Emilio Sánchez-Ortiga

Dr. Emilio Sánchez-Ortiga

Faculty of Physics, University of Valencia, Valencia, Spain

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
Ana DoblasAna Doblas
Ana Doblas
GSGenaro Saavedra
Genaro Saavedra
MMManuel Martinez-Corral
Manuel Martinez-Corral
JSJorge Garcia Sucerquia
Jorge Garcia Sucerquia
The utilization of microscope objectives (MOs) in digital holographic microscopy (DHM) has associated effects that are not present in conventional optical microscopy. The remaining phase curvature, which can ruin the quantitative phase imaging, is the most evident and analyzed. As phase imaging is considered, this interest has made possible the development of different methods of overcoming its undesired consequences. Additionally to the effects in phase imaging, there exist a set of less obvious conditions that have to be accounted for as MOs are utilized in DHM to achieve diffraction-limit operation. These conditions have to be considered even in the case in which only amplitude or intensity imaging is of interest. In this paper, a thorough analysis of the physical parameters that control the appropriate utilization of MOs in DHM is presented. A regular DHM system is theoretically modeled on the basis of the imaging theory. The Fourier spectrum of the recorded hologram is analyzed to evaluate the performance of the DHM. A set of the criteria that consider the microscope features and the recording parameters to achieve DHM operation at the diffraction limit is derived. Numerical modeling and experimental results are shown to validate our findings.

22 December 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
GSG. Scrofani
G. Scrofani
JSJ. Sola-Pikabea
J. Sola-Pikabea
ALA. Llavador
A. Llavador
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
JBJ. C. Barreiro
J. C. Barreiro
MMManuel Martinez-Corral
Manuel Martinez-Corral
In this work, Fourier integral microscope (FIMic), an ultimate design of 3D-integral microscopy, is presented. By placing a multiplexing microlens array at the aperture stop of the microscope objective of the host microscope, FIMic shows extended depth of field and enhanced lateral resolution in comparison with regular integral microscopy. As FIMic directly produces a set of orthographic views of the 3D-micrometer-sized sample, it is suitable for real-time imaging. Following regular integral-imaging reconstruction algorithms, a 2.75-fold enhanced depth of field and 2-time better spatial resolution in comparison with conventional integral microscopy is reported. Our claims are supported by theoretical analysis and experimental images of a resolution test target, cotton fibers, and in-vivo 3D-imaging of biological specimens.

1 April 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Ana DoblasAna Doblas
Ana Doblas
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
MMManuel Martinez-Corral
Manuel Martinez-Corral
GSGenaro Saavedra
Genaro Saavedra
JSJorge Garcia Sucerquia
Jorge Garcia Sucerquia
The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the microscope allows single-shot QPI in DHM by using telecentric imaging systems. Quantitative phase maps of a section of the head of the drosophila melanogaster fly and of red blood cells are obtained via single-shot DHM with no numerical postprocessing. With these maps we show that the use of telecentric DHM provides larger field of view for a given magnification and permits more accurate QPI measurements with less number of computational operations.

15 June 2011 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
PFPietro Ferraro
Pietro Ferraro
MMManuel Martinez-Corral
Manuel Martinez-Corral
GSGenaro Saavedra
Genaro Saavedra
Ana DoblasAna Doblas
Ana Doblas
Telecentric architecture is proposed for circumventing, by the pure-optical method, the residual parabolic phase distortion inherent to standard configuration of digital holographic microscopy. This optical circumvention produces several important advantages. One is that there is no need for computer compensation of the parabolic phase during the phase map recovering procedure. The other is that in off-axis configuration, the spatial frequency useful domain is enlarged. The validity of the method is demonstrated by performing quantitative measurement of depth differences with high axial resolution.

12 March 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SESamira Ebrahimi
Samira Ebrahimi
MDMasoomeh Dashtdar
Masoomeh Dashtdar
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
MMManuel Martinez-Corral
Manuel Martinez-Corral
BJBahram Javidi
Bahram Javidi
Digital holographic (DH) microscopy has grown into a powerful nondestructive technique for the real-time study of living cells including dynamic membrane changes and cell fluctuations in nanometer and sub-nanometer scales. The conventional DH microscopy configurations require a separately generated coherent reference wave that results in a low phase stability and a necessity to precisely adjust the intensity ratio between two overlapping beams. In this work, we present a compact, simple, and very stable common-path DH microscope, employing a self-referencing configuration. The microscope is implemented by a diode laser as the source and a Fresnel biprism for splitting and recombining the beams simultaneously. In the overlapping area, linear interference fringes with high contrast are produced. The frequency of the interference pattern could be easily adjusted by displacement of the biprism along the optical axis without a decrease in fringe contrast. To evaluate the validity of the method, the spatial noise and temporal stability of the setup are compared with the common off-axis DH microscope based on a Mach-Zehnder interferometer. It is shown that the proposed technique has low mechanical noise as well as superb temporal stability with sub-nanometer precision without any external vibration isolation. The higher temporal stability improves the capabilities of the microscope for studying micro-object fluctuations, particularly in the case of biological specimens. Experimental results are presented using red blood cells and silica microspheres to demonstrate the system performance.

30 March 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
Colin James Richard SheppardColin James Richard Sheppard
Colin James Richard Sheppard
GSGenaro Saavedra
Genaro Saavedra
MMManuel Martinez-Corral
Manuel Martinez-Corral
Ana DoblasAna Doblas
Ana Doblas
ACArnau Calatayud
Arnau Calatayud
We report a scheme for the detector system of confocal microscopes in which the pinhole and a large-area detector are substituted by a CCD camera. The numerical integration of the intensities acquired by the active pixels emulates the signal passing through the pinhole. We demonstrate the imaging capability and the optical sectioning of the system. Subtractive-imaging confocal microscopy can be implemented in a simple manner, providing superresolution and improving optical sectioning.