Renata Jadresin Milic

Dr. Renata Jadresin Milic

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
RMRenata Jadresin Milic
Renata Jadresin Milic
PMPeter McPherson
Peter McPherson
GMGraeme McConchie
Graeme McConchie
TRThomas Reutlinger
Thomas Reutlinger
SSSian Singh
Sian Singh
Over the last few decades, a significant amount of literature on the preservation and adaptive reuse of historical buildings has been published. More recently, the use of digital technologies in heritage projects and academic research has become increasingly topical worldwide. However, the topic of architectural education and the teaching of architectural history in relation to heritage is less discussed. This paper contributes to this relevant and necessary topic that has not received much attention in academia so far, and presents a case study—a real-life heritage project to teach architectural history in higher education. The methodology applied in this case study is based on the digital methods of heritage surveying. The paper explains the methodology process and illustrates the key tasks across three project phases of a Scan to BIM/Capture to CAD methodology: methods and activities developed with the students, from building survey, data processing, development of BIM models, etc. The aim of the paper is to analyse the positive contribution for the teaching curriculum and the benefits for community and industry. The paper is a reflective narrative piece and seeks to share useful tools and strategies to make educational use of a heritage building and its resources as one way of teaching architectural history and heritage today.

BSBin Su
Bin Su
RMRenata Jadresin Milic
Renata Jadresin Milic
PMPeter McPherson
Peter McPherson
LWLian Wu
Lian Wu
Based on field study data regarding the winter indoor thermal environment of three classrooms with different building envelopes, this study compared and evaluated these environments, not only related to students’ thermal comfort but also to their health. The inadequacy of the conventional New Zealand school building for maintaining a comfortable and healthy winter indoor thermal environment has been identified. A classroom with thermal mass had 31%, 34% and 9% more time than a classroom without thermal mass when indoor temperatures met 16 °C 18 °C and 20 °C respectively and has 21.4% more time than the classroom without thermal mass when indoor relative humidity was in the optimal range of 40% to 60%, in a temperate climate with a mild and humid winter. Adding thermal mass to school building envelopes should be considered as a strategy to improve the winter indoor thermal environment in future school design and development. Adding thermal mass to a school building with sufficient insulation can not only increase winter indoor mean air temperature but can also reduce the fluctuation of indoor air temperatures. This can significantly reduce the incidence of very low indoor temperature and very high indoor relative humidity, and significantly improve the indoor thermal environment.

1 June 2013 in Journal of Cultural Heritage
Verified
Journal Article
Closed access
MBMirjana Roter Blagojević
Mirjana Roter Blagojević
GMGordana Milošević
Gordana Milošević
RMRenata Jadresin Milic
Renata Jadresin Milic
MNMarko Nikolić
Marko Nikolić

22 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
BSBin Su
Bin Su
PMPeter McPherson
Peter McPherson
RMRenata Jadresin Milic
Renata Jadresin Milic
XWXinxin Wang
Xinxin Wang
SSSameh Shamout
Sameh Shamout
YLYifeng Liang
Yifeng Liang
Previous studies show that moderate thermal mass in school building elements can positively impact the winter indoor thermal environment in a temperate climate with mild, humid winters. Based on a field study, this research contributes new physical data of the summer indoor thermal environment of Auckland school buildings with different designs of moderate thermal mass in their building elements to add to the previous winter field-study data and demonstrates that a school building with moderate thermal mass is adequate in a temperate climate with mild, humid winters and warm, dry summers. This field study compared and evaluated the summer indoor thermal environment of classrooms with different moderate thermal mass in their building elements during the summer school term and the summer school holidays. This study found that a classroom with thermal mass in its building elements has 19% to 21% more time in summer than a classroom without any thermal mass in its building elements when indoor air temperatures are within the thermal comfort zone, which was solely impacted by the building’s thermal performance. This study established a suitable research method to analyse the field-study data and identify the differences in the indoor thermal environments of the school buildings with different designs of moderate thermal mass in their building elements.


27 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
BSBin Su
Bin Su
PMPeter McPherson
Peter McPherson
RMRenata Jadresin Milic
Renata Jadresin Milic
LWLian Wu
Lian Wu
Based on field studies, this study contributes the new physical data of winter indoor thermal conditions of the indoor spaces with four different dust mite allergen levels in New Zealand houses. This study provides a new method to identify the relationships between indoor thermal conditions and indoor dust mite allergen levels. This study found that the indoor mean relative humidity (RH) close to the floor must be controlled below 70%, and there must be less than 30% of time in winter when indoor RH close to the floor is higher than or equal to 75% to maintain indoor dust mite allergens at an undetectable level; and the indoor mean RH close to the floor must be controlled below 75%, and there must be less than 50% of time in winter when indoor RH close to the floor is higher than or equal to 75% to maintain indoor dust mite allergens at a low (acceptable) level. This study also identified the relationship between indoor thermal conditions for dust mites to thrive and for mould spores to germinate. This study provides a strategy or guideline for preventing indoor allergies related to dust mites and mould under the temperate climate zone; the winter is mild and humid.