Sheik Abdur Rahman

Mr. Sheik Abdur Rahman

Jeju National University, South Korea
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SRSheik Abdur Rahman
Sheik Abdur Rahman
SKShenawar Ali Khan
Shenawar Ali Khan
Muhammad Muqeet RehmanMuhammad Muqeet Rehman
Muhammad Muqeet Rehman
WKWoo Young Kim
Woo Young Kim
Two-dimensional (2D) materials and their composites have gained significant importance as the functional layer of various environmental sensors and nanoelectronics owing to their unique properties. This work reports for the first time a highly sensitive, fast, and stable humidity sensor based on the bi-layered active sensing area composed of graphene flower (GF) and poly (vinyl alcohol) PVA thin films for multifunctional applications. The GF/PVA humidity sensor exhibited stable impedance response over 15 days, for a relative humidity (RH) range of (40–90% RH) under ambient operating conditions. The proposed bi-layered humidity sensor also exhibited an ultra-high capacitive sensitivity response of the 29 nF/%RH at 10 kHz and fast transient response of 2 s and 3.5 s, respectively. Furthermore, the reported sensor also showed a good response towards multi-functional applications such as non-contact skin humidity and mouth breathing detection.

26 July 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SKShenawar Ali Khan
Shenawar Ali Khan
MSMuhammad Saqib
Muhammad Saqib
Muhammad Muqeet RehmanMuhammad Muqeet Rehman
Muhammad Muqeet Rehman
Hafiz Mohammad Mutee Ur RehmanHafiz Mohammad Mutee Ur Rehman
Hafiz Mohammad Mutee Ur Rehman
SRSheik Abdur Rahman
Sheik Abdur Rahman
WKWoo Young Kim
Woo Young Kim
A novel composite based on a polymer (P(VDF-TrFE)) and a two-dimensional material (graphene flower) was proposed as the active layer of an interdigitated electrode (IDEs) based humidity sensor. Silver (Ag) IDEs were screen printed on a flexible polyethylene terephthalate (PET) substrate followed by spin coating the active layer of P(VDF-TrFE)/graphene flower on its surface. It was observed that this sensor responds to a wide relative humidity range (RH%) of 8–98% with a fast response and recovery time of 0.8 s and 2.5 s for the capacitance, respectively. The fabricated sensor displayed an inversely proportional response between capacitance and RH%, while a directly proportional relationship was observed between its impedance and RH%. P(VDF-TrFE)/graphene flower-based flexible humidity sensor exhibited high sensitivity with an average change of capacitance as 0.0558 pF/RH%. Stability of obtained results was monitored for two weeks without any considerable change in the original values, signifying its high reliability. Various chemical, morphological, and electrical characterizations were performed to comprehensively study the humidity-sensing behavior of this advanced composite. The fabricated sensor was successfully used for the applications of health monitoring and measuring the water content in the environment.

13 July 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Hafiz Mohammad Mutee Ur RehmanHafiz Mohammad Mutee Ur Rehman
Hafiz Mohammad Mutee Ur Rehman
Muhammad Muqeet RehmanMuhammad Muqeet Rehman
Muhammad Muqeet Rehman
MSMuhammad Saqib
Muhammad Saqib
SKShenawar Ali Khan
Shenawar Ali Khan
MKMaryam Khan
Maryam Khan
WKWoo Young Kim
Woo Young Kim
Biopolymers are a solution to solve the increasing problems caused by the advances and revolution in the electronic industry owing to the use of hazardous chemicals. In this work, we have used egg white (EW) as the low-cost functional layer of a biocompatible humidity sensor and deposited it on gold (Au) interdigitated electrodes (IDEs) patterned through the state-of-the-art fabrication technology of thermal vacuum evaporation. The presence of hydrophilic proteins inside the thin film of EW makes it an attractive candidate for sensing humidity. Usually, the dependence of the percentage of relative humidity (%RH) on the reliability of measurement setup is overlooked for impedimetric humidity sensors but we have used a modified experimental setup to enhance the uniformity of the obtained results. The characteristics of our device include almost linear response with a quick response time (1.2 s) and fast recovery time (1.7 s). High sensitivity of 50 kΩ/%RH was achieved in the desirable detection range of 10–85%RH. The device size was intentionally kept small for its potential integration in a marketable chip. Results for the response of our fabricated sensor for dry and wet fingertips, along with determining the rate of breathing through the mouth, are part of this study, making it a potential device for health monitoring.

