Additive manufacturing (AM) stands out as one of the promising technologies that have huge potential towards manufacturing industry. The study on additive manufacturing impact on the environment and occupational exposure are attracting growing attention recently. However, most of the researcher focus on desktop and fused deposition modelling type and less attention given to the industrial type of AM. Usually, during the selective laser sintering process, recycle powder will be used again to reduce cost and waste. This article compares the PM 2.5, carbon dioxide (CO2) and total volatile organic compound (TVOC) concentration between virgin and recycles powder using polyamide-nylon (PA12) towards indoor concentration. Four phases of sampling involve during air sampling accordingly to the Industry Code of Practice on Indoor Air Quality 2010 by DOSH Malaysia. It was found that PM 2.5 and CO2concentration are mainly generated during the pre-printing process. The recycle powder tended to appear higher compared to virgin powder in terms of PM 2.5, and CO2. The peak value of PM 2.5 is 1452 µg/m3 and CO2 is 1218 ppm are obtained during the pre-printing process during 8 hours of sampling. TVOC concentration from recycling powder is slightly higher during the post- printing phase where confirm the influence of the powder cake and PA12 temperature from the printing process. In summary, this work proves that elective laser sintering (SLS) machine operators are exposed to a significant amount of exposure during the SLS printing process. Mitigation strategies and personal protective equipment are suggested to reduce occupational exposure.
18 January 2023 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
In Malaysia, students spend up to 33% of their day in classrooms and school buildings. Previous research had shown that thermal comfort conditions in educational buildings can stimulate student productivity. This study aimed to preliminary investigate the relationship between thermal sensation and student performance in the classroom. Data collection was conducted in a selected classroom at a secondary school in Segamat, Johor. All data were collected for three days. Physical measurement data were taken using thermal comfort equipment, KIMO AMI 310 for indoor measurement (air temperature, mean radiant temperature, air velocity, relative humidity), and TSI VelociCalc for outdoor measurement (air temperature, relative humidity). The thermal comfort satisfaction questionnaire was distributed to 36 students in the classroom. The learning performance was assessed through a simple reaction test and digit span test based on the WHO Neurobehavioral Core Test Battery (NCTB) method. The results of the thermal comfort satisfaction questionnaire clearly showed that the lower the fan speed, the more students preferred the cooler option. Furthermore, students performed better when the fan speed was increased. Based on the correlation analysis, it can be concluded that the learning performance and thermal preference vote (TPV) are positively correlated. As a result, students tend to get higher scores when they feel cooler. This study provides important preliminary information on classroom conditions in secondary schools in Malaysia and provides a better understanding of the relationship between thermal perception and student learning performance in the classroom.
1 January 2021 in International Journal of Environmental Science and Development
Particulate matter and ultrafine particles are emitted during the pre-processing and post-processing activities of selective laser sintering (SLS) processes, which is major concern to operators exposed to the powders. This study aims to determine the occupational exposure (in terms of the total particle concentration and respirable particulate concentration) during the pre-processing and post-processing activities of SLS processes using virgin and recycled polyamide 12 (PA12) powders. Personal air sampling was performed for each activity according to the NIOSH 0500 and NIOSH 0600 methods. Based on the results, both powders were uniform spheres with a particle size of 40–60 μm. The total particulate concentration was most significant during the following pre-processing activities: 1) pouring powder into the mixing machine and 2) transferring the powder to the SLS AM machine. The total particulate concentration and respirable particulate concentration were slightly higher for the virgin powder for these activities. In conclusion, the virgin and recycled PA12 powders were both inhalable and respirable, which poses serious health hazards to the SLS AM operators. Hence, it is essential for operators to use suitable personal protective equipment (including respirators) and the working practices need to be improved by automating
This paper explores the electrical conductivity interphase of Ag/Epoxy composite using modified McLachlan theory and 3D finite element composite model through experimental verification. The model characteristic presents conductivity as a dynamic function influenced by particle content, particle electrical properties, electrical properties transition, and an exponent. This model was meticulously crafted, considering the intricate interplay between the polymer matrix and silver particles, the tunnelling distance between adjacent silver particles, and the interphase regions around particles. This model has proven its mettle through rigorous analysis of experimental results and the impact of various parameters on conductivity. The predictions have shown impressive alignment with the experimental data, highlighting the crucial roles played by the parameters in the conductivity of silver composites where the percolation threshold reached 6 vol % of filler loading. The experimental study demonstrated that the electrical conductivity was 3.84 × 10−1 S/cm for micro-sized particles and 1.32 × 10−2 S/cm for nano-sized particles. Notably, a large tunnelling distance drastically reduces conductivity, while higher and slighter surface energies of the polymer matrix and filler enhance conductivity. Furthermore, a thin interphase yields minimal conductivity, whereas a thick interphase and low waviness improve conductivity. The McLachlan-modified model falls slightly short in accuracy compared to the 3D finite element method models. Adjustments to the equations can enhance its alignment with experimental data.
Currently, fiberglass is used as an insulation material, and this synthetic fiber is categorised as non-biodegradable and causes air pollution. This study compa
21 September 2024 in Journal of Advanced Research in Applied Sciences and Engineering Technology
This study assesses Sick Building Syndrome (SBS) symptoms and Indoor Air Quality (IAQ) parameters among hospital ward staff. Utilizing a thorough methodology, a questionnaire survey and IAQ monitoring were conducted, aligning with Department of Occupational Safety and Health (DOSH) guidelines. IAQ parameters are generally within limits, except for relative humidity which recorded values of 73.09-75.23% for Ward 16 and 62.33-71.13% for Ward 18. Respondents expressed concerns about room conditions, including temperature variations, unpleasant odours, and noise. Fatigue, difficulties concentrating, and various respiratory symptoms were prevalent, suggesting potential health issues linked to indoor pollutants. The findings underscore the urgency of addressing IAQ concerns to improve the well-being of patients and healthcare workers.