Sunam Kumar Sharma

Mr. Sunam Kumar Sharma

Jeju National University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
SKSravan Kumar Konki
Sravan Kumar Konki
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
KKKyung Youn Kim
Kyung Youn Kim
The noninvasive method for monitoring urine collection in the bladder is highly recommended for paraplegia patients. These patients are unable to discharge urine at the right time due to a weaker sensation for bladder volume. If the urine is not discharged in time, then the bladder size will increase and affect the neighboring organs and tissues. Electrical impedance tomography (EIT) is a noninvasive alternative method that can be used for bladder status monitoring. Size estimation of the bladder with EIT can clarify the bladder status. The bladder is a nonuniform structure with complex shape; therefore, higher order Fourier series is needed to represent the true shape. In estimating the higher order Fourier coefficients, the performance of a conventional modified Newton-Raphson (mNR) algorithm does not give the desired performance. In this article, the gravitational search algorithm (GSA) that is known for solving optimization problems in high-dimensional search space is proposed for the shape estimation of the bladder. GSA is a global optimization algorithm that has fast convergence and does not require the computation of Jacobian. Numerical experiments and phantom studies are performed to estimate the bladder size, and the results showed good performance.

1 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
SRSheik Abdur Rahman
Sheik Abdur Rahman
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
WKWoo Young Kim
Woo Young Kim
KKKyung Youn Kim
Kyung Youn Kim
Recently, graphene has gained a lot of attention in the electronic industry due to its unique properties and has paved the way for realizing novel devices in the field of electronics. For the development of new device applications, it is necessary to grow large wafer-sized monolayer graphene samples. Among the methods to synthesize large graphene films, chemical vapor deposition (CVD) is one of the promising and common techniques. However, during the growth and transfer of the CVD graphene monolayer, defects such as wrinkles, cracks, and holes appear on the graphene surface. These defects can influence the electrical properties and it is of interest to know the quality of graphene samples non-destructively. Electrical impedance tomography (EIT) can be applied as an alternate method to determine conductivity distribution non-destructively. The EIT inverse problem of reconstructing conductivity is highly non-linear and is heavily dependent on measurement accuracy and modeling errors related to an accurate knowledge of electrode location, contact resistances, the exact outer boundary of the graphene wafer, etc. In practical situations, it is difficult to eliminate these modeling errors as complete knowledge of the electrode contact impedance and outer domain boundary is not fully available, and this leads to an undesirable solution. In this paper, a difference imaging approach is proposed to estimate the conductivity change of graphene with respect to the reference distribution from the data sets collected before and after the change. The estimated conductivity change can be used to locate the defects on the graphene surface caused due to the CVD transfer process or environment interaction. Numerical and experimental results with graphene sample of size 2.5 × 2.5 cm are performed to determine the change in conductivity distribution and the results show that the proposed difference imaging approach handles the modeling errors and estimates the conductivity distribution with good accuracy.

1 November 2020 in Physiological Measurement
Verified
Journal Article
Closed access
SKS K Konki
S K Konki
AKA K Khambampati
A K Khambampati
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
KKKyung Youn Kim
Kyung Youn Kim
Objective : Accurate bladder size estimation is an important clinical parameter that assists physicians, enabling them to provide better treatment for patients who are suffering from urinary incontinence. Electrical impedance tomography (EIT) is a non-invasive medical imaging method that estimates organ boundaries assuming that the electrical conductivity values of the background, bladder, and adjacent tissues inside the pelvic domain are known a priori . However, the performance of a traditional EIT inverse algorithm such as the modified Newton–Raphson (mNR) for shape estimation exhibits severe convergence problems as it heavily depends on the initial guess and often fails to estimate complex boundaries that require greater numbers of Fourier coefficients to approximate the boundary shape. Therefore, in this study a deep neural network (DNN) is introduced to estimate the urinary bladder boundary inside the pelvic domain. Approach : We designed a five-layer DNN which was trained with a dataset of 15 subjects that had different pelvic boundaries, bladder shapes, and conductivity. The boundary voltage measurements of the pelvic domain are defined as input and the corresponding Fourier coefficients that describe the bladder boundary as output data. To evaluate the DNN, we tested with three different sizes of urinary bladder. Main results : Numerical simulations and phantom experiments were performed to validate the performance of the proposed DNN model. The proposed DNN algorithm is compared with the radial basis function (RBF) and mNR method for bladder shape estimation. The results show that the DNN has a low root mean square error for estimated boundary coefficients and better estimation of bladder size when compared to the mNR and RBF. Significance : We apply the first DNN algorithm to estimate the complex boundaries such as the urinary bladder using EIT. Our work provides a novel efficient EIT inverse solver to estimate the bladder boundary and size accurately. The proposed DNN algorithm has advantages in that it is simple to implement, and has better accuracy and fast estimation.

