MOONHWAN LEE

Mr. MOONHWAN LEE

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MLMOONHWAN LEE
MOONHWAN LEE
HLHah Min Lew
Hah Min Lew
SYSangyeon Youn
Sangyeon Youn
TKTae Kim
Tae Kim
JHJae Youn Hwang
Jae Youn Hwang
Acoustic holography has been gaining attention for various applications such as non-contact particle manipulation, non-invasive neuromodulation, and medical imaging. However, only a few studies on how to generate acoustic holograms have been conducted, and even conventional acoustic hologram algorithms show limited performance in the fast and accurate generation of acoustic holograms, thus hindering the development of novel applications. We here propose a deep learning-based framework to achieve fast and accurate acoustic hologram generation. The framework has an autoencoder-like architecture; thus the unsupervised training is realized without any ground truth. For the framework, we demonstrate a newly developed hologram generator network, the Holographic Ultrasound generation Network (HU-Net), which is suitable for unsupervised learning of hologram generation, and a novel loss function that is devised for energy-efficient holograms. Furthermore, for considering various hologram devices (i.e., ultrasound transducers), we propose a physical constraint layer. Simulation and experimental studies were carried out for two different hologram devices such as a 3D printed lens, attached to a single element transducer, and a 2D ultrasound array. The proposed framework was compared with the iterative angular spectrum approach (IASA) and the state-of-the-art iterative optimization method, Diff-PAT. In the simulation study, our framework showed a few hundred times faster generation speed, along with comparable or even better reconstruction quality, than those of IASA and Diff-PAT. In the experimental study, the framework was validated with 3D-printed lenses fabricated based on different methods, and the physical effect of the lenses on the reconstruction quality was discussed. The outcomes of the proposed framework in various cases (i.e., hologram generator networks, loss functions, hologram devices) suggest that our framework may become a very useful alternative tool for other existing acoustic hologram applications and it can expand novel medical applications.

22 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KLKyungsu Lee
Kyungsu Lee
JKJun-Young Kim
Jun-Young Kim
MLMOONHWAN LEE
MOONHWAN LEE
CCChang-Hyuk Choi
Chang-Hyuk Choi
JHJae Youn Hwang
Jae Youn Hwang
A rotator cuff tear (RCT) is an injury in adults that causes difficulty in moving, weakness, and pain. Only limited diagnostic tools such as magnetic resonance imaging (MRI) and ultrasound Imaging (UI) systems can be utilized for an RCT diagnosis. Although UI offers comparable performance at a lower cost to other diagnostic instruments such as MRI, speckle noise can occur the degradation of the image resolution. Conventional vision-based algorithms exhibit inferior performance for the segmentation of diseased regions in UI. In order to achieve a better segmentation for diseased regions in UI, deep-learning-based diagnostic algorithms have been developed. However, it has not yet reached an acceptable level of performance for application in orthopedic surgeries. In this study, we developed a novel end-to-end fully convolutional neural network, denoted as Segmentation Model Adopting a pRe-trained Classification Architecture (SMART-CA), with a novel integrated on positive loss function (IPLF) to accurately diagnose the locations of RCT during an orthopedic examination using UI. Using the pre-trained network, SMART-CA can extract remarkably distinct features that cannot be extracted with a normal encoder. Therefore, it can improve the accuracy of segmentation. In addition, unlike other conventional loss functions, which are not suited for the optimization of deep learning models with an imbalanced dataset such as the RCT dataset, IPLF can efficiently optimize the SMART-CA. Experimental results have shown that SMART-CA offers an improved precision, recall, and dice coefficient of 0.604% (+38.4%), 0.942% (+14.0%) and 0.736% (+38.6%) respectively. The RCT segmentation from a normal ultrasound image offers the improved precision, recall, and dice coefficient of 0.337% (+22.5%), 0.860% (+15.8%) and 0.484% (+28.5%), respectively, in the RCT segmentation from an ultrasound image with severe speckle noise. The experimental results demonstrated the IPLF outperforms other conventional loss functions, and the proposed SMART-CA optimized with the IPLF showed better performance than other state-of-the-art networks for the RCT segmentation with high robustness to speckle noise.

