Tim Nagel

Dr. Tim Nagel


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2019 in Water
Verified
Journal Article
Open access
PDF file
AMAntoine MATHIEU
Antoine MATHIEU
JCjulien chauchat
julien chauchat
CBCyrille Bonamy
Cyrille Bonamy
TNTim Nagel
Tim Nagel
This paper presents a numerical investigation of the scour phenomenon around a submarine pipeline. The numerical simulations are performed using SedFoam, a two-phase flow model for sediment transport implemented in the open source Computational Fluid Dynamics (CFD) toolbox OpenFOAM. The paper focuses on the sensitivity of the granular stress model and the turbulence model with respect to the predictive capability of the two-phase flow model. The quality of the simulation results is estimated using a statistical estimator: the Brier Skill Score. The numerical results show no sensitivity to the granular stress model. However, the results strongly depend on the choice of the turbulence model, especially through the different implementations of the cross-diffusion term in the dissipation equation between the k − ε and the k − ω 2006 models. The influence of the cross-diffusion term tends to indicate that the sediment transport layer behaves more as a shear layer than as a boundary layer, for which the k − ε model is more suitable.

12 January 2023 in Boundary-Layer Meteorology
Verified
Journal Article
Closed access
PDF file
TNTim Nagel
Tim Nagel
RSRobert Schoetter
Robert Schoetter
VBVictor Bourgin
Victor Bourgin
VMValéry Masson
Valéry Masson
EOEmma Onofri
Emma Onofri

28 March 2022 in Boundary-Layer Meteorology
Verified
Journal Article
Closed access
PDF file
TNTim Nagel
Tim Nagel
RSRobert Schoetter
Robert Schoetter
VMValéry Masson
Valéry Masson
CLChristine Lac
Christine Lac
BCBertrand Carissimo
Bertrand Carissimo

21 May 2025
Verified
Conference Paper
Open access
TNTim Nagel
Tim Nagel
ALAude Lemonsu
Aude Lemonsu
VMValéry Masson
Valéry Masson
MGMarine Goret
Marine Goret
GRGreg Roberts
Greg Roberts
GDGuillaume Dumas
Guillaume Dumas
Greening cities is one solution that local authorities are using in order to reduce residents' exposure to heat, which is a major public health issue for urban populations. Urban green spaces, known to be cool spots, are an integral part of local adaptation strategies. For example, Paris' 2024-2030 Climate Plan aims to create 300 ha of additional green space by 2050. Detailed knowledge of green spaces cooling potential and variability factors likely to influence it is needed to plan effective adaptation strategies. This is one of the aims of the PANAME measurement campaign in which an experimental set-up combining in situ surface measurements and vertical profiling of the surface layer using quadcopter drones and soundings has been deployed to measure meteorological variables in five contrasting parisian green spaces and their surrounding built-up areas along summer 2023.The night-time near-surface cooling capacity of the green spaces relative to their surrounding built-up area has been calculated for different nocturnal vertical turbulent mixing in the urban canopy layer. For nights of low turbulent mixing, often associated with the highest daily temperatures, urban parks cool by several degrees compared with built-up areas, with differences depending on their size and vegetation. A small wooded garden square has a greater cooling capacity than a large grassy esplanade, illustrating the importance of tree cover, even for parks of less than 1 ha, in adapting cities.For low turbulent mixing nights, the park cooling also often extends vertically over several tens of meters, where a local inversion is found. This stable park layer is not vertically constrained by the buildings surrounding the green space as it can possibly extend higher. It is also only little influenced by the green space size as it is found similarly above urban park of 15ha and garden square of less than 1ha.

