the electrical insulation strength of transformer insulating oil. Thus, this study was conducted to verify the influence of Low Molecular Acid (LMA) and High Molecular Acid (HMA) on the breakdown voltage of transformer insulating oil. Different weight of LMA and HMA were added into transformer insulating oil samples and then mixed using hotplate magnetic stirrer at 50°C and 750 rpm for 3 hours. Prior to the mixing process, mineral insulating oil samples were filtered, dried and its moisture content were determined according to ASTM D1533 standard test condition. After the mixing process, total acid number (TAN) and AC breakdown voltage (BdV) of the oil mixtures were measured according to standard test conditions of ASTM D974 and ASTM D1816 respectively. The obtained results verified that LMA significantly reduced the breakdown voltage of mineral insulating oil compared to HMA for acidity lower than 1 mg KOH/g.

1 March 2023 in IAES International Journal of Artificial Intelligence (IJ-AI)
Verified
Journal Article
Open access
PDF file
NBNorazhar Abu Bakar
Norazhar Abu Bakar
ICImran Sutan Chairul
Imran Sutan Chairul
SGSharin Ab Ghani
Sharin Ab Ghani
MKMohd Shahril Ahmad Khiar
Mohd Shahril Ahmad Khiar
MWMohd Zamri Che Wanik
Mohd Zamri Che Wanik
Dissolved gas analysis (DGA) is widely accepted as an effective method to detect incipient faults within power transformers. Gases such as hydrogen, methane, acetylene, ethylene and ethane are normally utilized to identify the transformer fault conditions. Several techniques have been developed to interpret DGA results such as the key gas method, Doernenburg, Rogers, IEC ratio-based methods, Duval Triangles, and the latest Duval Pentagon methods. However, each of these approaches depends on the experts' shared knowledge and experience rather than quantitative scientific methods, therefore different diagnoses may be reported for the same oil sample. To overcome these shortcomings, this paper proposed the use of decision tree method to interpret the transformer health condition based on DGA results. The proposed decision tree model employed three main fault gases; methane, acetylene, ethylene as inputs, and classified the transformer into eight fault conditions. The J48 algorithm is used to train and developed the decision tree model. The performance of the proposed model is validated with the pre-known condition of transformers and compared with the Duval Triangle method. Results show that the proposed model delivers better precision and accuracy in predicting transformer fault conditions compared to DTM with 81% and 69% respectively.

1 May 2023 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
SGSharin Ab Ghani
Sharin Ab Ghani
MKMohd Shahril Ahmad Khiar
Mohd Shahril Ahmad Khiar
ICImran Sutan Chairul
Imran Sutan Chairul
NRNor Hidayah Rahim
Nor Hidayah Rahim
SHSyahrun Nizam Md Arshad@ Hashim
Syahrun Nizam Md Arshad@ Hashim
Studies have shown that high-voltage power transmission lines emit electromagnetic radiation, which has adverse effects on human health. This paper presents the effects of parameter adjustment on the electric and magnetic fields of an overhead power transmission line model at human height. A finite element software, COMSOL multiphysics, was used to simulate the electric and magnetic fields. The electric and magnetic fields generated by the 1200-kV and 220-kV overhead power transmission line models were first computed and the models were validated by comparing the simulation results with those of previous studies. Numbers of parameter were adjusted in order to investigate their effects on the electric and magnetic field distributions. Based on the results, the electric field intensity increases with an increase in the voltage of the conductors. The magnetic field density increases with an increase in the current carried by the conductors. A voltage of 700 kV results in an electricity field intensity that exceeds the residential safety limit (50 kV/m) set by the International Commission on Non-Ionizing Radiation Protection. Hence, a proper right-of-way is needed to ensure that residential areas are at a safe distance away from transmission towers.

1 January 2012
Verified
Conference Paper
Open access
PDF file
AAA. H. Abdullah
A. H. Abdullah
ASA. Y. Md. Shakaff
A. Y. Md. Shakaff
AAA. H. Adom
A. H. Adom
MAMuhammad Nauman Ahmad
Muhammad Nauman Ahmad
AZAmmar Zakaria
Ammar Zakaria
ISI.A. Seman
I.A. Seman