Tim Kovachy

Prof. Tim Kovachy

Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Physical Review A
Verified
Journal Article
Closed access
PDF file
ZCZilin Chen
Zilin Chen
GLGarrett Louie
Garrett Louie
YWYiping Wang
Yiping Wang
TDTejas Deshpande
Tejas Deshpande
Tim KovachyTim Kovachy
Tim Kovachy
Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. This could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

11 December 2024 in Physical Review Letters
Verified
Journal Article
Closed access
YWYiping Wang
Yiping Wang
JGJonah Glick
Jonah Glick
TDTejas Deshpande
Tejas Deshpande
KDKenneth DeRose
Kenneth DeRose
SSSharika Saraf
Sharika Saraf
Tim KovachyTim Kovachy
Tim Kovachy
We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

10 January 2024 in AVS Quantum Science
Verified
Journal Article
Closed access
PDF file
JGJonah Glick
Jonah Glick
ZCZilin Chen
Zilin Chen
TDTejas Deshpande
Tejas Deshpande
YWYiping Wang
Yiping Wang
Tim KovachyTim Kovachy
Tim Kovachy
The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

3 August 2021 in Atoms
Verified
Journal Article
Open access
PDF file
JLJinyang Li
Jinyang Li
GSGregório R. M. da Silva
Gregório R. M. da Silva
WHWayne C. Huang
Wayne C. Huang
MFMohamed Fouda
Mohamed Fouda
JBJason Bonacum
Jason Bonacum
Selim ShahriarSelim Shahriar
Selim Shahriar
A point source interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses during the expansion of a cloud of cold atoms behaving approximately as a point source. The PSI can work as a sensitive multi-axes gyroscope that can automatically filter out the signal from accelerations. The phase shift arising from the rotations is proportional to the momentum transferred to each atom from the Raman pulses. Therefore, by increasing the momentum transfer, it should be possible to enhance the sensitivity of the PSI. Here, we investigate the degree of enhancement in sensitivity that could be achieved by augmenting the PSI with large momentum transfer (LMT) employing a sequence of many Raman pulses with alternating directions. We analyze how factors such as Doppler detuning, spontaneous emission, and the finite initial size of the atomic cloud compromise the advantage of LMT and how to find the optimal momentum transfer under these limitations, with both the semi-classical model and a model under which the motion of the center of mass of each atom is described quantum mechanically. We identify a set of realistic parameters for which LMT can improve the PSI by a factor of nearly 40.

19 July 2023 in Optics Letters
Verified
Journal Article
Closed access
KDKenneth DeRose
Kenneth DeRose
TDTejas Deshpande
Tejas Deshpande
YWYiping Wang
Yiping Wang
Tim KovachyTim Kovachy
Tim Kovachy
We present a laser system for performing single-photon atom interferometry on the 698 nm clock transition in ultracold strontium. We coherently combine the power of two titanium:sapphire lasers and demonstrate chirps of 200 MHz in 2.5 ms while phase-locked to an optical reference. Moreover, we demonstrate a novel, to the best of our knowledge, scheme to deliver 4 W pulsed beams to the atoms via a mode-cleaning optical fiber using active noise cancellation.

9 April 2025 in Physical Review D
Verified
Journal Article
Open access
JCJohn Carlton
John Carlton
VGValerie Gibson
Valerie Gibson
Tim KovachyTim Kovachy
Tim Kovachy
CMChristopher McCabe
Christopher McCabe
JMJeremiah Mitchell
Jeremiah Mitchell
Terrestrial long-baseline atom interferometer experiments are emerging as powerful tools for probing new fundamental physics, including searches for dark matter and gravitational waves. In the frequency range relevant to these signals, gravity gradient noise (GGN) poses a significant challenge. While previous studies for vertical instruments have focused on GGN induced by seismic waves, atmospheric fluctuations in pressure and temperature also lead to variations in local gravity. In this work, we advance the understanding of atmospheric GGN in vertical atom interferometers, formulating a robust characterization of its impact. We evaluate the effectiveness of underground placement of atom interferometers as a passive noise mitigation strategy. Additionally, we empirically derive global high- and low-noise models for atmospheric pressure GGN and estimate an analogous range for atmospheric temperature GGN. To highlight the variability of temperature-induced noise, we compare data from three prospective experimental sites. Our findings establish atmospheric GGN as comparable to seismic noise in its impact and underscore the importance of including these effects in site selection and active noise monitoring for future experiments.