16 August 2024
Verified
Conference Paper
Open access
TNTim Nagel
Tim Nagel
MRMargaux Rivollet
Margaux Rivollet
WSWallois Sarah
Wallois Sarah
MGMarine Goret
Marine Goret
GRGreg Roberts
Greg Roberts
JDJean-Charles Dupont
Jean-Charles Dupont
Urban green infrastructures can regulate microclimate and mitigate urban heat island (UHI) effects. In summer, urban parks offer cooler spots where citizens are protected from the heat of the city, more particularly in the evening and the night, when the UHI arises. During heatwaves, urban parks can therefore play a key role in addressing health risks. Previous research shows that urban vegetation has the potential to mitigate temperatures at the pedestrian level depending on park size, vegetation type, topography or local climate. However, little is known concerning the impact of meteorological conditions (wind, turbulence, cloudiness, UHI intensity, atmospheric stability) on the urban park cooling effect. The cooling along the vertical dimension remains also sparsely quantified. One of the aims of the PANAME (for PAris region urbaN Atmospheric observations and models for Multidisciplinary rEsearch) intensive measurement campaign is to better understand and quantify the role of urban parks in regulating the microclimate during summer periods. The July 2023 special observation period (SOP) focused more particularly on investigating the horizontal and vertical cooling potential of four urban parks and woods of various sizes from late afternoon to early part of the night. The experimental set-up combined in situ surface measurements in parks and urban areas, such as profiling of the surface layer using quadcopter drones and soundings. For drone measurements, each urban park was associated with a nearby urban site, consisting in semi-enclosed to enclosed paved courtyards surrounded by buildings. Profiles were simultaneously undertaken in both urban/park environments from 16 to 20 UTC for each of the 21 days of measurements that took place for the 2023 SOP. This resulted in an innovative multi-source dataset currently being used to quantify and analyse the differences in surface and near-surface atmospheric cooling rates between an urban park and the nearby urban environment, as well as between different parks, but also to study the cooling potential related to meteorological conditions.The first results show that the evening cooling is highly dependent on the meteorological conditions, which is in agreement with recent work establishing a link between park cooling efficiencies and weather types with contrasting UHI regimes. For some evenings, the surface park cooling between the late afternoon and the sunset can reach more than 3 K while it is often less than 1 K in the urban environment. For other meteorological conditions, the cooling rate is similar between park and urban environments. When the cooling is different between parks and urban environments, the park cooling extends vertically over several tens of meters, where a local inversion is found. For those types of meteorological conditions, significant cooling is also found in very small urban parks (less than 1 ha).

27 March 2022
Verified
Conference Paper
Open access
TNTim Nagel
Tim Nagel
RSRobert Schoetter
Robert Schoetter
VBVictor Bourgin
Victor Bourgin
VMValéry Masson
Valéry Masson
EOEmma Onofri
Emma Onofri
To prepare future urban climate modelling and numerical weather prediction at the hectometer scale in cities with heterogeneous morphology and high-rise buildings, urban climate models have to be coupled at multiple levels with atmospheric models. Vertical profiles of the building drag coefficient and the urban mixing length need to be specified to parametrize the effect of the buildings on the flow. Building-resolving micro-scale simulations can be employed to derive these quantities.In the present contribution, micro-scale large-eddy simulations of eleven Local Climate Zone (LCZ) based urban morphologies with various building plan and frontal density are used to provide velocity, sectional drag coefficient and mixing length reference vertical profiles for the urban environment. The micro-scale simulations, which are of 1-m resolution in both horizontal and vertical directions, are performed with the MesoNH meteorological research model. This model represents explicitly the obstacles with the Immersed Boundary Method and accounts for the impact of the large-scale turbulence structures on the urban canopy thanks to dynamical downscaling and embedded numerical domains using the grid nesting method. The micro-scale results show that, contrary to traditional assumptions, the velocity profile is generally not exponential and the mixing length is not constant in the urban canopy. This is in agreement with more recent research. The results also show that the building frontal density seems to be a key parameter for the shape of the velocity profile, within and directly above the urban canopy.The sectional drag and mixing length profiles are then used to propose a new LCZ-based parametrization for the wind dynamics in the urban environment when using the Meso-NH model at the hectometer scale. The results show that the proposed parametrization is more efficient than the current one, consisting in a constant drag coefficient and no specific modification of the turbulent mixing length scale in the urban environment. These results open new perspectives to better parametrize the dynamic effects of real urban areas at the hectometer scale.