Mark Mckinnon

Mr. Mark Mckinnon


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Polymer Degradation and Stability
Verified
Journal Article
Closed access
YDYan Ding
Yan Ding
MMMark Mckinnon
Mark Mckinnon
SSStanislav I. Stoliarov
Stanislav I. Stoliarov
Gaelle FontaineGaelle Fontaine
Gaelle Fontaine
SBSerge Bourbigot
Serge Bourbigot

1 November 2013 in Combustion and Flame
Verified
Journal Article
Closed access
MMMark Mckinnon
Mark Mckinnon
SSStanislav I. Stoliarov
Stanislav I. Stoliarov
AWArtur Witkowski
Artur Witkowski

21 November 2016 in Journal of Fire Sciences
Verified
Journal Article
Closed access
MMMark Mckinnon
Mark Mckinnon
YDYan Ding
Yan Ding
SSStanislav I. Stoliarov
Stanislav I. Stoliarov
SCSean Crowley
Sean Crowley
RLRichard E Lyon
Richard E Lyon
Carbon fiber laminate composites have been utilized in the aerospace industry by replacing lightweight aluminum alloy components in the design of aircraft. By replacing low flammability aluminum components by carbon fiber laminates, the potential fuel load for aircraft fires may be increased significantly. A pyrolysis model has been developed for a Toray Co. carbon fiber laminate composite. Development of this model is intended to improve the understanding of the fire response and flammability characteristics of the composite, which complies with Boeing Material Specification 8–276. The work presented here details a methodology used to characterize the composite. The mean error between the predicted curves and the mean experimental mass loss rate curves collected in bench-scale gasification tests was calculated as approximately 17% on average for heat fluxes ranging from 40 to 80 kW m−2. During construction of the model, additional complicating phenomena were investigated. It was shown that the thermal conductivity in the plane of the composite was approximately 15 times larger than the in-depth thermal conductivity, the mass transport was inhibited due to the high density of the laminae in the composite, and oxidation did not appear to significantly affect pyrolysis at heat fluxes up to 60 kW m−2.

14 September 2015 in Materials
Verified
Journal Article
Open access
PDF file
MMMark Mckinnon
Mark Mckinnon
SSStanislav I. Stoliarov
Stanislav I. Stoliarov
Comprehensive pyrolysis models that are integral to computational fire codes have improved significantly over the past decade as the demand for improved predictive capabilities has increased. High fidelity pyrolysis models may improve the design of engineered materials for better fire response, the design of the built environment, and may be used in forensic investigations of fire events. A major limitation to widespread use of comprehensive pyrolysis models is the large number of parameters required to fully define a material and the lack of effective methodologies for measurement of these parameters, especially for complex materials. The work presented here details a methodology used to characterize the pyrolysis of a low-pile carpet tile, an engineered composite material that is common in commercial and institutional occupancies. The studied material includes three distinct layers of varying composition and physical structure. The methodology utilized a comprehensive pyrolysis model (ThermaKin) to conduct inverse analyses on data collected through several experimental techniques. Each layer of the composite was individually parameterized to identify its contribution to the overall response of the composite. The set of properties measured to define the carpet composite were validated against mass loss rate curves collected at conditions outside the range of calibration conditions to demonstrate the predictive capabilities of the model. The mean error between the predicted curve and the mean experimental mass loss rate curve was calculated as approximately 20% on average for heat fluxes ranging from 30 to 70 kW·m−2, which is within the mean experimental uncertainty.

2 March 2023 in Fire Safety Journal
Verified
Journal Article
Open access
GBGrayson T. Bellamy
Grayson T. Bellamy
MDMatthew DiDomizio
Matthew DiDomizio
MPMalhar K. Patel
Malhar K. Patel
MMMark Mckinnon
Mark Mckinnon

28 July 2020
Verified
Report
Closed access
UIUL Firefighter Safety Research Institute
UL Firefighter Safety Research Institute
MMMark Mckinnon
Mark Mckinnon
SDSean DeCrane
Sean DeCrane
SKSteve Kerber
Steve Kerber
On April 19, 2019, one male career Fire Captain, one male career Fire Engineer, and two male career Firefighters received serious injuries as a result of cascading thermal runaway within a 2.16 MWh lithium-ion battery energy storage system (ESS) that led to a deflagration event. The smoke detector in the ESS signaled an alarm condition at approximately 16:55 hours and discharged a total flooding clean agent suppressant (Novec 1230). The injured firefighters were members of a hazardous materials (HAZMAT) team that arrived on the scene at approximately 18:28 hours. The HAZMAT team noted low-lying white clouds of a gas/vapor mixture issuing from the structure and nearby components and drifting through the desert. The team defined a hot zone and made several entries into the hot zone to conduct 360-degree size-ups around the ESS using multi-gas meters, colorimetric tubes, and thermal imaging cameras (TICs). The team detected dangerously elevated levels of hydrogen cyanide (HCN) and carbon monoxide (CO) during each entry. The team continued to monitor the ESS and noted the white gas/vapor mixture stopped flowing out of the container at approximately 19:50 hours. The HAZMAT leadership developed an incident action plan with input from a group of senior fire officers and information about the ESS provided by representatives from the companies that owned, designed, and maintained the ESS. The HAZMAT team made a final entry into the hot zone and found that HCN and CO concentrations in the vicinity of the ESS were below an acceptable threshold. In following with the incident action plan, the team opened the door to the ESS at approximately 20:01 hours. A deflagration event was observed by the firefighters outside the hot zone at approximately 20:04 hours. All HAZMAT team members received serious injuries in the deflagration and were quickly transported to nearby hospitals. Note: The lithium-ion battery ESS involved in this incident was commissioned prior to release of a first draft of the current consensus standard on ESS installations, NFPA 855 [1]; the design of the ESS complied with the pertinent codes and standards active at the time of its commissioning.