Andrea Bettinelli

Dr. Andrea Bettinelli

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Radiology
Verified
Journal Article
Closed access
PWPhilip Whybra
Philip Whybra
AZAlex Zwanenburg
Alex Zwanenburg
VAVincent Andrearczyk
Vincent Andrearczyk
RSRoger Schaer
Roger Schaer
AAAditya P. Apte
Aditya P. Apte
ADAdrien Depeursinge
Adrien Depeursinge
Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.

1 June 2022 in Radiology
Verified
Journal Article
Closed access
ABAndrea Bettinelli
Andrea Bettinelli
FMFrancesca Marturano
Francesca Marturano
MAMichele Avanzo
Michele Avanzo
ELEmiliano Loi
Emiliano Loi
EMEnrico Menghi
Enrico Menghi
MPMarta Paiusco
Marta Paiusco
A novel approach was used to assess radiomic software agreement based on Italian multicenter Shared Understanding of Radiomic Extractors phantoms and a systematic feature extraction, finding that d... Background The translation of radiomic models into clinical practice is hindered by the limited reproducibility of features across software and studies. Standardization is needed to accelerate this...

12 December 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
ABAndrea Bettinelli
Andrea Bettinelli
MBMarco Branchini
Marco Branchini
FMFrancesca De Monte
Francesca De Monte
ASAlessandro Scaggion
Alessandro Scaggion
MPMarta Paiusco
Marta Paiusco

21 May 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ASAlessandro Scaggion
Alessandro Scaggion
MFMarco Fusella
Marco Fusella
GAGiancarmelo Agnello
Giancarmelo Agnello
ABAndrea Bettinelli
Andrea Bettinelli
NPNicola Pivato
Nicola Pivato
MPMarta Paiusco
Marta Paiusco
Purpose: A recently introduced commercial tool is tested to assess whether it is able to reduce the complexity of a treatment plan and improve deliverability without compromising overall quality.Methods: Ten prostate and ten oropharynx plans of previously treated patients were reoptimized using the aperture shape controller (ASC) tool recently introduced in Eclipse TPS (Varian Medical Systems, Palo Alto, CA). The performance of ASC was assessed in terms of the overall plan quality using a plan quality metric, the reduction in plan complexity through the analysis of 14 of the most common plan complexity metrics, and the change in plan deliverability through 3D dosimetric measurements. Similarly, plans optimized limiting the total number of delivered monitor units was assessed and compared. The two strategies were also combined to assess their potential combination.Results: The plans optimized by exploiting the ASC generally show a reduced number of total Monitor Units, a more constant gantry rotation and a MLC modulation characterized by larger and less complicated shapes with leaves traveling shorter overall lengths.Conclusions: This first experience suggests that the ASC is an effective tool to reduce the unnecessary complexity of a plan. This turns into an increased plan deliverability with no loss of plan quality.

30 November 2021 in Cancers
Verified
Journal Article
Open access
PDF file
PGPriscilla Guglielmo
Priscilla Guglielmo
FMFrancesca Marturano
Francesca Marturano
ABAndrea Bettinelli
Andrea Bettinelli
MGMichele Gregianin
Michele Gregianin
MPMarta Paiusco
Marta Paiusco
Laura EvangelistaLaura Evangelista
Laura Evangelista
We performed a systematic review of the literature to provide an overview of the application of PET radiomics for the prediction of the initial staging of prostate cancer (PCa), and to discuss the additional value of radiomic features over clinical data. The most relevant databases and web sources were interrogated by using the query “prostate AND radiomic* AND PET”. English-language original articles published before July 2021 were considered. A total of 28 studies were screened for eligibility and 6 of them met the inclusion criteria and were, therefore, included for further analysis. All studies were based on human patients. The average number of patients included in the studies was 72 (range 52–101), and the average number of high-order features calculated per study was 167 (range 50–480). The radiotracers used were [68Ga]Ga-PSMA-11 (in four out of six studies), [18F]DCFPyL (one out of six studies), and [11C]Choline (one out of six studies). Considering the imaging modality, three out of six studies used a PET/CT scanner and the other half a PET/MRI tomograph. Heterogeneous results were reported regarding radiomic methods (e.g., segmentation modality) and considered features. The studies reported several predictive markers including first-, second-, and high-order features, such as “kurtosis”, “grey-level uniformity”, and “HLL wavelet mean”, respectively, as well as PET-based metabolic parameters. The strengths and weaknesses of PET radiomics in this setting of disease will be largely discussed and a critical analysis of the available data will be reported. In our review, radiomic analysis proved to add useful information for lesion detection and the prediction of tumor grading of prostatic lesions, even when they were missed at visual qualitative assessment due to their small size; furthermore, PET radiomics could play a synergistic role with the mpMRI radiomic features in lesion evaluation. The most common limitations of the studies were the small sample size, retrospective design, lack of validation on external datasets, and unavailability of univocal cut-off values for the selected radiomic features.

1 March 2019 in Physica Medica
Verified
Journal Article
Closed access
MBMarco Branchini
Marco Branchini
AZAlessandra Zorz
Alessandra Zorz
PZPietro Zucchetta
Pietro Zucchetta
ABAndrea Bettinelli
Andrea Bettinelli
FMFrancesca De Monte
Francesca De Monte
MPMarta Paiusco
Marta Paiusco