Feng Yue

Ms. Feng Yue


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in Plasmonics
Verified
Journal Article
Closed access
PDF file
HLHan Liang
Han Liang
FYFeng Yue
Feng Yue
HLHongchen Liu
Hongchen Liu
WHWei Han
Wei Han
TSTao Shen
Tao Shen

8 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TSTao Shen
Tao Shen
XDXiaoshuang Dai
Xiaoshuang Dai
DZDaqing Zhang
Daqing Zhang
WWWenkang Wang
Wenkang Wang
FYFeng Yue
Feng Yue
A simple and reliable ultraviolet sensing method with high sensitivity is proposed. ZnO and ZnO composite graphene are successfully prepared by the hydrothermal method. The optical fiber sensor is fabricated by coating the single-mode-taper multimode-single-mode (STMS) with different shapes of ZnO. The effects of the sensitivity of ultraviolet sensors are further investigated. The results show that the sensor with ZnO nanosheets exhibits a higher sensitivity of 357.85 pm/nW·cm−2 for ultraviolet sensing ranging from 0 to 4 nW/cm2. The ultraviolet characteristic of STMS coated flake ZnO composite graphene has been demonstrated with a sensitivity of 427.76 pm/nW·cm−2. The combination of sensitive materials and optical fiber sensing technology provides a novel and convenient platform for ultraviolet detection technology.

15 April 2020 in IEEE Photonics Journal
Verified
Journal Article
Open access
HLHan Liang
Han Liang
TSTao Shen
Tao Shen
FYFeng Yue
Feng Yue
ZXZhentao Xia
Zhentao Xia
Liu HongchenLiu Hongchen
Liu Hongchen
A twin-core sensor with high birefringence employing a photonic crystal fiber (PCF) is presented for simulated temperature measurements based on surface plasmon resonance (SPR). The internal wall of the central hole of the PCF is plated with gold and coated with graphene oxide (Au-GO) to develop an SPR sensing channel. The results of a numerical analysis with COMSOL Multiphysics show that the birefringence of this sensing structure can reach 0.0052. In addition, an average sensitivity of -12.695 nm/°C can be achieved in the range of 0°C~80°C. Compared with uncoated GO sensors and existing sensing units, this sensor shows improved stability, sensitivity and birefringence.

23 March 2022 in Optics Communications
Verified
Journal Article
Closed access
TYTianyu Yang
Tianyu Yang
CLChi Liu
Chi Liu
XLXin Liu
Xin Liu
FYFeng Yue
Feng Yue
TSTao Shen
Tao Shen
WHWei Han
Wei Han

9 June 2020 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
TSTao Shen
Tao Shen
XDXiaoshuang Dai
Xiaoshuang Dai
BLBing Li
Bing Li
DZDaqing Zhang
Daqing Zhang
WWWenkang Wang
Wenkang Wang
FYFeng Yue
Feng Yue
A simple and reliable temperature sensing method with high sensitivity is proposed. ZnO composite graphene sensitive materials with different shapes are successfully prepared by hydrothermal method and characterized by scanning electron microscpoy. The sensor is fabricated by coating the singlemode-taper multimode-singlemode with ZnO composite graphene. The effects of different shapes of ZnO composite graphene on the sensitivity of temperature sensors are further investigated. The electron migration rate of ZnO composite graphene is changed by temperature change. Furthermore, the surface refractive index of the optical microfiber changes. The results show that the sensor with floriated ZnO composite graphene exhibits a high sensitivity of 282.48 pm °C for temperature ranging from 30 °C to 48 °C, which provides a novel and convenient platform for temperature sensing.

18 September 2023 in Physica Scripta
Verified
Journal Article
Closed access
HJHaoran Jiang
Haoran Jiang
TSTao Shen
Tao Shen
FYFeng Yue
Feng Yue
CLChi Liu
Chi Liu
XLXin Liu
Xin Liu
THTang Hujun
Tang Hujun
To reduce the complexity of the sensor structure and improve the sensitivity of refractive index (RI) measurement, a D-shaped photonic crystal fiber (PCF) surface plasmon resonance (SPR) RI sensor with incomplete coating of gold-tantalum pentoxide (Au-Ta2O5) on the surface is proposed. When the coating width is 3.1 μm, the sensor can detect RI samples ranging from 1.35 to 1.41 in the ultra-wide near-infrared (NIR) region of 1100–2100 nm wavelength. Its maximum wavelength sensitivity is 20,000 nm RIU−1, maximum amplitude sensitivity is 2817.7 RIU−1, resolution is 5 × 10 − 6 RIU, and figure of merit (FOM) is 333.3 RIU−1. This sensor can be widely used in biological tissue detection. For this type of incomplete coated D-shaped sensor, the coating material and structural parameters not only affect the performance of the sensor, but also change the RI detection range, which has been ignored or not mentioned in previous literature on PCF-SPR sensors. Therefore, the reasons for the change of RI detection interval and negative optimization caused by structural parameters were analyzed, and two different sensors with different coating widths were finally obtained, which can achieve high sensitivity sensing in their respective detection intervals. The detailed research results expand the understanding of the SPR phenomenon in D-shaped PCF and provide theoretical guidance for adjusting and improving the detection performance of PCF-SPR sensors.