5 September 2022 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
HKHaemin Kim
Haemin Kim
SYSangyeon Youn
Sangyeon Youn
JKjinwoo kim
jinwoo kim
SPSunghun Park
Sunghun Park
MLMOONHWAN LEE
MOONHWAN LEE
Jin Ho ChangJin Ho Chang
Jin Ho Chang

25 July 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HLHaeyun Lee
Haeyun Lee
MLMOONHWAN LEE
MOONHWAN LEE
SYSangyeon Youn
Sangyeon Youn
KLKyungsu Lee
Kyungsu Lee
HLHah Min Lew
Hah Min Lew
JHJae Youn Hwang
Jae Youn Hwang
The performance of computer-aided diagnosis (CAD) systems that are based on ultrasound imaging has been enhanced owing to the advancement in deep learning. However, because of the inherent speckle noise in ultrasound images, the ambiguous boundaries of lesions deteriorate and are difficult to distinguish, resulting in the performance degradation of CAD. Although several methods have been proposed to reduce speckle noise over decades, this task remains a challenge that must be improved to enhance the performance of CAD. In this article, we propose a deep content-aware image prior (DCAIP) with a content-aware attention module (CAAM) for superior despeckling of ultrasound images without clean images. For the image prior, we developed a CAAM to deal with the content information in an input image. In this module, super-pixel pooling (SPP) is used to give attention to salient regions in an ultrasound image. Therefore, it can provide more content information regarding the input image when compared to other attention modules. The DCAIP consists of deep learning networks based on this attention module. The DCAIP is validated by applying it as a preprocessing step for breast tumor segmentation in ultrasound images, which is one of the tasks in CAD. Our method improved the segmentation performance by 15.89% in terms of the area under the precision–recall (PR) curve (AUPRC). The results demonstrate that our method enhances the quality of ultrasound images by effectively reducing speckle noise while preserving important information in the image, promising for the design of superior CAD systems.

5 January 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KLKyungsu Lee
Kyungsu Lee
MLMOONHWAN LEE
MOONHWAN LEE
DKDongho Kang
Dongho Kang
SKSewoong Kim
Sewoong Kim
Jin Ho ChangJin Ho Chang
Jin Ho Chang
JHJae Youn Hwang
Jae Youn Hwang
Accurate and continuous bladder volume monitoring is crucial for managing urinary dysfunctions. Wearable ultrasound devices offer a solution by enabling non-invasive and real-time monitoring. Previous studies have limitations in power consumption and computation cost or quantitative volume estimation capability. To alleviate this, we present a novel pipeline that effectively integrates conventional feature extraction and deep learning to achieve continuous quantitative bladder volume monitoring efficiently. Particularly, in the proposed pipeline, bladder shape is coarsely estimated by a simple bladder wall detection algorithm in wearable devices, and the bladder wall coordinates are wirelessly transferred to an external server. Subsequently, a roughly estimated bladder shape from the wall coordinates is refined in an external server with a diffusion-based model. With this approach, power consumption and computation costs on wearable devices remained low, while fully harnessing the potential of deep learning for accurate shape estimation. To evaluate the proposed pipeline, we collected a dataset of bladder ultrasound images and RF signals from 250 patients. By simulating data acquisition from wearable devices using the dataset, we replicated real-world scenarios and validated the proposed method within these scenarios. Experimental results exhibit superior improvements, including +9.32% of IoU value in 2D segmentation and -22.06 of RMSE in bladder volume regression compared to state-of-the-art performance from alternative methods, emphasizing the potential of this approach in continuous bladder volume monitoring in clinical settings. Therefore, this study effectively bridges the gap between accurate bladder volume estimation and the practical deployment of wearable ultrasound devices, promising improved patient care and quality of life.

1 January 2013 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
MLMOONHWAN LEE
MOONHWAN LEE
JHJung-Hong Ha
Jung-Hong Ha
MJMyoung-Uk Jin
Myoung-Uk Jin
YKYoung Kyung Kim
Young Kyung Kim
SKSung-Kyo Kim
Sung-Kyo Kim
Lee MH, et al. Restor Dent Endod. 2013 Nov;38(4):253-257. http://dx.doi.org/10.5395/rde.2013.38.4.253