Angelika Hackner

Mrs. Angelika Hackner


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2016 in Materials
Verified
Journal Article
Open access
PDF file
GMGerhard Müller
Gerhard Müller
AHAngelika Hackner
Angelika Hackner
SBSebastian Beer
Sebastian Beer
JGJohann Göbel
Johann Göbel
The detection of military high explosives and illicit drugs presents problems of paramount importance in the fields of counter terrorism and criminal investigation. Effectively dealing with such threats requires hand-portable, mobile and affordable instruments. The paper shows that solid-state gas sensors can contribute to the development of such instruments provided the sensors are incorporated into integrated sensor systems, which acquire the target substances in the form of particle residue from suspect objects and which process the collected residue through a sequence of particle sampling, solid-vapor conversion, vapor detection and signal treatment steps. Considering sensor systems with metal oxide gas sensors at the backend, it is demonstrated that significant gains in sensitivity, selectivity and speed of response can be attained when the threat substances are sampled in particle as opposed to vapor form.

6 December 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GMGerhard Müller
Gerhard Müller
JPJ. Daniel Prades
J. Daniel Prades
AHAngelika Hackner
Angelika Hackner
Andrea PonzoniAndrea Ponzoni
Andrea Ponzoni
Elisabetta CominiElisabetta Comini
Elisabetta Comini
Giorgio SberveglieriGiorgio Sberveglieri
Giorgio Sberveglieri
Surface ionization (SI) provides a simple, sensitive, and selective method for the detection of high-proton affinity substances, such as organic decay products, medical and illicit drugs as well as a range of other hazardous materials. Tests on different kinds of SI sensors showed that the sensitivity and selectivity of such devices is not only dependent on the stoichiometry and nanomorphology of the emitter materials, but also on the shape of the electrode configurations that are used to read out the SI signals. Whereas, in parallel-plate capacitor devices, different kinds of emitter materials exhibit a high level of amine-selectivity, MEMS (micro-electro-mechanical-systems) and NEMS (nanowire) versions of SI sensors employing the same kinds of emitter materials provide significantly higher sensitivity, however, at the expense of a reduced chemical selectivity. In this paper, it is argued that such sensitivity-selectivity trade-offs arise from unselective physical ionization phenomena that occur in the high-field regions immediately adjacent to the surfaces of sharply curved MEMS (NEMS) emitter and collector electrodes.

3 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AHAndreas Helwig
Andreas Helwig
AHAngelika Hackner
Angelika Hackner
GMGerhard Müller
Gerhard Müller
Dario ZappaDario Zappa
Dario Zappa
Giorgio SberveglieriGiorgio Sberveglieri
Giorgio Sberveglieri
Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the help of an external micro-pump, such systems can be operated in a periodic manner alternating between flow and no-flow conditions, thus allowing repetitive measurements of the sensor resistances under clean air, R 0 , and under gas exposure, R g a s , to be obtained, even under field conditions. With these pairs of resistance values, eventual drifts in the sensor baseline resistance can be detected and drift-corrected values of the relative resistance response R e s p = ( R 0 − R g a s ) / R 0 can be determined. Residual poisoning-induced changes in the relative resistance response can be detected by reference to humidity measurements taken with room-temperature-operated capacitive humidity sensors which are insensitive to the poisoning processes operative on heated MOX gas sensors.