Based on field study data regarding the winter indoor thermal environment of three classrooms with different building envelopes, this study compared and evaluated these environments, not only related to students’ thermal comfort but also to their health. The inadequacy of the conventional New Zealand school building for maintaining a comfortable and healthy winter indoor thermal environment has been identified. A classroom with thermal mass had 31%, 34% and 9% more time than a classroom without thermal mass when indoor temperatures met 16 °C 18 °C and 20 °C respectively and has 21.4% more time than the classroom without thermal mass when indoor relative humidity was in the optimal range of 40% to 60%, in a temperate climate with a mild and humid winter. Adding thermal mass to school building envelopes should be considered as a strategy to improve the winter indoor thermal environment in future school design and development. Adding thermal mass to a school building with sufficient insulation can not only increase winter indoor mean air temperature but can also reduce the fluctuation of indoor air temperatures. This can significantly reduce the incidence of very low indoor temperature and very high indoor relative humidity, and significantly improve the indoor thermal environment.
1 January 2017 in International Journal of Chronic Obstructive Pulmonary Disease
A reduced content of alveolar elastic fibers is a key feature of COPD lung. Despite continued elastogenic potential by alveolar fibroblasts in the lung affected by COPD, repair of elastic fibers does not take place, which is due to increased levels of the chondroitin sulfate proteoglycan versican that inhibits the assembly of tropoelastin into fibers. In this study, primary pulmonary fibroblast cell lines from COPD and non-COPD patients were treated with a small interfering RNA (siRNA) against versican to determine if knockdown of versican could restore the deposition of insoluble elastin. Versican siRNA treatment reduced versican expression and secretion by pulmonary fibroblasts from both COPD and non-COPD patients (P<0.01) and significantly increased deposition of insoluble elastin in the COPD cell cultures (P<0.05). The treatment, however, did not significantly affect production of soluble elastin (tropoelastin) in either the COPD or non-COPD cell cultures, supporting a role for versican in inhibiting assembly but not synthesis of tropoelastin. These results suggest that removal or knockdown of versican may be a possible therapeutic strategy for increasing deposition of insoluble elastin and stimulating repair of elastic fibers in COPD lung.
The New Zealand Ministry of Health reported that respiratory disease affects 700,000 people, annually costs New Zealand NZ$7.05 billion, and is the third-highest cause of death. The hospitalisation rate for asthma of Māori communities is 2.0 higher than that of other ethnic groups, and hospitalisation rates for deprived homes are 2.3 times higher than those of the least deprived homes. Based on physical data and evidence, which were drawn from a mixed methodology that includes field studies of the indoor microclimate, dust-mite allergens, mould growth, and occupants’ Respiratory Health Survey of a number of sample houses of Māori communities in Minginui, Te Whaiti, Murupara, and Rotorua of New Zealand, the study identifies unhealthy indoor thermal conditions, thresholds or ranges of indoor micro-climate related to different levels of dust-mite allergen and mould growth, the most common type of indoor mould, and correlations between dust-mite and mould and correlations. The study not only identified that the poor health of occupants is closely related to their inadequate living conditions, but also identifies the threshold of indoor micro-climates to maintain indoor allergens at the acceptable level, which can be used as a guideline to maintain or improve indoor health conditions for future housing development or retrofitted old housing.
Based on field studies, this study contributes the new physical data of winter indoor thermal conditions of the indoor spaces with four different dust mite allergen levels in New Zealand houses. This study provides a new method to identify the relationships between indoor thermal conditions and indoor dust mite allergen levels. This study found that the indoor mean relative humidity (RH) close to the floor must be controlled below 70%, and there must be less than 30% of time in winter when indoor RH close to the floor is higher than or equal to 75% to maintain indoor dust mite allergens at an undetectable level; and the indoor mean RH close to the floor must be controlled below 75%, and there must be less than 50% of time in winter when indoor RH close to the floor is higher than or equal to 75% to maintain indoor dust mite allergens at a low (acceptable) level. This study also identified the relationship between indoor thermal conditions for dust mites to thrive and for mould spores to germinate. This study provides a strategy or guideline for preventing indoor allergies related to dust mites and mould under the temperate climate zone; the winter is mild and humid.
He School of Architecture at Unitec publishes an e-newsletter biannually, keeping alumni and industry contacts informed of developments in the school and its communities. The publication also provides an opportunity to share details regarding continuing professional development (CPD) opportunities for practitioners and calls for papers published in the school's peer-reviewed journals, such as XSection and Asylum. The e-newsletter, edited by Senior Lecturer Hamish Foote, supports the school in meeting the aims of its Architecture, Landscape Architecture and Interior programmes: grounding in the historical and theoretical foundations of our disciplines; knowledge of professional, social and environmental responsibilities; development of appropriate communication skills; ability to analyse work critically; and an overview of taha Māori, the Treaty of Waitangi, and Māori perspectives as they relate to our disciplines. Publication of the e-newsletter was paused during Aotearoa New Zealand’s Covid-19 outbreak, and the following items were compiled this year to share recent developments and the return to everyday life.