15 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SRSheik Abdur Rahman
Sheik Abdur Rahman
SKShenawar Ali Khan
Shenawar Ali Khan
Shahzad IqbalShahzad Iqbal
Shahzad Iqbal
Muhammad Muqeet RehmanMuhammad Muqeet Rehman
Muhammad Muqeet Rehman
WKWoo Young Kim
Woo Young Kim
Biomaterials offer great potential for enhancing the performance of humidity sensors, which play a critical role in controlling moisture levels across different applications. By utilizing environmentally friendly, sustainable, and cost-effective biomaterials, we can improve the manufacturing process of these sensors while reducing our environmental impact. In this study, we present a high-performance humidity sensor that utilizes purple sweet potato peel (PSPP) as both the substrate and sensing layer. The PSPP is chosen for its polar hydrophilic functional groups, as well as its environmentally friendly nature, sustainability, and cost-effectiveness. Remarkably, this humidity sensor does not require an external substrate. It exhibits a wide detection range of 0 to 85% relative humidity at various operating frequencies (100 Hz, 1 kHz, and 10 kHz) in ambient temperature, demonstrating its effectiveness in responding to different humidity levels. The sensor achieves a high sensitivity value of 183.23 pF/%RH and minimal hysteresis of only 5% at 10 kHz under ambient conditions. It also boasts rapid response and recovery times of 1 and 2 s, respectively, making it suitable for use in high-end electronic devices. Moreover, the sensor’s applications extend beyond environmental monitoring. It has proven effective in monitoring mouth and nasal breathing, indicating its potential for respiratory monitoring and noncontact proximity response. These findings suggest that sweet potato peel material holds great promise as a highly stable, non-toxic, biodegradable, cost-effective, and environmentally friendly option for various domains, including healthcare monitoring.

1 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
SRSheik Abdur Rahman
Sheik Abdur Rahman
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
WKWoo Young Kim
Woo Young Kim
KKKyung Youn Kim
Kyung Youn Kim
Recently, graphene has gained a lot of attention in the electronic industry due to its unique properties and has paved the way for realizing novel devices in the field of electronics. For the development of new device applications, it is necessary to grow large wafer-sized monolayer graphene samples. Among the methods to synthesize large graphene films, chemical vapor deposition (CVD) is one of the promising and common techniques. However, during the growth and transfer of the CVD graphene monolayer, defects such as wrinkles, cracks, and holes appear on the graphene surface. These defects can influence the electrical properties and it is of interest to know the quality of graphene samples non-destructively. Electrical impedance tomography (EIT) can be applied as an alternate method to determine conductivity distribution non-destructively. The EIT inverse problem of reconstructing conductivity is highly non-linear and is heavily dependent on measurement accuracy and modeling errors related to an accurate knowledge of electrode location, contact resistances, the exact outer boundary of the graphene wafer, etc. In practical situations, it is difficult to eliminate these modeling errors as complete knowledge of the electrode contact impedance and outer domain boundary is not fully available, and this leads to an undesirable solution. In this paper, a difference imaging approach is proposed to estimate the conductivity change of graphene with respect to the reference distribution from the data sets collected before and after the change. The estimated conductivity change can be used to locate the defects on the graphene surface caused due to the CVD transfer process or environment interaction. Numerical and experimental results with graphene sample of size 2.5 × 2.5 cm are performed to determine the change in conductivity distribution and the results show that the proposed difference imaging approach handles the modeling errors and estimates the conductivity distribution with good accuracy.

3 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Anil Kumar KhambampatiAnil Kumar Khambampati
Anil Kumar Khambampati
SRSheik Abdur Rahman
Sheik Abdur Rahman
Sunam Kumar SharmaSunam Kumar Sharma
Sunam Kumar Sharma
WKWoo Young Kim
Woo Young Kim
KKKyung Youn Kim
Kyung Youn Kim
Single-layer graphene synthesized using the chemical vapor deposition (CVD) technique contains defects on the graphene surface that are formed during the growth and transfer process. These defects influence the graphene electrical characteristics, especially the conductivity distribution. Nondestructive characterization of graphene samples is therefore essential for developing single-layer graphene devices. Electrical impedance tomography (EIT), a low-cost nondestructive method with high temporal resolution characteristics, can be applied to obtain the local conductivity distribution. Due to the very high conductivity of the background and inaccurate knowledge of contact impedances, the conventional absolute imaging methods do not give desired conductivity reconstruction for graphene. This study uses a nonlinear difference imaging (NDI) approach to estimate the local conductivity changes across the graphene surface quantitatively. In NDI, the conductivity after the change is parameterized as a linear combination of initial and the conductivity change. The conductivity change restricted to the region of interest (ROI) is determined using the Otsu method. The NDI with Otsu method (NDIWO) estimates the initial distribution and conductivity changes simultaneously from the two datasets measured at different time intervals. NDIWO tolerates modeling errors to some extent and quantitively provides more accurate local conductivity changes. The feasibility of NDIWO is tested with numerical simulations and experiments with graphene wafer of size 2.5 cm $\times2.5$ cm, and results show that the proposed method is successful in estimating the conductivity changes with better accuracy than conventional absolute and linear difference imaging.