Jun-Young Kim

Prof. Jun-Young Kim

Daegu Cathollic University Medical Center

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KLKyungsu Lee
Kyungsu Lee
JKJun-Young Kim
Jun-Young Kim
MLMOONHWAN LEE
MOONHWAN LEE
CCChang-Hyuk Choi
Chang-Hyuk Choi
JHJae Youn Hwang
Jae Youn Hwang
A rotator cuff tear (RCT) is an injury in adults that causes difficulty in moving, weakness, and pain. Only limited diagnostic tools such as magnetic resonance imaging (MRI) and ultrasound Imaging (UI) systems can be utilized for an RCT diagnosis. Although UI offers comparable performance at a lower cost to other diagnostic instruments such as MRI, speckle noise can occur the degradation of the image resolution. Conventional vision-based algorithms exhibit inferior performance for the segmentation of diseased regions in UI. In order to achieve a better segmentation for diseased regions in UI, deep-learning-based diagnostic algorithms have been developed. However, it has not yet reached an acceptable level of performance for application in orthopedic surgeries. In this study, we developed a novel end-to-end fully convolutional neural network, denoted as Segmentation Model Adopting a pRe-trained Classification Architecture (SMART-CA), with a novel integrated on positive loss function (IPLF) to accurately diagnose the locations of RCT during an orthopedic examination using UI. Using the pre-trained network, SMART-CA can extract remarkably distinct features that cannot be extracted with a normal encoder. Therefore, it can improve the accuracy of segmentation. In addition, unlike other conventional loss functions, which are not suited for the optimization of deep learning models with an imbalanced dataset such as the RCT dataset, IPLF can efficiently optimize the SMART-CA. Experimental results have shown that SMART-CA offers an improved precision, recall, and dice coefficient of 0.604% (+38.4%), 0.942% (+14.0%) and 0.736% (+38.6%) respectively. The RCT segmentation from a normal ultrasound image offers the improved precision, recall, and dice coefficient of 0.337% (+22.5%), 0.860% (+15.8%) and 0.484% (+28.5%), respectively, in the RCT segmentation from an ultrasound image with severe speckle noise. The experimental results demonstrated the IPLF outperforms other conventional loss functions, and the proposed SMART-CA optimized with the IPLF showed better performance than other state-of-the-art networks for the RCT segmentation with high robustness to speckle noise.

1 September 2020 in Clinics in Shoulder and Elbow
Verified
Journal Article
Open access
PDF file
CCChang-Hyuk Choi
Chang-Hyuk Choi
HKHeechan Kim
Heechan Kim
DKDaewon Kang
Daewon Kang
JKJun-Young Kim
Jun-Young Kim
Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models.Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise).Results: Mean glenoid version and inclination in 2D measurements were –1.705º and 9.08º, respectively, while those in 3D measurements were 2.635º and 7.23º. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while those in 3D measurements was 0.853 and 0.845.Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.

1 January 2018 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
SLSeongpung Lee
Seongpung Lee
JKJun-Young Kim
Jun-Young Kim
JHJaesung Hong
Jaesung Hong
SBSeung-Hoon Baek
Seung-Hoon Baek
SKShin-Yoon Kim
Shin-Yoon Kim
Lee S, et al. Yonsei Med J. 2018 Aug;59(6):769-780. https://doi.org/10.3349/ymj.2018.59.6.769

17 April 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JCJaesuk Choi
Jaesuk Choi
JKJihun Kim
Jihun Kim
JHJae Youn Hwang
Jae Youn Hwang
MJMinkyu Je
Minkyu Je
JKJun-Young Kim
Jun-Young Kim
SKShin-Yoon Kim
Shin-Yoon Kim
This paper proposes a novel smart surgical navigation system for intramedullary nailing in orthopedic surgery. Using a handle-integrated laser guidance module, the system can target a drill insertion point onto skin, indicating an accurate target position to perpendicularly access an invisible distal hole. The proposed handle-integration-based fixation of the laser guidance module precisely defines the relative position of the module with respect to the distal hole. Consequently, unlike conventional systems, the proposed system can indicate the target insertion point without any help from bulky and costly external position-tracking equipment that is usually required for compensating disturbances generated by external impacts. After insertion, a correct drilling direction toward the distal hole is guided by real-time drilling angle measurement modules–one integrated with the nail handle and the other with the drill body. Each module contains a 9-axis inertial sensor and a Bluetooth communication device. These two modules work together to provide real-time drilling angle data, allowing calculation of the directional error toward the center of the distal hole in real time. The proposed system removes the need for fluoroscopy and provides a compact and cost-effective solution compared with conventional systems.

6 January 2017 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
JPJaeyeong Park
Jaeyeong Park
JKJun-Young Kim
Jun-Young Kim
HKHyun Deok Kim
Hyun Deok Kim
YKYoung Cheol Kim
Young Cheol Kim
ASAnna Seo
Anna Seo
SKShin-Yoon Kim
Shin-Yoon Kim

6 April 2020 in IEEE Access
Verified
Journal Article
Open access
MLMOONHWAN LEE
MOONHWAN LEE
JKJun-Young Kim
Jun-Young Kim
KLKyungsu Lee
Kyungsu Lee
CCChang-Hyuk Choi
Chang-Hyuk Choi
JHJae Youn Hwang
Jae Youn Hwang
Rotator cuff tear (RCT) is a common injury that causes pain and disability in adults. The quantitative diagnosis of the RCT can be crucial in determining a treatment plan or monitoring treatment efficacy. Currently, only a few diagnosis tools, such as magnetic resonance imaging (MRI) and ultrasound imaging (US), are utilized for the diagnosis. Specifically, US exhibited comparable performance with MRI while offering a readily available diagnosis of RCTs at a lower cost. However, three-dimensional(3D) US and analysis of the regions are necessary to enable a better diagnosis of RCTs. Therefore, we developed a wide-field 3D US platform with a semi-automatic 3D image segmentation algorithm for 3D quantitative diagnosis of RCTs. The 3D US platform is built based on a conventional 2D US system and obtains 3D US images via linear scanning. With respect to 3D segmentation algorithm based on active contour model, frequency compounding and anisotropic diffusion methods were applied, and their effects on segmentation were discussed. The platform was used for clinical examination after evaluating the platform via the RCT-mimicking phantoms. As verified by the Dice coefficient(average DC: 0.663, volume DC: 0.723), which was approximately up to 50% higher than that obtained with conventional algorithms, the RCT regions segmented by the developed algorithm significantly matched the ground truth. The results indicated that the wide-field 3D US platform with the 3D segmentation algorithm can constitute a useful tool for improving the accuracy in the diagnosis of RCTs, and can eventually lead to better determination of treatment plans and surgical planning.