A simple and reliable ultraviolet sensing method with high sensitivity is proposed. ZnO and ZnO composite graphene are successfully prepared by the hydrothermal method. The optical fiber sensor is fabricated by coating the single-mode-taper multimode-single-mode (STMS) with different shapes of ZnO. The effects of the sensitivity of ultraviolet sensors are further investigated. The results show that the sensor with ZnO nanosheets exhibits a higher sensitivity of 357.85 pm/nW·cm−2 for ultraviolet sensing ranging from 0 to 4 nW/cm2. The ultraviolet characteristic of STMS coated flake ZnO composite graphene has been demonstrated with a sensitivity of 427.76 pm/nW·cm−2. The combination of sensitive materials and optical fiber sensing technology provides a novel and convenient platform for ultraviolet detection technology.
A twin-core sensor with high birefringence employing a photonic crystal fiber (PCF) is presented for simulated temperature measurements based on surface plasmon resonance (SPR). The internal wall of the central hole of the PCF is plated with gold and coated with graphene oxide (Au-GO) to develop an SPR sensing channel. The results of a numerical analysis with COMSOL Multiphysics show that the birefringence of this sensing structure can reach 0.0052. In addition, an average sensitivity of -12.695 nm/°C can be achieved in the range of 0°C~80°C. Compared with uncoated GO sensors and existing sensing units, this sensor shows improved stability, sensitivity and birefringence.
A simple and reliable temperature sensing method with high sensitivity is proposed. ZnO composite graphene sensitive materials with different shapes are successfully prepared by hydrothermal method and characterized by scanning electron microscpoy. The sensor is fabricated by coating the singlemode-taper multimode-singlemode with ZnO composite graphene. The effects of different shapes of ZnO composite graphene on the sensitivity of temperature sensors are further investigated. The electron migration rate of ZnO composite graphene is changed by temperature change. Furthermore, the surface refractive index of the optical microfiber changes. The results show that the sensor with floriated ZnO composite graphene exhibits a high sensitivity of 282.48 pm °C for temperature ranging from 30 °C to 48 °C, which provides a novel and convenient platform for temperature sensing.
To reduce the complexity of the sensor structure and improve the sensitivity of refractive index (RI) measurement, a D-shaped photonic crystal fiber (PCF) surface plasmon resonance (SPR) RI sensor with incomplete coating of gold-tantalum pentoxide (Au-Ta2O5) on the surface is proposed. When the coating width is 3.1 μm, the sensor can detect RI samples ranging from 1.35 to 1.41 in the ultra-wide near-infrared (NIR) region of 1100–2100 nm wavelength. Its maximum wavelength sensitivity is 20,000 nm RIU−1, maximum amplitude sensitivity is 2817.7 RIU−1, resolution is RIU, and figure of merit (FOM) is 333.3 RIU−1. This sensor can be widely used in biological tissue detection. For this type of incomplete coated D-shaped sensor, the coating material and structural parameters not only affect the performance of the sensor, but also change the RI detection range, which has been ignored or not mentioned in previous literature on PCF-SPR sensors. Therefore, the reasons for the change of RI detection interval and negative optimization caused by structural parameters were analyzed, and two different sensors with different coating widths were finally obtained, which can achieve high sensitivity sensing in their respective detection intervals. The detailed research results expand the understanding of the SPR phenomenon in D-shaped PCF and provide theoretical guidance for adjusting and improving the detection performance of PCF-SPR sensors.