This study contributes to social studies of imaging and visualization practices within scientific and medical settings. The focus is on practices in radiology, which are bound up with visual records known as radiographs. The study addresses work following the introduction of a new imaging technology, tomosynthesis. Since it was a novel technology, there was limited knowledge of how to correctly analyse tomosynthesis images. To address this problem, a collective review session was arranged. The purpose of the present study was to uncover the practical work that took place during that session and to show how, and on what basis, new methods, interpretations and understandings were being generated. The analysis displays how the diagnostic work on patients’ bodies was grounded in two sets of technologically produced renderings. This shows how expertise is not simply a matter of providing correct explanations, but also involves discovery work in which visual renderings are made transparent. Furthermore, the results point to how the disciplinary knowledge is intertwined with timely actions, which in turn, partly rely on established practices of manipulating and comparing images. The embodied and situated reasoning that enabled radiologists to discern objects in the images thus display expertise as inherently practical and domain-specific.
To investigate the accuracy and precision of pulmonary nodule size measurements on chest tomosynthesis images. Artificial ellipsoid-shaped nodules with known sizes were inserted in clinical chest tomosynthesis images. The volume of the nodules corresponded to that of a sphere with a diameter of 4.0, 8.0, or 12.0 mm. Four thoracic radiologists were given the task to determine the longest diameter of the nodules. All nodules were measured twice. Measurement accuracy in terms of the mean measurement error was determined. Intraobserver and interobserver variabilities, as well as variability because of differences between nodules and their locations, were used as measures of precision. The mean measurement error ranged from -0.3 to 0.1 mm for the nodule size groups and observers. Of the smallest nodules, the observers found 7-17 of total 50 nodules nonmeasurable. The intraobserver and interobserver variabilities were of similar magnitude, indicating relatively small differences between the observers. The internodule variability was in general larger, indicating that the different characteristics of the nodules and their location are sources of variability. The results suggest a high accuracy and precision for manual measurements of the nodules in chest tomosynthesis images. However, small nodules (<5.0 mm) may be difficult to measure at all because of poor visibility.
This paper aimed to study the agreement and repeatability, both intra- and interobserver, of infrapopliteal lesion assessment with magnetic resonance angiography (MRA), using the TransAtlantic Inter-Society Consensus (TASC) II criteria, with perioperative digital subtraction angiography (DSA) as a reference. Sixty-eight patients with an MRA preceding an endovascular infrapopliteal revascularization were included. Preoperative MRAs and perioperative DSAs were evaluated in random order by three independent observers using the TASC II classification. The results were analyzed using visual grading characteristics (VGC) analysis and Krippendorff’s α. No systematic difference was found between modalities: area under the VGC curve (AUCVGC) = 0.48 (p = 0.58) or intraobserver; AUCVGC for Observer 1 and 2 respectively, 0.49 (p = 0.85) and 0.53 (p = 0.52) for MRA compared with 0.54 (p = 0.30) and 0.49 (p = 0.81) for DSA. Interobserver differences were seen: AUCVGC of 0.63 (p < 0.01) for DSA and 0.80 (p < 0.01) for MRA. These results were confirmed using Krippendorff’s α for the three observers showing 0.13 (95% confidence interval (CI) −0.07–0.31) for MRA and 0.39 (95% CI 0.23–0.53) for DSA. Poor interobserver agreement was also found in the choice of a target vessel on preoperative MRA: Krippendorff’s α = 0.19 (95% CI 0.01‒0.36). In conclusion, infrapopliteal lesions can be reliably determined on preoperative MRA, but interobserver variability regarding the choice of a target vessel is a major concern that appears to affect the overall TASC II grade.
The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively.
<!-- *** Custom HTML *** --> Purpose: To show that adjustment of velocity encoding (VENC) for phase-contrast (PC) flow volume measurements is not necessary in modern MR scanners with effective background velocity offset corrections. Approach: The independence on VENC was demonstrated theoretically, but also experimentally on dedicated phantoms and on patients with chronic aortic regurgitation (n = 17) and one healthy volunteer. All PC measurements were performed using a modern MR scanner, where the pre-emphasis circuit but also a subsequent post-processing filter were used for effective correction of background velocity offset errors. Results: The VENC level strongly affected the velocity noise level in the PC images and, hence, the estimated peak flow velocity. However, neither the regurgitant blood flow volume nor the mean flow velocity displayed any clinically relevant dependency on the VENC level. Also, the background velocity offset was shown to be close to zero (<0.6 cm / s) for a VENC range of 150 to 500 cm / s, adding no significant errors to the PC flow volume measurement. Conclusions: Our study shows that reliable PC flow volume measurements are feasible without adjustment of the VENC parameter. Without the need for VENC adjustments, the scan time can be reduced for the benefit of the patient.
Background: The role of the lung for the initiation and progression of rheumatoid arthritis (RA) is still unclear. Up to 10% of RA patients develop interstitial lung disease which remains a clinical challenge. Understanding early disease mechanisms is of great importance. The objective of this study was to determine whether there is an association between peripheral neutrophil phenotypes and presence of pulmonary abnormalities (PA) on chest high-resolution computed tomography (HRCT) in untreated early RA (ueRA).Methods: Clinical data and blood were collected, and HRCT performed at diagnosis on 30 consecutive anti-citrullinated protein antibody (ACPA) and/or rheumatoid factor (RF) positive ueRA patients. HRCTs were evaluated for the presence of RA-associated parenchymal, airway and/or pleural abnormalities. Expression of phenotype markers on neutrophils were determined by flow cytometry. Levels of calprotectin, ACPA and RF were measured using immunoassays.Results: The frequency of having any PA was 60%. Airway abnormalities were present in 50%, parenchymal nodules in 43% and interstitial lung abnormalities (ILA) in 10%. Unsupervised multivariate data analysis showed clustering of any PA with neutrophil activation, parameters of inflammation and RF titres. In univariate analysis, the patients with PA displayed significantly increased CD11b and decreased CD62L expression on neutrophils (1.2-fold,p = 0.014; 0.8-fold,p = 0.012) indicating activation and significantly increased RF IgM titre and CRP (5.7-fold,p = 0.0025; 2.3-fold,p = 0.0035) as compared to no PA. Titres of RF, but not ACPA, correlated with expression of the neutrophil activation marker CD11b. A stratified analysis demonstrated that airway involvement was the PA subtype with the strongest association with neutrophil activation.Conclusion: We report a strong association between radiographic airway findings and activation of circulating neutrophils in early RA supporting a role of innate immunity and the lung at disease onset. Our results also indicate different contributions of RF and ACPA in the RA pathogenesis.