OBJECTIVES: Right heart failure (RHF) after the implantation of a left ventricular assist device (LVAD) remains a dreaded postoperative complication. Using 2D speckle-tracking echocardiography, it is possible to acquire right ventricular global and regional function. The aim of our study was to assess whether speckle-tracking echocardiography values will better predict the RHF post-continuous-flow LVAD implantation. METHODS: From January 2014 to January 2016, 54 patients who underwent LVAD implantation were included and retrospectively analysed. Clinical, invasive haemodynamic (right and left heart catheterization), laboratory and transthoracic echocardiography data were reviewed. Multivariable logistic regression was performed using RHF as dependent variable. RESULTS: Thirteen patients (24%) developed RHF. These patients had significantly elevated procalcitonin (P =0.011), elevated central venous pressure (CVP) pre- and post-LVAD implantation (P =0.002 and 0.031, respectively), higher right ventricular (RV) and pulmonary systolic pressure (P =0.016 and 0.013, respectively), higher Michigan Risk Score (P =0.001) and a lower peak systolic longitudinal strain of the basal RV free wall (P =0.032). Haemoglobin, procalcitonin, RV systolic pressure, basal right ventricular free wall and pre-CVP entered the final multivariable analysis, only basal right ventricular free wall (P <0.001) and pre-CVP (P <0.001) remained significant predictors of RHF. The sensitivity and specificity of the final model were 85.7% and 95.4%, respectively. The negative predictive value reached 94%. CONCLUSIONS: 2D strain parameters of the RV free wall seem to be auspicious for RV function and predicting RHF. Moreover, intraoperative CVP should not be neglected since elevated values proved to be highly associated with RHF. Our results represent a valuable supplement to other scores by considering both echocardiography and intraoperative data.
The role of extracorporeal membrane oxygenation (ECMO) in the management of critically ill COVID‐19 patients remains unclear. Our study aims to analyze the outcomes and risk factors from patients treated with ECMO. This retrospective, single‐center study includes 17 COVID‐19 patients treated with ECMO. Univariate and multivariate parametric survival regression identified predictors of survival. Nine patients (53%) were successfully weaned from ECMO and discharged. The incidence of in‐hospital mortality was 47%. In a univariate analysis, only four out of 83 pre‐ECMO variables were significantly different; IL‐6, PCT, and NT‐proBNP were significantly higher in non‐survivors than in survivors. The Respiratory Extracorporeal Membrane Oxygenation Survival Prediction (RESP) score was significantly higher in survivors. After a multivariate parametric survival regression, IL‐6, NT‐proBNP and RESP scores remained significant independent predictors, with hazard ratios (HR) of 1.069 [95%‐CI: 0.986‐1.160], P = .016 1.001 [95%‐CI: 1.000‐1.001], P = .012; and .843 [95%‐CI: 0.564‐1.260], P = .040, respectively. A prediction model comprising IL‐6, NT‐proBNP, and RESP score showed an area under the curve (AUC) of 0.87, with a sensitivity of 87.5% and 77.8% specificity compared to an AUC of 0.79 for the RESP score alone. The present study suggests that ECMO is a potentially lifesaving treatment for selected critically ill COVID‐19 patients. Considering IL‐6 and NT‐pro‐BNP, in addition to the RESP score, may enhance outcome predictions.
1 February 2019 in The Journal of Thoracic and Cardiovascular Surgery
Background: Bedside non-invasive techniques, such as radial artery tonometry, to estimate hemodynamic parameters have gained increased relevance as an attractive alternative and efficient method to measure hemodynamics in outpatient departments. For our pilot study, we sought to compare cardiac output (CO), and stroke volume (SV) estimated from a radial artery tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Gyeonggi-do, South Korea) to pulsed-wave Doppler (PWD) echocardiography derived parameters.Methods: From January 2015 to December 2016, all patients scheduled for coronary artery bypass (CABG) surgery at our department were screened. Exclusion criteria were, inter alia, moderate to severe aortic- or Mitral valve disease and peripheral arterial disease (PAD) > stage II. One hundred and seven patients were included (mean age 66.1 ± 9.9, 15 females, mean BMI 27.2 ± 4.1 kg/m2). All patients had pre-operative transthoracic echocardiography (TTE). We measured the hemodynamic parameters with the BPPA from the radial artery, randomly before or after TTE. For the comparison between the measurement methods we used the Bland-Altman test and Pearson correlation.Results: Mean TTE-CO was 5.1 ± 0.96 L/min, and the mean BPPA-CO was 5.2 ± 0.85 L/min. The Bland-Altman analysis for CO revealed a bias of −0.13 L/min and SD of 0.90 L/min with upper and lower limits of agreement of −1.91 and +1.64 L/min. The correlation of CO measurements between DMP-life and TTE was poor (r = 0.501,p < 0.0001). The mean TTE-SV was 71.3 ± 16.2 mL and the mean BPPA-SV was 73.8 ± 19.2 mL. SV measurements correlated very well between the two methods (r = 0.900,p < 0.0001). The Bland-Altman analysis for SV revealed a bias of −2.54 mL and SD of ±8.42 mL and upper and lower limits of agreement of −19.05 and +13.96 mL, respectively.Conclusion: Our study shows for the first time that the DMP-life tonometry device measures SV and CO with reasonable accuracy and precision of agreement compared with TTE in preoperative cardiothoracic surgery patients. Tonometry BPPA are relatively quick and simple measuring devices, which facilitate the collection of cardiac and hemodynamic information. Further studies with a larger number of patients and with repeated measurements are in progress to test the reliability and repeatability of DMP-Life system.