3 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
SRSheik Abdur Rahman
Sheik Abdur Rahman
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
WKWoo Young Kim
Woo Young Kim
KKKyung Youn Kim
Kyung Youn Kim
Single-layer graphene synthesized using the chemical vapor deposition (CVD) technique contains defects on the graphene surface that are formed during the growth and transfer process. These defects influence the graphene electrical characteristics, especially the conductivity distribution. Nondestructive characterization of graphene samples is therefore essential for developing single-layer graphene devices. Electrical impedance tomography (EIT), a low-cost nondestructive method with high temporal resolution characteristics, can be applied to obtain the local conductivity distribution. Due to the very high conductivity of the background and inaccurate knowledge of contact impedances, the conventional absolute imaging methods do not give desired conductivity reconstruction for graphene. This study uses a nonlinear difference imaging (NDI) approach to estimate the local conductivity changes across the graphene surface quantitatively. In NDI, the conductivity after the change is parameterized as a linear combination of initial and the conductivity change. The conductivity change restricted to the region of interest (ROI) is determined using the Otsu method. The NDI with Otsu method (NDIWO) estimates the initial distribution and conductivity changes simultaneously from the two datasets measured at different time intervals. NDIWO tolerates modeling errors to some extent and quantitively provides more accurate local conductivity changes. The feasibility of NDIWO is tested with numerical simulations and experiments with graphene wafer of size 2.5 cm $\times2.5$ cm, and results show that the proposed method is successful in estimating the conductivity changes with better accuracy than conventional absolute and linear difference imaging.

30 September 2022 in IEEE Access
Verified
Journal Article
Open access
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
KKKyung Youn Kim
Kyung Youn Kim
Recently, graphene has gained a lot of attention in the electronic industry due to its unique properties and to overcome the limits of miniaturization making way for novel devices in the field of electronics. Among the synthesizing methods for growing large graphene films, chemical vapour deposition is one of the promising and common techniques but defects such as cracks, holes, or wrinkles are hard to avoid. The presence of defects influence the electrical properties of graphene thus the local conductivity distribution across the surface of the graphene can characterize its electrical behavior. The difference in conductivity values of the defect and the background can be estimated with electrical impedance tomography. Due to the very high conductivity of graphene, the reconstructed electrical impedance tomography conductivity images suffer from poor spatial resolution. Considering the graphene defect conductivity and the number of defects are known a priori then the unknowns are defect geometry and background conductivity of graphene that are estimated using hybrid particle swarm optimization - gravitational search algorithm. The defect geometries are described by truncated Fourier series coefficient which can represent the complex shapes. Numerical studies are done for graphene characterization with single and multiple defects. Monte Carlo simulations with 20 runs having different noise seed are carried out to evaluate the robustness of the proposed algorithm. Statistical analysis is done and the results of the proposed algorithm are compared against the conventional modified Newton Raphson method and gravitational search algorithm. Experimental studies with graphene sheet 2.5 cm $\times2.5$ cm with defects are performed for shape estimation. The results showed that the proposed algorithm has a good estimation of background conductivity and defect geometry.

1 October 2018
Verified
Conference Paper
Closed access
AKA. K. Khambampati
A. K. Khambampati
SKS. K. Konki
S. K. Konki
YHY. J. Han
Y. J. Han
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
KKK. Y. Kim
K. Y. Kim
Patients suffering with neurogenic dysfunction lack urinary consciousness therefore it is necessary to know about the urine volume inside bladder for determining the time for emptying. As the amount of urine collected in bladder increases the size of the bladder increases and it displaces the neighboring tissues. It is necessary to find an efficient method that can be used continuously for long periods to determine the bladder volume. In this paper a non-invasive electrical impedance tomography (EIT) imaging method to monitor the condition of human bladder using electrical impedance tomography is presented. The forward problem of EIT is solved using boundary element method while the inverse problem of estimating the size and shape of bladder is done with Levenberg-Marquardt method. Numerical simulations with pelvis shaped domain are carried out to evaluate the feasibility of the proposed method.