Angelica Svalkvist

Dr. Angelica Svalkvist

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2016 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
ASAngelica Svalkvist
Angelica Svalkvist
SSSune Svensson
Sune Svensson
MHMarkus Håkansson
Markus Håkansson
MBMagnus Båth
Magnus Båth
LMLars Gunnar Månsson
Lars Gunnar Månsson
ViewDEX (Viewer for Digital Evaluation of X-ray images) is an image viewer and task manager suitable for research and optimisation tasks in medical imaging. The software has undergone continuous development during more than a decade and has during this time period been used in numerous studies. ViewDEX is DICOM compatible, and the features of the interface (tasks, image handling and functionality) are general and flexible. The set-up of a study is determined by altering properties in a text-editable file, enabling easy and flexible configuration. ViewDEX is developed in Java and can run from any disc area connected to a computer. It is free to use for non-commercial purposes and can be downloaded from http://www.vgregion.se/sas/viewdex. The purposes of the present article are to give a short overview of the development of ViewDEX and to describe recent updates of the software. In addition, a description on how to configure a viewing session in ViewDEX is provided.

10 December 2009 in Medical Physics
Verified
Journal Article
Closed access
ASAngelica Svalkvist
Angelica Svalkvist
MBMagnus Båth
Magnus Båth

4 March 2021 in Radiation Protection Dosimetry
Verified
Journal Article
Open access
PDF file
ASAngelica Svalkvist
Angelica Svalkvist
SSSune Svensson
Sune Svensson
THTommy Hagberg
Tommy Hagberg
MBMagnus Båth
Magnus Båth
ViewDEX (Viewer for Digital Evaluation of X-ray Images) is an image viewer compatible with Digital Imaging and Communications in Medicine (DICOM) that has been especially designed to facilitate image perception and observer performance studies within medical imaging. The software was first released in 2004 and since then a continuous development has been ongoing. One of the major drawbacks of previous versions of ViewDEX has been that they have lacked functionality enabling the possibility to evaluate multiple images and/or image stacks simultaneously. This functionality is especially requested by researchers working with modalities, where an image acquisition can result in multiple image stacks (e.g. axial, coronal and sagittal reformations in computed tomography). In ViewDEX 3.0 this functionality has been added and it is now possible to perform image evaluations of multiple images and/or image stacks simultaneously, by using multiple monitors and/or multiple image canvases in monitors. Additionally, some of the previously available functionality has been updated and improved. This paper describes the recent developments of ViewDEX 3.0.

3 March 2010 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
ASAngelica Svalkvist
Angelica Svalkvist
LMLars Gunnar MÅNsson
Lars Gunnar MÅNsson
MBMagnus BÅTh
Magnus BÅTh
The aims of this work were to explore the dosimetry of chest tomosynthesis and to determine conversion factors between air kerma-area product (KAP) and the effective dose for different system configurations and patient sizes. Tomosynthesis systems were modelled with different angular intervals and tube voltages for the collection of the projection images as well as different distributions of the total exposure over the projections. The Monte Carlo-based computer software PCXMC developed by STUK (Radiation and Nuclear Safety Authority in Finland) was used to calculate the effective doses for each modelled tomosynthesis system for various patient sizes. The conversion factor between KAP and effective dose was obtained both for the zero-degree projection alone and for the entire tomosynthesis examination for each system configuration and patient size. The results reveal that the conversion factor for the zero-degree projection can be used to estimate the total effective dose from a tomosynthesis examination with acceptable accuracy, leading to an error smaller than 10 % irrespective of the system configuration and patient size. For higher accuracy, conversion factors between the total KAP and the total effective dose that take the angular interval and exposure configuration into account are presented for each system.

1 April 2015 in Academic Radiology
Verified
Journal Article
Open access
CSChristina Söderman
Christina Söderman
ÅJÅse A. Johnsson
Åse A. Johnsson
JVJenny Vikgren
Jenny Vikgren
RNRauni R. Norrlund
Rauni R. Norrlund
DMDávid Molnár
Dávid Molnár
MBMagnus Båth
Magnus Båth
To investigate the accuracy and precision of pulmonary nodule size measurements on chest tomosynthesis images. Artificial ellipsoid-shaped nodules with known sizes were inserted in clinical chest tomosynthesis images. The volume of the nodules corresponded to that of a sphere with a diameter of 4.0, 8.0, or 12.0 mm. Four thoracic radiologists were given the task to determine the longest diameter of the nodules. All nodules were measured twice. Measurement accuracy in terms of the mean measurement error was determined. Intraobserver and interobserver variabilities, as well as variability because of differences between nodules and their locations, were used as measures of precision. The mean measurement error ranged from -0.3 to 0.1 mm for the nodule size groups and observers. Of the smallest nodules, the observers found 7-17 of total 50 nodules nonmeasurable. The intraobserver and interobserver variabilities were of similar magnitude, indicating relatively small differences between the observers. The internodule variability was in general larger, indicating that the different characteristics of the nodules and their location are sources of variability. The results suggest a high accuracy and precision for manual measurements of the nodules in chest tomosynthesis images. However, small nodules (<5.0 mm) may be difficult to measure at all because of poor visibility.

1 October 2012 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
ASAngelica Svalkvist
Angelica Svalkvist
ÅJÅse Allansdotter Johnsson
Åse Allansdotter Johnsson
JVJenny Vikgren
Jenny Vikgren
MHMarkus Håkansson
Markus Håkansson
GUGustaf Ullman
Gustaf Ullman
MBMagnus Båth
Magnus Båth
Background Simulated pathology is a valuable complement to clinical images in studies aiming at evaluating an imaging technique. In order for a study using simulated pathology to be valid, it is important that the simulated pathology in a realistic way reflect the characteristics of real pathology. Purpose To perform a thorough evaluation of a nodule simulation method for chest tomosynthesis, comparing the detection rate and appearance of the artificial nodules with those of real nodules in an observer performance experiment. Material and Methods A cohort consisting of 64 patients, 38 patients with a total of 129 identified pulmonary nodules and 26 patients without identified pulmonary nodules, was used in the study. Simulated nodules, matching the real clinically found pulmonary nodules by size, attenuation, and location, were created and randomly inserted into the tomosynthesis section images of the patients. Three thoracic radiologists and one radiology resident reviewed the images in an observer performance study divided into two parts. The first part included nodule detection and the second part included rating of the visual appearance of the nodules. The results were evaluated using a modified receiver-operating characteristic (ROC) analysis. Results The sensitivities for real and simulated nodules were comparable, as the area under the modified ROC curve (AUC) was close to 0.5 for all observers (range, 0.43–0.55). Even though the ratings of visual appearance for real and simulated nodules overlapped considerably, the statistical analysis revealed that the observers to were able to separate simulated nodules from real nodules (AUC values range 0.70–0.74). Conclusion The simulation method can be used to create artificial lung nodules that have similar detectability as real nodules in chest tomosynthesis, although experienced thoracic radiologists may be able to distinguish them from real nodules.