1 January 2019 in Annals of Thoracic and Cardiovascular Surgery
Purpose: Timing and ideal reconstructive approach in deep sternal wound infection (DSWI) and mediastinitis still remain controversially debated. We present our own combined surgical strategy of bilateral pectoralis major muscle flap (BPMMF) or omental flap (OF) transposition.Methods: Between July 2010 and July 2016, poststernotomy patients with DSWI and mediastinitis underwent a secondary wound closure with modified BPMMF (Group A, center for disease control class (CDC)-II, n = 21; Group B, CDC-III, n = 20) or with OF (Group C, CDC-III, n = 19) following vacuum-assisted closure (VAC).Results: Significant risk factors for mediastinitis (CDC-III) were chronic obstructive pulmonary disease (COPD; p = 0.001), peripheral arterial disease (PAD; p = 0.012), cardiopulmonary bypass (CPB) time (p = 0.027), total operation time (p = 0.039), total intensive care unit (ICU) stay (p = 0.011), and blood transfusion (p = 0.049). Mean antibiotic therapy (18.4 ± 8.8[B] vs. 36.2 ± 24.4[C] days, p = 0.026) and length of hospitalization (25.2 ± 12.1[B] vs 53.8 ± 18.5 days[C], p = 0.053) were significantly longer in group C. In-hospital death was 3/19 (15.8%) in group C versus 0 in group B (p = 0.026). Frequency of recurrent mediastinitis was equal (p = 0.92); however, complications occurred more often in group C (31.6% vs. 0%, p = 0.031). The mean follow-up time was 111 ± 62 days.Conclusion: In younger (<70 years) patients without sternal bone necrosis, the BPMMF is superior to the OF technique with relatively low recurrence and mortality risks.
8 February 2017 in Journal of Cardiothoracic Surgery
The use of left ventricular assist devices (LVADs) has gained significant importance for treatment of end-stage heart failure. Fast-track procedures are well established in cardiac surgery, whereas knowledge of their benefits after LVAD implantation is sparse. We hypothesized that ultra-fast-track anesthesia (UFTA) with in-theater extubation or at a maximum of 4 h. after surgery is feasible in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level 3 and 4 patients and might prevent postoperative complications. From March, 2010 to March, 2012, 53 LVADs (50 Heart Mate II and 3 Heart Ware) were implanted in patients in our department. UFTA was successfully performed (LVAD ultra ) in 13 patients. After propensity score matching, we compared the LVAD ultra group with a matched group (LVAD match ) receiving conventional anesthesia management. Patients in the LVAD ultra group had significantly lower incidences of pneumonia (p = 0.031), delirium (p = 0.031) and right ventricular failure (RVF) (p = 0.031). They showed a significantly higher cardiac index in the first 12 h. (p = 0.017); a significantly lower central venous pressure during the first 24 h. postoperatively (p = 0.005) and a significantly shorter intensive care unit (ICU) stay (p = 0.016). Kaplan-Meier analysis after four years of follow-up showed no significant difference in survival. In this pilot study, we demonstrated the feasibility of ultra-fast-track anesthesia in LVAD implantation in selected patients with INTERMACS level 3–4. Patients had a lower incidence of postoperative complications, better hemodynamic performance, shorter length of ICU stay and lower incidence of RVF after UFTA. Prospective randomized investigations should examine the preservation of right ventricular function in larger numbers and identify appropriate selection criteria.