Lingyun Wang

Prof. Lingyun Wang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
ZXZhenjin Xu
Zhenjin Xu
DWDezhi Wu
Dezhi Wu
ZCZhiwen Chen
Zhiwen Chen
ZWZhongbao Wang
Zhongbao Wang
CCCong Cao
Cong Cao
DSDaoheng Sun
Daoheng Sun
The tactile pressure sensor is of great significance in flexible electronics, but sensitivity customization over the required working range with high linearity still remains a critical challenge. Despite numerous efforts to achieve high sensitivity and a wide working range, most sensitive microstructures tend to be obtained only by inverting naturally existing templates without rational design based on fundamental contact principles or models for piezoresistive pressure sensors. Here, a positive design strategy with a hyperelastic model and a Hertzian contact model for comparison was proposed to develop a flexible pressure sensor with highly customizable linear sensitivity and linearity, in which the microstructure distribution was precalculated according to the desired requirement prior to fabrication. As a proof of concept, three flexible pressure sensors exhibited sensitivities of 0.7, 1.0, and 1.3 kPa−1 over a linear region of up to 200 kPa, with a low sensitivity error (<5%) and high linearity (~0.99), as expected. Based on the superior electromechanical performance of these sensors, potential applications in physiological signal recognition are demonstrated as well, and such a strategy could shed more light on demand-oriented scenarios, including designable working ranges and linear sensitivity for next-generation wearable devices.

26 August 2016 in Physical Review D
Verified
Journal Article
Open access
PDF file
ZFZiwen Fu
Ziwen Fu
LWLingyun Wang
Lingyun Wang
We deliver a lattice study of ρ resonance parameters with p-wave ππ scattering phases, which are extracted by finite-size methods at one center-of-mass frame and four moving frames for six lattice ensembles from the MILC Collaboration with pion masses ranging from 346 to 176 MeV. The effective range formula is applied to describe the scattering phases as a function of the energy covering the resonance region; this allows us to extract ρ resonance parameters and to investigate the quark-mass dependence. Lattice studies with three flavors of Asqtad-improved staggered fermions enable us to use the moving-wall source technique on large lattice spatial dimensions (L=64) and small light u/d quarks. Numerical computations are carried out at two lattice spacings, a≈0.12 and 0.09 fm.

13 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
DWDezhi Wu
Dezhi Wu
QPQianqian Peng
Qianqian Peng
SWShan Wu
Shan Wu
GWGuangshun Wang
Guangshun Wang
LDLei Deng
Lei Deng
LLLiwei Lin
Liwei Lin
Ammonia gas sensors are very essential in many industries and everyday life. However, their complicated fabrication process, severe environmental fabrication requirements and desorption of residual ammonia molecules result in high cost and hinder their market acceptance. Here, laser direct writing is used to fabricate three parallel porous 3D graphene lines on a polyimide (PI) tape to simply construct an ammonia gas sensor. The middle one works as an ammonia sensing element and the other two on both sides work as heaters to improve the desorption performance of the sensing element to ammonia gas molecules. The graphene lines were characterized by scanning electron microscopy and Raman spectroscopy. The response and recovery time of the sensor without heating are 214 s and 222 s with a sensitivity of 0.087% ppm−1 for sensing 75 ppm ammonia gas, respectively. The experimental results prove that under the optimized heating temperature of about 70 °C the heaters successfully help implement complete desorption of residual NH3 showing a good sensitivity and cyclic stability.

9 July 2013 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
LWLingyun Wang
Lingyun Wang
XDXiaohui Du
Xiaohui Du
YLYipan Li
Yipan Li
ZLZhiwei Luo
Zhiwei Luo
Gaofeng ZhengGaofeng Zheng
Gaofeng Zheng
DSDaoheng Sun
Daoheng Sun
In this paper, fundamental equations for jetting dispenser are presented to express the influence of adhesive pressure, nozzle diameter, and needle movement law, and the equations are then verified by flow behavior simulation. Subsequently, a novel jetting dispenser system is built to finish experiments about the mentioned influence parameters, and simulation results verify the regularities from experiment are correct. Flow velocity in the central nozzle will be faster and radius of the droplet will be bigger if the pressure in the chamber became higher, flow velocity in the central nozzle will be constant and the radius of the droplet will be bigger if the dead time became longer, and bigger nozzle diameter can lead to faster flow velocity in the central nozzle and bigger droplet. Besides, these mentioned works prove that our designed jetting dispenser is practical and useful for adhesive jetting.

6 April 2016 in Sensors
Verified
Journal Article
Open access
PDF file
YXYu Xie
Yu Xie
YZYunlei Zhou
Yunlei Zhou
YLYuzi Lin
Yuzi Lin
LWLingyun Wang
Lingyun Wang
WXWenming Xi
Wenming Xi
Robot-assisted cell microinjection, which is precise and can enable a high throughput, is attracting interest from researchers. Conventional probe-type cell microforce sensors have some real-time injection force measurement limitations, which prevent their integration in a cell microinjection robot. In this paper, a novel supported-beam based cell micro-force sensor with a piezoelectric polyvinylidine fluoride film used as the sensing element is described, which was designed to solve the real-time force-sensing problem during a robotic microinjection manipulation, and theoretical mechanical and electrical models of the sensor function are derived. Furthermore, an array based cell-holding device with a trapezoidal microstructure is micro-fabricated, which serves to improve the force sensing speed and cell manipulation rates. Tests confirmed that the sensor showed good repeatability and a linearity of 1.82%. Finally, robot-assisted zebrafish embryo microinjection experiments were conducted. These results demonstrated the effectiveness of the sensor working with the robotic cell manipulation system. Moreover, the sensing structure, theoretical model, and fabrication method established in this study are not scale dependent. Smaller cells, e.g., mouse oocytes, could also be manipulated with this approach.

25 August 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
ZJZhou Junqiang
Zhou Junqiang
UAUMEKO AOMURA
UMEKO AOMURA
JMJia Miao
Jia Miao
JMJingsong Mao
Jingsong Mao
LWLingyun Wang
Lingyun Wang
YZYang Zhao
Yang Zhao
Transcatheter arterial chemoembolization (TACE) is the common choice of non-open surgery for hepatocellular carcinoma (HCC) now. In this study, a simple TACE robotic system of 4-degree-of-freedom is proposed to get higher accuracy and stability of the surgery operation and reduce X-ray exposure time of the surgeons. The master–slave control strategy is adopted in the robotic system and a customized sigmoid function is designed to optimize the joystick control of the master–slave robotic control system. A force-sensing module is developed to sense the resistance of the guide wire in linear delivery motion and an auxiliary bending feedback method based on constraint pipe with a film sensor is proposed. With two force-sensing methods, the safety strategy of robotic motion with 9 different motion constraint coefficients is given and a human–computer interface is developed. The TACE robot would monitor the value of the force sensor and the analog voltage of the film sensor to adopt the corresponding motion constraint coefficient in every 10 ms. Vascular model experiments were performed to validate the robotic system, and the results showed that the safety strategy could improve the reliability of the operation with immediate speed constraint and avoid potential aggressive delivery.