A novel approach was used to assess radiomic software agreement based on Italian multicenter Shared Understanding of Radiomic Extractors phantoms and a systematic feature extraction, finding that d... Background The translation of radiomic models into clinical practice is hindered by the limited reproducibility of features across software and studies. Standardization is needed to accelerate this...
Dosiomics is a texture analysis method to produce dose features that encode the spatial 3D distribution of radiotherapy dose. Dosiomic studies, in a multicentre setting, require assessing the features’ stability to dose calculation settings and the features’ capability in distinguishing different dose distributions. Dose distributions were generated by eight Italian centres on a shared image dataset acquired on a dedicated phantom. Treatment planning protocols, in terms of planning target volume coverage and dose–volume constraints to the organs at risk, were shared among the centres to produce comparable dose distributions for measuring reproducibility/stability and sensitivity of dosiomic features. In addition, coefficient of variation (CV) was employed to evaluate the dosiomic features’ variation. We extracted 38,160 features from 30 different dose distributions from six regions of interest, grouped by four features’ families. A selected group of features (CV < 3 for the reproducibility/stability studies, CV > 1 for the sensitivity studies) were identified to support future multicentre studies, assuring both stable features when dose distributions variation is minimal and sensitive features when dose distribution variations need to be clearly identified. Dosiomic is a promising tool that could support multicentre studies, especially for predictive models, and encode the spatial and statistical characteristics of the 3D dose distribution.
Objectives: In this study, we developed a radiomic signature for the classification of benign lipid-poor adenomas, which may potentially help clinicians limit the number of unnecessary investigations in clinical practice. Indeterminate adrenal lesions of benign and malignant nature may exhibit different values of key radiomics features. Methods: Patients who had available histopathology reports and a non-contrast-enhanced CT scan were included in the study. Radiomics feature extraction was done after the adrenal lesions were contoured. The primary feature selection and prediction performance scores were calculated using the least absolute shrinkage and selection operator (LASSO). To eliminate redundancy, the best-performing features were further examined using the Pearson correlation coefficient, and new predictive models were created. Results: This investigation covered 50 lesions in 48 patients. After LASSO-based radiomics feature selection, the test dataset’s 30 iterations of logistic regression models produced an average performance of 0.72. The model with the best performance, made up of 13 radiomics features, had an AUC of 0.99 in the training phase and 1.00 in the test phase. The number of features was lowered to 5 after performing Pearson’s correlation to prevent overfitting. The final radiomic signature trained a number of machine learning classifiers, with an average AUC of 0.93. Conclusions: Including more radiomics features in the identification of adenomas may improve the accuracy of NECT and reduce the need for additional imaging procedures and clinical workup, according to this and other recent radiomics studies that have clear points of contact with current clinical practice. Clinical relevance statement: The study developed a radiomic signature using unenhanced CT scans for classifying lipid-poor adenomas, potentially reducing unnecessary investigations that scored a final accuracy of 93%. Key Points: • Radiomics has potential for differentiating lipid-poor adenomas and avoiding unnecessary further investigations.• Quadratic mean, strength, maximum 3D diameter, volume density, and area density are promising predictors for adenomas.• Radiomics models reach high performance with average AUC of 0.95 in the training phase and 0.72 in the test phase.
Prostate cancer (PCa) risk categorization based on clinical/PSA testing results in a substantial number of men being overdiagnosed with indolent, early-stage PCa. Clinically non-significant PCa is characterized as the presence of ISUP grade one, where PCa is found in no more than two prostate biopsy cores.MRI-ADC and [68Ga]Ga-PSMA-11 PET have been proposed as tools to predict ISUP grade one patients and consequently reduce overdiagnosis. In this study, Radiomics analysis is applied to MRI-ADC and [68Ga]Ga-PSMA-11 PET maps to quantify tumor characteristics and predict histology-proven ISUP grades. ICC was applied with a threshold of 0.6 to assess the features’ stability with variations in contouring. Logistic regression predictive models based on imaging features were trained on 31 lesions to differentiate ISUP grade one patients from ISUP two+ patients. The best model based on [68Ga]Ga-PSMA-11 PET returned a prediction efficiency of 95% in the training phase and 100% in the test phase whereas the best model based on MRI-ADC had an efficiency of 100% in both phases. Employing both imaging modalities, prediction efficiency was 100% in the training phase and 93% in the test phase. Although our patient cohort was small, it was possible to assess that both imaging modalities add information to the prediction models and show promising results for further investigations.
Background: This study aims to investigate stability and reproducibility of radiomics biomarkers for adrenal lesion characterization across different software packages. Methods: Unenhanced CT images from patients with adrenal tumors were analyzed. Radiomic features were extracted using SOPHIA Radiomics and SIBEX software. The datasets underwent Z-score normalization. Statistical comparisons were made using two-sample t-tests and Spearman correlation coefficients. Three classification models—Logistic Regression, Linear Discriminant Analysis, and Linear Support Vector Machine—were trained on the datasets. Model performance was evaluated using accuracy, precision, recall, F1 score, and ROC curves. Feature importance and the statistical significance of model performance differences were also analyzed. Results: The t-test results showed no significant differences in the radiomic features extracted by SOPHIA and SIBEX (p-values all equal to 1.0). Spearman correlation coefficients were high for most features, suggesting a strong similarity between the two software tools. Classification models generally performed better on the SOPHIA dataset, with higher accuracy and precision. Feature importance analysis identified “Quadratic mean” and “Strength” as consistently influential features. Paired t-tests indicated significant differences in accuracy and precision, while Wilcoxon signed-rank tests did not find significant differences across all performance metrics. Conclusions: Radiomic features extracted by SOPHIA and SIBEX are comparable, but slight variations in model performance highlight the need for standardized extraction protocols and fine-tuning of predictive features. The study underscores the importance of ensuring the stability and reproducibility of radiomics features for reliable clinical application in adrenal lesion characterization.