Livestock slurry has been reported to be a potential secondary raw material as it contains macronutrients ‑nitrogen, phosphorus and potassium-, which could be valorised as high-quality fertilizers if proper separation and concentration of valuable compounds is performed. In this work, pig slurry liquid fraction was assessed for nutrient recovery and valorisation as fertilizer. Some indicators were used to evaluate the performance of proposed train of technologies within the framework of circular economy. As ammonium and potassium species are highly soluble at the whole pH range, a study based on phosphate speciation at pH from 4 to 8 was assessed to improve the macronutrients recovery from the slurry, resulting in two different treatment trains at acidic and alkaline conditions. The acidic treatment system based on centrifugation, microfiltration and forward osmosis was applied to obtain a nutrient-rich liquid organic fertilizer containing 1.3 % N, 1.3 % P2O5 and 1.5 % K2O. The alkaline path of valorisation was composed by centrifugation and stripping by using membrane contactors to produce an organic solid fertilizer −7.7 % N, 8,0 % P2O5 and 2.3 % K2O-, ammonium sulphate solution −1.4 % N- and irrigation water. In terms of circularity indicators, 45.8 % of the initial water content and <50 % of contained nutrients were recovered - 28.3 % N, 43.5 % P2O5 and 46.6 % K2O - in the acidic treatment resulting in 68.68 g fertilizer per kg of treated slurry. 75.1 % of water was recovered as irrigation water and 80.6 % N, 99.9 % P2O5, 83.4 % K2O was valorised in the alkaline treatment, as 219.60 g fertilizer per kg of treated slurry. Treatment paths at acidic and alkaline conditions yield promising results for nutrients recovery and valorisation as the obtained products (nutrient rich organic fertilizer, solid soil amendment and ammonium sulphate solution) fulfil the European Regulation for fertilizers to be potentially used in crop fields.
1 October 2021 in Cleaner Engineering and Technology
This study investigated the efficiency of two advanced oxidation processes (AOPs), ozonation (O3), and electrochemical oxidation (EO), applied individually or in combination, in the removal of contaminants of emerging concern (CECs) contained in hospital wastewaters, focusing on pharmaceuticals. The optimisation of the single technologies was performed using synthetic wastewater composed of four refractory pharmaceuticals, (carbamazepine-CBZ, lorazepam-LZP, ketoprofen-KTP, 10,11-epoxicarbamazepine-E-CBZ), first alone and then in mixture, in an initial concentration of 1 mg L−1 each. Once the best operational conditions for EO and O3 were defined, their combination (both simultaneous and sequential) was evaluated for the mixture of the selected pharmaceuticals. The treatment solution that showed the best performance was the simultaneous combination of O3 and EO. This treatment was validated using real hospital wastewater previously treated through a moving bed biofilm reactor (MBBR), evaluating its viability by testing the toxicity of the final effluent via Vibrio fischeri inhibition tests. The obtained results showed that the simultaneous combination of O3 and EO as the polishing step after a biological treatment is a very promising solution for hospital wastewater treatment, allowing for obtaining a non-toxic effluent and full degradation of refractory compounds. The disinfection potential of the proposed AOP was also assessed by determining Escherichia coli inactivation potential.
Simultaneous application of solar photo-Fenton and ozonation (SPFO) for the efficient treatment of real wastewaters was studied. Four different industrial effluents were selected for the study: landfill leachate, pharmaceutical effluent and two textile wastewaters, in order to demonstrate the effectiveness and versatility of the proposed technology. SPFO performance was compared with individual processes (either solar photo-Fenton or ozonation), as well as the hybrid Fenton and ozonation treatment. In highly polluted wastewaters, combined strategies led to higher organic matter removal than O3 and photo-Fenton processes applied individually. Solar light favoured catalyst regeneration, allowing removal efficiencies up to 67% of chemical oxygen demand (COD) and 62% of total organic carbon (TOC) (in the case of textile wastewaters) using an initial concentration of only 10 mg Fe2+ L−1. The reduction of catalyst consumption, along with the absence of sludge production (since Fe2+ removal from the effluent is not required), led to a significant decrease in operational costs (up to 1.22 € kg−1 COD removed) when combined Fenton and ozonation was applied under solar light. SPFO results in a versatile, effective and economically efficient technology, thus postulating as a promising alternative for reducing the organic load of highly polluted industrial effluents prior to biological treatment.
The increasing food demand for a growing population has resulted in the intensification and modernization of agriculture leading to an increasing use of pesticides to protect crops against insects, weeds, fungi, and other pests. These chemical compounds are time-persistant as they usually report low biodegradability and can cause adverse effects on the environment due to their toxicity. This study assesses the use of membranes designed for urban wastewater and drinking water treatment -DuPont FilmTec™ NF270 and FilmTec™ XLE membranes- for the removal of six pesticides (atrazine, simazine, isoproturon, metolachlor ESA, 2,4-D, and chlorothalonil) from aqueous streams. The results reported average rejection rates of 29–89% in the case of nanofiltration membranes and > 97% for reverse osmosis membranes. In addition, it was observed adsorption of pesticides within membranes’ active layer, which should be taken into account for the assessment of membranes performance when a fresh membrane is used. From this study can be concluded that membrane-based technology is effective for the removal of these pollutants from aqueous streams, but a customised selection of the membrane (nanofiltration/reverse osmosis) should be performed depending on the targeted pollutants in order to balance the pesticide rejection and energy consumption for each market application.