Masoomeh Dashtdar

Masoomeh Dashtdar


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SESamira Ebrahimi
Samira Ebrahimi
MDMasoomeh Dashtdar
Masoomeh Dashtdar
Emilio Sánchez-OrtigaEmilio Sánchez-Ortiga
Emilio Sánchez-Ortiga
MMManuel Martinez-Corral
Manuel Martinez-Corral
BJBahram Javidi
Bahram Javidi
Digital holographic (DH) microscopy has grown into a powerful nondestructive technique for the real-time study of living cells including dynamic membrane changes and cell fluctuations in nanometer and sub-nanometer scales. The conventional DH microscopy configurations require a separately generated coherent reference wave that results in a low phase stability and a necessity to precisely adjust the intensity ratio between two overlapping beams. In this work, we present a compact, simple, and very stable common-path DH microscope, employing a self-referencing configuration. The microscope is implemented by a diode laser as the source and a Fresnel biprism for splitting and recombining the beams simultaneously. In the overlapping area, linear interference fringes with high contrast are produced. The frequency of the interference pattern could be easily adjusted by displacement of the biprism along the optical axis without a decrease in fringe contrast. To evaluate the validity of the method, the spatial noise and temporal stability of the setup are compared with the common off-axis DH microscope based on a Mach-Zehnder interferometer. It is shown that the proposed technique has low mechanical noise as well as superb temporal stability with sub-nanometer precision without any external vibration isolation. The higher temporal stability improves the capabilities of the microscope for studying micro-object fluctuations, particularly in the case of biological specimens. Experimental results are presented using red blood cells and silica microspheres to demonstrate the system performance.

11 November 2019 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
SESamira Ebrahimi
Samira Ebrahimi
MDMasoomeh Dashtdar
Masoomeh Dashtdar
The structural complexity and instability of many interference phase microscopy methods are the major obstacles toward high-precision phase measurement. In this vein, improving more efficient configurations as well as proposing methods are the subjects of growing interest. Here, we introduce Fresnel diffraction from a phase step to the realm of quantitative phase imaging. By employing Fresnel diffraction of a divergent (or convergent) beam of light from a plane-parallel phase plate, we provide a viable, simple, and compact platform for three-dimensional imaging of micrometer-sized specimens. The recorded diffraction pattern of the outgoing light from an imaging system in the vicinity of the plate edge can be served as a hologram, which would be analyzed via the Fourier transform method to measure the sample phase information. The period of diffraction fringes is adjustable simply by rotating the plate without the reduction of both the field of view and fringe contrast. The high stability of the presented method is affirmatively confirmed through comparison of the result with that of the conventional Mach–Zehnder based digital holographic method. Quantitative phase measurements on silica microspheres, onion skins, and red blood cells ensure the validity of the method and its ability for monitoring nanometer-scale fluctuations of living cells, particularly in real-time.

9 September 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MDMasoomeh Dashtdar
Masoomeh Dashtdar
SHS. Mohammad-Ali Hosseini-Saber
S. Mohammad-Ali Hosseini-Saber
A method based on the Fresnel diffraction of light from the phase step is introduced for measuring effective focal length (EFL) and back focal length (BFL) of optical imaging systems. It is shown that, as a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. Variation of the incident angle in a convergent (or divergent) beam of light causes the periodic intensity along the central fringe of the diffraction pattern. The measurement of the extrema position of the intensity distribution accurately provides the EFL and BFL. The technique is easy to apply and can measure a wide range of both positive and negative focal lengths. The measuring setup can be very compact with low mechanical and optical noises. As examples of this technique, the EFLs of five different lenses are experimentally obtained. The results are quite consistent with the values indicated by the lens manufacturer.

19 July 2021 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SESamira Ebrahimi
Samira Ebrahimi
MDMasoomeh Dashtdar
Masoomeh Dashtdar
In this Letter, a very simple, stable, and portable lensless digital holographic (DH) microscopy method is presented relying on the Fresnel diffraction (FD) of light from a phase discontinuity (PD). A phase plate in the transmission or a physical step in the reflection can be employed in the path of the divergent beam of a coherent light source as a component imposing the PD. The recorded diffraction pattern in the vicinity of the PD is a hologram produced by off-axis overlapping of two diffracted waves in both sides of the boundary region with adjustable fringe modulation. To validate the method, measurements are performed on the amplitude and phase specimens as well as on the dynamic processes of water evaporation and 3D tracking of floating cells. A reflective configuration of FD from a physical step can be used as a powerful platform for lensless DH microscopy using high-energy electromagnetic radiation, e.g., x-ray and UV sources for the high-resolution imaging of moving samples.

27 August 2019 in Open Chemistry
Verified
Journal Article
Open access
AYAhmadreza Yazdanbakhsh
Ahmadreza Yazdanbakhsh
RNReza Nemati
Reza Nemati
MMMohamadreza Massoudinejad
Mohamadreza Massoudinejad
MJMohamadjavad Jafari
Mohamadjavad Jafari
MDMasoomeh Dashtdar
Masoomeh Dashtdar
The primary purpose of this study was to investigate the efficiency of a Compound Parabolic Concentrator (CPC) equipped with a sun tracking system in the photolysis of carbamazepine as a refractory organic compound. The natural sunlight experiments were accomplished during the period May–July 2017 in Tehran, Iran. The intermediate by-products of the process of solar photodegradation of carbamazepine (CBZ) were characterized using LC–MS. The results showed that increasing the reactor temperature did not significantly change CBZ degradation efficiency. However, the solution pH played a comparatively important role in CBZ solar photo degradation: removal efficiency increased considerably with pH from about 49% at pH 7 to almost 61% at pH 9. According to our findings, using a CPC reactor equipped with a sun tracker system promotes the solar photo-transformation rate of CBZ by 2-3 fold. In addition, LC/MS analysis showed that eight main intermediates were formed in the treated solution after solar photodegradation of CBZ. Therefore, complete mineralization of CBZ was not accomplished.

1 May 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HNHasti Nourzadeh
Hasti Nourzadeh
MLMaryam Lotfi
Maryam Lotfi
Humberto CabreraHumberto Cabrera
Humberto Cabrera
Maria Liz CrespoMaria Liz Crespo
Maria Liz Crespo
MDMasoomeh Dashtdar
Masoomeh Dashtdar
We report a highly stable and affordable dual-wavelength digital holographic microscopy system based on common-path geometry. A Fresnel biprism is used to create an off-axis geometry, and two diode laser sources with different wavelengths λ1 = 532 nm and λ2 = 650 nm generate the dual-wavelength compound hologram. In order to extend the measurement range, the phase distribution is obtained using a synthetic wavelength Λ1 = 2930.5 nm. Furthermore, to improve the system's temporal stability and reduce speckle noise, a shorter wavelength (Λ2 = 292.5 nm) is used. The feasibility of the proposed configuration is validated by the experimental results obtained with Molybdenum trioxide, Paramecium, and red blood cell specimens.